ABIM Critical Care study materials
ABIM Critical Care study resources

Weaning Failure in a Patient with COPD and Auto-PEEP

ABIM Critical Care · Put your knowledge to work in context.

All case studies

Weaning Failure in a Patient with COPD and Auto-PEEP

A 68-year-old man with GOLD stage 3 COPD is on day 4 of mechanical ventilation for a COPD exacerbation. He is sedated with propofol 30 mcg/kg/min, awake and following commands, afebrile, with clear secretions. Settings: volume-control, tidal volume 500 mL, PEEP 8 cmH2O, FiO2 0.35, rate 14. ABG: pH 7.30, PaCO2 58 mmHg, PaO2 78 mmHg. Plateau pressure is 28 cmH2O and peak pressure 42 cmH2O. A spontaneous breathing trial on pressure support 8 cmH2O/PEEP 5 is attempted; after 25 minutes his respiratory rate rises from 18 to 34, he becomes diaphoretic and agitated, and his SpO2 falls from 97% to 89%. He is placed back on full support.

1. Interpret the pre-SBT respiratory mechanics and identify the most likely cause of his failed spontaneous breathing trial.

Read the worked answer

The key finding is the plateau–peak pressure gap: plateau 28 with peak 42 means a resistive gradient of ~14 cmH2O, while the plateau itself (28) is elevated. In a COPD patient the most likely contributors are dynamic hyperinflation with intrinsic PEEP (auto-PEEP) and increased airways resistance.

Reasoning chain:

  • Auto-PEEP raises the effective threshold the patient must overcome to trigger a breath and to generate tidal volume during spontaneous effort; it also increases work of breathing and worsens dyspnea.
  • The failed SBT with tachypnea, diaphoresis, and desaturation is the classic load–capacity mismatch of weaning failure, not simply hypoxemia (PaO2 was acceptable).
  • The pH 7.30/PaCO2 58 reflects his permissive hypercapnia baseline but also hints at inadequate expiratory time.

Next step is to measure end-expiratory hold (total PEEP minus set PEEP = auto-PEEP) and reduce dynamic hyperinflation: lower set rate, increase expiratory time, treat bronchospasm, and avoid over-distension.

2. List three concrete ventilator or pharmacologic changes you would make before the next weaning attempt, and justify each.

Read the worked answer
  1. Prolong expiratory time / reduce dynamic hyperinflation - lower set rate (e.g., 10–12) and/or reduce tidal volume toward 6 mL/kg predicted body weight, accepting higher PaCO2 if pH tolerates. This reduces air trapping and auto-PEEP, lowering the work of triggering.
  2. Optimize bronchodilators and airway clearance - scheduled inhaled short-acting beta-agonist/anticholinergic and chest physiotherapy; reducing resistance lowers the resistive pressure gradient and work of breathing.
  3. Match PEEP to auto-PEEP during the SBT - applying external PEEP close to measured intrinsic PEEP (e.g., 5–8) reduces the inspiratory threshold load and trigger work; do not exceed it or you worsen hyperinflation. Also ensure adequate nutrition and treat any electrolyte issues (e.g., hypophosphatemia, hypokalemia) that impair diaphragm strength.

Reassess with an end-expiratory hold and repeat SBT when the patient is stable, ideally with a T-piece or low-level pressure support.