ASE H1 CNG Engines (Transit Bus) · Put your knowledge to work in context.

All case studies

CNG Pressure Regulator Freezing

A dedicated CNG bus experiences a loss of power and rough running after 30 minutes of operation in cold weather (ambient 20°F). The technician notices the pressure regulator is covered in frost. The bus has a 3600 psi storage system. The regulator is a two-stage design with an integrated heat exchanger. Coolant lines to the regulator are warm to the touch. The fuel pressure at the regulator inlet is 3600 psi, and outlet pressure to the injectors is 120 psi (spec is 90-110 psi). The engine has a turbocharger and is equipped with a wideband oxygen sensor. No DTCs are set, but fuel trims are +25% (lean). The bus has 80,000 miles. The coolant level is full and the thermostat is working.

1. What is the likely cause of the frost and lean condition, and how does it relate to the pressure regulator?

Read the worked answer

The frost on the regulator indicates that the regulator is not receiving enough heat to counteract the cooling effect of expanding CNG from 3600 psi to 120 psi. This is a Joule-Thomson effect: gas cools as it expands. The regulator uses engine coolant to warm the gas. Although the coolant lines are warm, the heat exchanger inside the regulator may be clogged or the coolant flow may be restricted. The outlet pressure is 120 psi, which is higher than spec, suggesting the regulator is not regulating properly, possibly due to internal damage or icing. The lean condition (+25% fuel trims) could be because the higher pressure causes the injectors to deliver more fuel? Actually, higher pressure would richen the mixture, but the lean condition suggests that the regulator may be supplying insufficient fuel due to icing or a stuck valve. Alternatively, the frost could be from moisture in the gas freezing and blocking the regulator. The technician should check for coolant flow through the regulator and inspect the heat exchanger. Also, check for a restricted return line or a faulty regulator. The regulator may need replacement.

2. What diagnostic steps should the technician take to confirm the cause?

Read the worked answer

First, verify coolant flow through the regulator by checking inlet and outlet hose temperatures; a large temperature drop indicates restricted flow. Remove the regulator and inspect the heat exchanger for clogging or scale. Check the coolant for proper mixture and condition. Test the regulator on a bench if possible, or replace with a known-good unit. Also, check for moisture in the CNG by inspecting the high-pressure filter for water. If water is present, the gas may be wet, causing ice formation. Additionally, check the pressure regulator's outlet pressure with a known-good gauge; if it remains high, the regulator is faulty. After repair, verify fuel trims return to normal and no frost forms.