First 50 of 200 questions. Each one lists the choices, the correct answer, and an explanation. The checker at the top of this page saves progress in this browser when it is available.
Continue in the practice tool above to load more questions, 50 at a time.
Question 1High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Which color identifies high-voltage conductors and cables on most automotive high-voltage systems?
- Red
- Orange Correct answer.
- Green with a yellow stripe
- Blue
Explanation
High-voltage cabling is marked with orange loom or orange conductor insulation so technicians can identify it before any service work begins. The color is a warning convention, not a circuit function indicator, so voltage must still be verified with a meter. Red, blue, and green/yellow are used for conventional low-voltage circuits and grounds.
Question 2High-Voltage Safety, Personal Protective Equipment, and Service Procedures
At what voltage is a circuit generally treated as high voltage in automotive service?
- 60 V DC or 30 V AC RMS Correct answer.
- 240 V DC or 120 V AC RMS
- 30 V DC or 15 V AC RMS
- 120 V DC or 60 V AC RMS
Explanation
Automotive high-voltage systems are defined as exceeding 60 volts DC or 30 volts AC RMS. Above these values the potential for harmful body current exists, so insulated tools, gloves, and lockout procedures are required. Systems below the threshold are handled with normal 12-volt precautions.
Question 3High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Before beginning work on an energized high-voltage system, a technician should remove which item?
- Cotton work shirt
- Insulating gloves
- Safety glasses
- Metal jewelry Correct answer.
Explanation
Rings, watches, and chains are conductive and can create a low-resistance path to ground or bridge a live terminal. Jewelry is removed before any high-voltage task and stored away from the work area. Safety glasses and insulating gloves are required PPE and stay on.
Question 4High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Which practice is required when performing energized high-voltage diagnostics?
- Wearing only one glove for dexterity
- A second trained person present Correct answer.
- Disabling the vehicle horn
- Working with the shop doors closed
Explanation
Energized high-voltage work requires a second trained person who can de-energize the system and summon help if the technician is incapacitated. This person must know the location of the service disconnect and the rescue equipment. Working alone removes the ability to be rescued quickly.
Question 5High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Insulated hand tools used on high-voltage systems should carry which voltage rating?
- No rating is required
- 1,000 V Correct answer.
- 10,000 V
- 100 V
Explanation
Insulated tools are marked with a dielectric rating, commonly 1,000 volts, that must meet or exceed the circuit voltage. Tools without a marked rating, or with damaged insulation, are not used on high-voltage systems. The rating applies only when the insulation is intact.
Question 6High-Voltage Safety, Personal Protective Equipment, and Service Procedures
How is an air test performed on rubber insulating gloves?
- Fill the glove with water and watch for leaks at the fingertips
- Stretch the glove over a grounded rod and check the meter reading
- Inflate the glove with shop air and listen for a hiss
- Roll the cuff tightly to trap air and check for escaping air Correct answer.
Explanation
The air test traps air inside the glove by rolling the cuff, then the technician watches and feels for escaping air, especially at the fingers and seams. Any leak indicates a puncture and the glove is removed from service. The test is combined with a close visual inspection before each use.
Question 7High-Voltage Safety, Personal Protective Equipment, and Service Procedures
What face protection is appropriate when working near an energized high-voltage battery pack?
- A welding helmet with a dark lens
- Sunglasses with UV lenses
- Face shield over safety glasses Correct answer.
- A dust mask only
Explanation
A face shield worn over safety glasses protects against electrolyte spray, arc flash, and flying debris while preserving clear vision. Safety glasses alone leave the face exposed, and a welding lens is too dark for general work. The face shield is an addition to, not a replacement for, primary eye protection.
Question 8High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Rubber insulating gloves must receive a visual inspection and air test at which interval?
- Every 12 months with the vehicle service
- Once per year
- Before each use Correct answer.
- Only when first issued
Explanation
Gloves are inspected visually and air tested before every use because damage can occur between jobs or during storage. Electrical retesting by a laboratory is a separate requirement on a longer interval. A glove that fails inspection is destroyed or returned for testing, never used.
Question 9High-Voltage Safety, Personal Protective Equipment, and Service Procedures
A rubber insulating glove marked Class 0 is rated for use up to which maximum AC voltage?
- 1,000 V Correct answer.
- 7,500 V
- 17,000 V
- 500 V
Explanation
Class 0 gloves carry a maximum use voltage of 1,000 volts AC, which covers automotive high-voltage buses. Class 00 is rated to 500 volts and Class 1 to 7,500 volts. The class marking must be checked against the system voltage before work begins.
Question 10High-Voltage Safety, Personal Protective Equipment, and Service Procedures
In-service rubber insulating gloves must be electrically retested at intervals not exceeding:
- 6 months Correct answer.
- 24 months
- 12 months
- 30 days
Explanation
Rubber insulating gloves in service are electrically retested at a laboratory at least every six months. Retesting verifies that the dielectric strength has not degraded from use, cleaning, or storage. Gloves past their retest date are removed from service until tested.
Question 11High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Which sequence is correct when disabling a high-voltage system for service?
- Remove the disconnect, wait the stated time, then verify no voltage Correct answer.
- Verify no voltage, remove the disconnect, then wait the stated time
- Wait the stated time, remove the disconnect, then verify no voltage
- Remove the disconnect, verify no voltage, then wait the stated time
Explanation
The disconnect is removed first to open the high-voltage contacts, then the specified wait lets capacitors bleed down, and only then is absence of voltage verified with a meter. Verifying before the wait can give a false reading from stored energy. Locking out the disconnect after removal prevents reconnection during the job.
Question 12High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Why must a specified waiting period be observed after the high-voltage service disconnect is removed?
- To let the battery management system reset
- To let inverter capacitors discharge Correct answer.
- To allow the coolant to stop circulating
- To permit the contactors to cool
Explanation
Inverter and converter DC bus capacitors can hold a lethal charge after the battery contacts open, and the wait period allows them to bleed down. Only after the wait is absence of voltage verified. Contactors and coolant have no bearing on residual voltage.
Question 13High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Which category rating is appropriate for a multimeter used to measure voltage on an automotive high-voltage bus?
- CAT III Correct answer.
- CAT IV
- CAT I
- CAT II
Explanation
CAT III meters are rated to withstand the transient overvoltages and available energy found on distribution-level circuits, which is the closest match for an automotive traction bus. CAT I and CAT II meters lack the transient withstand needed. The voltage rating of the meter must also meet or exceed the system voltage.
Question 14High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Which test instrument is used to check the insulation resistance of a high-voltage cable?
- A megohmmeter Correct answer.
- A lab scope
- A clamp-on ammeter
- A circuit tester
Explanation
A megohmmeter applies a high test voltage and measures leakage to determine insulation resistance in megohms. Low readings indicate damaged or contaminated insulation. A clamp ammeter, scope, or test light cannot measure insulation quality.
Question 15High-Voltage Safety, Personal Protective Equipment, and Service Procedures
What is the purpose of equipotential bonding when working on a high-voltage vehicle?
- To keep conductive parts at the same potential Correct answer.
- To speed up charging of the high-voltage pack
- To discharge the pack before any service is started
- To isolate the technician from earth ground completely
Explanation
Equipotential bonding connects conductive parts so they sit at the same potential, eliminating voltage differences that could drive current through a person. It does not de-energize anything or isolate the technician. The bond must be made before work and removed in the correct order.
Question 16High-Voltage Safety, Personal Protective Equipment, and Service Procedures
A non-conductive rescue hook is kept at a high-voltage work area to:
- Support the weight of the HV cable during removal
- Discharge static electricity from the technician
- Pull a technician clear of an energized conductor Correct answer.
- Test the circuit for voltage before any contact is made
Explanation
The rescue hook lets a second person move a technician away from a live conductor without touching them or becoming part of the circuit. It is not a voltage tester or a lifting device. The rescuer should also de-energize the system as soon as it is safe to do so.
Question 17High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Why is a voltage tester proved on a known live source before and after checking a de-energized circuit?
- To check meter battery level
- To prove the tester works Correct answer.
- To discharge the circuit capacitance
- To measure insulation resistance
Explanation
Proving the tester on a known source before and after the measurement confirms it was functional at the moment the de-energized circuit was checked. A failed meter or test lead can read zero on a live circuit. This live-dead-live sequence is the standard verification method.
Question 18High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Which clothing choice is correct for high-voltage work where an arc flash hazard exists?
- A nylon windbreaker worn for splash protection over jeans
- Arc-rated clothing over non-melting base layers Correct answer.
- A cotton shirt under a plastic rain coat and rubber boots
- A polyester coverall worn over cotton underwear and a hard hat
Explanation
Arc-rated clothing is tested to resist ignition and break open rather than melt into the skin. Meltable synthetics next to the skin worsen burn injuries and are avoided. Rain gear and windbreakers are not arc rated and can melt under arc exposure.
Question 19High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Which observation suggests a high-voltage battery may be entering thermal runaway?
- Pack case swelling with a sweet odor Correct answer.
- A slight drop in pack voltage during a road test
- Normal coolant temperature with a low state of charge
- A steady 12-volt charging voltage at idle
Explanation
Case swelling, venting, a sweet or solvent-like smell, and rising temperature are early signs of cell thermal runaway. The area should be evacuated and the emergency response plan started. Voltage drop and normal coolant temperature are ordinary operating conditions.
Question 20High-Voltage Safety, Personal Protective Equipment, and Service Procedures
A high-voltage battery removed from a collision vehicle with a cracked case should be:
- Returned to the customer for later use
- Charged to 100% before being stored
- Stored on a wooden shelf in the parts room
- Isolated outdoors away from combustibles Correct answer.
Explanation
A damaged pack may vent, ignite, or release electrolyte, so it is quarantined outdoors away from buildings and combustible material and monitored until it can be shipped for disposal. It is never returned to service or stored indoors on shelving. Charging a damaged pack increases the risk of thermal runaway.
Question 21High-Voltage Safety, Personal Protective Equipment, and Service Procedures
The arc flash boundary is defined as the distance at which:
- The temperature reaches 200 °C
- Incident energy equals 1.2 cal/cm² Correct answer.
- Incident energy equals 8 cal/cm²
- The sound level reaches 85 dB
Explanation
The arc flash boundary marks the distance at which incident energy falls to 1.2 cal/cm², roughly the onset of a second-degree burn. Inside that boundary, arc-rated PPE is required. Higher energy levels such as 8 cal/cm² occur closer to the arc and drive PPE category selection.
Question 22High-Voltage Safety, Personal Protective Equipment, and Service Procedures
For a lithium-ion high-voltage battery fire, the preferred suppression approach is to:
- Cover the pack with a salvage blanket and leave it
- Apply large amounts of water to cool the cells Correct answer.
- Use a Class D extinguisher as the first choice
- Use a CO2 extinguisher and close the hood
Explanation
Lithium-ion cells generate their own oxygen and heat, so suppression focuses on cooling with large volumes of water to stop propagation to adjacent cells. Class D agents are intended for combustible metals such as magnesium and sodium. CO2 and smothering blankets do not remove the heat and allow re-ignition.
Question 23High-Voltage Safety, Personal Protective Equipment, and Service Procedures
A high-voltage cable insulation test reads 0.4 MΩ at 500 V. What does this indicate?
- Normal resistance for a healthy cable
- Insulation breakdown requiring cable replacement Correct answer.
- A meter calibration error
- A fully charged high-voltage system
Explanation
Healthy high-voltage insulation typically measures in the tens of megohms or higher, so a reading of 0.4 MΩ indicates the insulation has broken down or become contaminated. The cable must be repaired or replaced before the vehicle is returned to service. Test voltage and meter condition should also be confirmed to rule out test error.
Question 24High-Voltage Safety, Personal Protective Equipment, and Service Procedures
An isolation fault monitor in a high-voltage vehicle detects:
- Excessive current draw by the inverter
- A loose 12-volt ground strap connection
- A failing cell balance circuit in the pack
- Loss of isolation to the chassis Correct answer.
Explanation
The isolation monitor measures resistance between the high-voltage conductors and the chassis and sets a fault when that resistance drops below a threshold. A loss of isolation means a person could become a current path to ground. It does not monitor 12-volt grounds or cell balancing.
Question 25High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Why must a high-voltage inverter be treated as energized even after the service disconnect is removed?
- The contactors are welded closed from the factory
- The battery cells keep producing voltage until fully drained
- DC bus capacitors hold a lethal charge Correct answer.
- The 12-volt battery back-feeds the high-voltage bus
Explanation
The inverter's DC bus capacitors store energy that can remain at a dangerous level after the battery contactors open, which is why the specified wait and voltage verification are mandatory. The 12-volt system cannot energize the traction bus on its own. Verification with a meter, not assumption, determines when the circuit is safe.
Question 26High-Voltage Safety, Personal Protective Equipment, and Service Procedures
What is the primary purpose of wearing leather protectors over rubber insulating gloves?
- Protect the rubber from cuts and abrasion Correct answer.
- Increase the dielectric strength of the glove
- Extend the electrical retest interval
- Keep the rubber glove clean between shifts
Explanation
Leather protectors are worn as the outer layer to shield the rubber insulating glove from mechanical damage such as cuts, punctures, and abrasion that would destroy its dielectric integrity. The rubber glove alone provides the electrical insulation; the protector adds no dielectric value.
Question 27High-Voltage Safety, Personal Protective Equipment, and Service Procedures
In most high-voltage vehicles, the cables that carry high voltage are identified by which color?
- Black
- Blue
- Red
- Orange Correct answer.
Explanation
High-voltage cable in automotive applications is conventionally color-coded orange to warn technicians that the conductor may carry dangerous voltage. This identification allows the technician to recognize and avoid or isolate high-voltage circuits before beginning work.
Question 28High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Which item must be removed before beginning work on an energized high-voltage system?
- Prescription eyeglasses
- Safety footwear
- Cotton work shirt
- Metal watch and rings Correct answer.
Explanation
Metal jewelry and watches are conductive and can bridge terminals or create a path for current through the body, causing severe burns or shock. All conductive personal items should be removed before any high-voltage task.
Question 29High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Insulated hand tools intended for high-voltage work should carry which marking?
- The tool's country of origin
- The date of the last electrical test
- A voltage rating and double-triangle mark Correct answer.
- The torque value for the fastener
Explanation
Insulated tools are marked with a voltage rating and the double-triangle symbol to show they have been tested to an insulation standard and are suitable up to that voltage. Tools without this marking must not be relied on for protection from shock.
Question 30High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Two technicians are servicing a high-voltage vehicle under a group lockout. What is the correct lock application practice?
- Locks are optional if a warning tag is attached to the disconnect
- Each technician applies a personal lock to the group lockout device Correct answer.
- Only the technician who removed the service disconnect applies a lock
- The supervisor holds all locks and releases them at shift end
Explanation
Every worker exposed to the hazard must apply a personal lock so that the system cannot be re-energized while anyone is still in contact with it. Group lockout hardware allows multiple locks and each is removed only by the person who applied it.
Question 31High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Which hard hat class is required when working on or near an energized high-voltage system?
- Any class, provided a bump cap is worn underneath
- Class E, because it is tested to withstand high voltage Correct answer.
- Class C, because it allows the most ventilation
- Class G, because it is rated for general electrical work
Explanation
Class E hard hats are tested to withstand high voltages and are the required head protection for high-voltage work. Class G hats have a much lower electrical rating and Class C hats offer no electrical protection at all.
Question 32High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Before separating a high-voltage connector, the technician should:
- Spray the terminals with contact cleaner while connected
- Grip the connector by the cable and pull firmly
- Wear cotton gloves to improve grip on the housing
- Confirm de-energization and that the interlock has opened Correct answer.
Explanation
A high-voltage connector must never be separated while current is flowing, because an arc can cause severe burns and connector damage. The circuit must be de-energized and any connector interlock or high-voltage interlock loop confirmed open before the housing is released.
Question 33High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Why is a second trained person required to be present during energized high-voltage work?
- To document the repair order in real time
- To hold the meter probes in place
- To operate a scan tool during measurements
- To de-energize the system and call for help Correct answer.
Explanation
The second person acts as a safety attendant who can isolate the system and summon emergency help if the worker is incapacitated. That role cannot be filled by someone whose attention is on tooling or paperwork.
Question 34High-Voltage Safety, Personal Protective Equipment, and Service Procedures
A technician's bare skin contacts liquid electrolyte from a lithium-ion pack. What is the appropriate first aid?
- Neutralize the electrolyte with baking soda paste
- Continue working and wash at the end of the shift
- Wipe the area dry and apply a bandage
- Flush with water for 15 minutes and seek medical care Correct answer.
Explanation
Lithium-ion electrolyte can contain fluoride compounds that cause chemical burns and deeper tissue damage, so the area must be flushed with copious water immediately and medical evaluation obtained. Prompt and prolonged irrigation is the accepted first aid.
Question 35High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Before reinstalling the high-voltage service disconnect, the technician should confirm that:
- The pack has been checked with a non-contact detector
- The 12-volt battery is disconnected
- The battery pack has been reset by cycling the ignition
- The area is clear, tools are removed, and no one is in contact Correct answer.
Explanation
Re-energization is a controlled step: the technician must verify that everyone is clear of the high-voltage components, no tools or debris remain in the pack or connectors, and the system is ready to be powered. Only then is the disconnect reinstalled.
Question 36High-Voltage Safety, Personal Protective Equipment, and Service Procedures
What is the correct method for lifting a high-voltage battery pack out of a vehicle?
- Support the pack on a floor jack with a wooden block
- A rated lift table attached at the designated lift points Correct answer.
- Lift by the cooling hose fittings with a sling
- Attach a chain hoist to the high-voltage cables
Explanation
Battery packs are heavy and must be supported using rated lifting equipment attached only at the manufacturer's designated lift points. Improvised support risks dropping the pack, damaging the case, or injuring the technician.
Question 37High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Why should a smart key be kept well away from the vehicle during high-voltage service?
- It can erase learned values in the battery controller
- Its proximity can re-energize the high-voltage system Correct answer.
- Its signal interferes with insulation test readings
- It may trigger the alarm during module testing
Explanation
With keyless systems, a smart key within range can allow the vehicle to wake and close contactors, re-energizing the high-voltage bus even though the technician believes it is isolated. The key should be stored out of range or in a shielded pouch for the duration of the work.
Question 38High-Voltage Safety, Personal Protective Equipment, and Service Procedures
After the service disconnect is removed and the specified wait time observed, the inverter terminals read 0 V. Ten minutes later the same terminals read 38 V. What does this indicate?
- The wait time was too long and the pack has self-recharged
- The 12-volt system is bleeding voltage into the high-voltage bus
- The meter is out of calibration and the reading should be ignored
- Inverter capacitors are recharging, so the circuit is still live Correct answer.
Explanation
Capacitors in the inverter can recover voltage after being discharged, a behavior often called dielectric absorption or capacitor recharge. A reappearing voltage means the circuit must continue to be treated as energized, and the technician must re-discharge and re-verify before touching conductors.
Question 39High-Voltage Safety, Personal Protective Equipment, and Service Procedures
Why is a high-voltage cable disconnected from the inverter and battery pack before an insulation resistance test?
- To keep the megohmmeter from tripping the service disconnect
- To allow the test to be performed with the cable still energized
- To increase the test voltage that can be applied safely
- To prevent component damage and false readings from parallel paths Correct answer.
Explanation
An insulation tester applies a high DC voltage that can destroy sensitive electronics, and any components left connected create parallel paths that make the measured value meaningless. Isolating the cable gives a valid reading of that cable's insulation only.
Question 40High-Voltage Safety, Personal Protective Equipment, and Service Procedures
A technician finds a coworker unresponsive on the floor beside an energized high-voltage pack. What should be done first?
- Wait for the supervisor to arrive before acting
- Pull the coworker clear by the arms
- De-energize and isolate the system before making contact Correct answer.
- Begin chest compressions immediately where the coworker lies
Explanation
Touching a victim who may still be in contact with an energized source can make the rescuer a second casualty. The system must be de-energized and isolated first, after which emergency services are called and rescue using non-conductive equipment can proceed if isolation is not immediately possible.
Question 41High-Voltage Battery Systems: Diagnosis, Service, and Repair
When servicing a high-voltage traction system that operates at 400 volts, the minimum class of insulating glove that provides adequate protection is
- Class 2, proof-tested at 17000 volts AC
- Class 00, proof-tested at 500 volts AC
- Class 0, proof-tested at 1000 volts AC Correct answer.
- Class 1, proof-tested at 7500 volts AC
Explanation
Insulating gloves are classified by their proof-test voltage, and Class 0 is rated at 1000 volts AC, which covers a 400-volt system with margin. Class 00 is rated at only 500 volts AC, leaving essentially no margin above a fully charged pack. Gloves must also be visually inspected and air-tested before each use and retested on the required interval.
Question 42High-Voltage Battery Systems: Diagnosis, Service, and Repair
In hybrid and electric vehicles, high-voltage cabling is identified by which insulation color?
- Green
- Blue
- Orange Correct answer.
- Red
Explanation
Industry convention and SAE J1673 specify orange for high-voltage conductors so technicians recognize cables that must never be cut, probed, or rerouted. The color serves as a visual warning in addition to the high-voltage labels found near components.
Question 43High-Voltage Battery Systems: Diagnosis, Service, and Repair
Before removing a high-voltage service disconnect plug, a technician should first
- Set the parking brake and chock the drive wheels
- Remove the high-voltage fuse from the junction block
- Confirm the pack state of charge is below 50 percent
- Turn the ignition off and disconnect the 12-volt auxiliary battery Correct answer.
Explanation
De-energizing the 12-volt system first prevents the battery management system from commanding the contactors closed and removes power from the control circuitry. Only after that should the high-voltage service disconnect be removed and the specified wait time observed.
Question 44High-Voltage Battery Systems: Diagnosis, Service, and Repair
After the high-voltage service disconnect is removed, the manufacturer's specified waiting period is required primarily to
- Allow the high-voltage capacitors to discharge Correct answer.
- Let the contactor coils demagnetize completely
- Allow the battery management system to erase stored codes
- Let the battery cells cool to room temperature
Explanation
Inverters and chargers contain capacitors that remain charged after the contactors open. The waiting period allows the internal discharge circuits to bring those capacitors down to a safe voltage before work begins.
Question 45High-Voltage Battery Systems: Diagnosis, Service, and Repair
The minimum meter safety category rating recommended for voltage measurements on a 400-volt traction bus is
- CAT IV 50 V
- CAT III 1000 V Correct answer.
- CAT II 600 V
- CAT II 300 V
Explanation
CAT III 1000 V meters are rated for measurements on fixed distribution circuits such as a traction bus, including transient overvoltage. CAT II ratings apply to portable equipment plugged into outlets and are not adequate for high-energy vehicle systems.
Question 46High-Voltage Battery Systems: Diagnosis, Service, and Repair
The high-voltage interlock loop (HVIL) on an electric vehicle is designed to
- Detect an opened high-voltage connector or cover and open the contactors Correct answer.
- Balance state of charge between battery modules
- Limit inrush current when the contactors close
- Measure insulation resistance between the pack and the chassis
Explanation
HVIL is a low-voltage loop routed through high-voltage connectors and service covers. If a connector is unseated or a cover removed, the loop opens and the battery management system opens the contactors to remove high voltage from exposed areas.
Question 47High-Voltage Battery Systems: Diagnosis, Service, and Repair
A nickel-metal hydride module used in an older hybrid pack contains cells with a nominal voltage of approximately
- 1.2 volts per cell Correct answer.
- 12.6 volts per cell
- 6.0 volts per cell
- 0.9 volt per cell
Explanation
Nickel-metal hydride cells have a nominal voltage of about 1.2 volts, so a typical six-cell module is rated around 7.2 volts. This is why NiMH hybrid packs use many series modules to reach several hundred volts.
Question 48High-Voltage Battery Systems: Diagnosis, Service, and Repair
Which document should be consulted for first-aid, spill, and handling instructions for a specific traction battery?
- The OBD-II readiness monitor list
- The battery manufacturer's safety data sheet Correct answer.
- The tire placard on the driver's door jamb
- The vehicle owner's manual maintenance schedule
Explanation
The battery manufacturer's safety data sheet and OEM service information give the chemistry-specific first-aid, PPE, and cleanup procedures for electrolyte exposure. General vehicle documents do not contain those details.
Question 49High-Voltage Battery Systems: Diagnosis, Service, and Repair
The precharge resistor in a high-voltage battery circuit functions to
- Boost pack voltage during motor starting
- Limit current while the inverter DC-link capacitors charge Correct answer.
- Discharge the pack to a safe storage voltage
- Equalize module voltages during charging
Explanation
Before the main positive contactor closes, a precharge contactor routes current through a resistor to slowly charge the inverter's DC-link capacitors. This limits inrush current and prevents arcing and pitting of the main contactor contacts.
Question 50High-Voltage Battery Systems: Diagnosis, Service, and Repair
A megohmmeter is used to check insulation resistance between a 400-volt traction pack and chassis. Which reading indicates the pack passes a typical insulation test?
- 100 ohms
- 10 megohms Correct answer.
- 0.05 megohm
- 0.5 megohm
Explanation
Insulation requirements are commonly expressed as a minimum resistance per volt of system voltage, which for a 400-volt pack works out to tens of kilohms at the very minimum. A reading of 10 megohms is far above that threshold and indicates good isolation.