TASC Physical Sciences Level 3 · Put your knowledge to work in context.

All case studies

The Failing Solar Charger on the Trail

A hiker carries a 20 W folding solar panel rated at 18 V open-circuit and 1.1 A short-circuit current in full sun. On a clear day at noon the panel charges a 10,000 mAh (37 Wh) power bank through a small controller. The hiker measures the panel output with a clamp meter: 0.62 A at 15.5 V while the bank charges. After three hours of direct sun the bank has gained only about 40 percent of its capacity. The panel is draped flat over a dark backpack, and the bank's input LED flickers whenever the hiker's shadow crosses the panel. The hiker suspects the panel is defective.

1. Calculate the power actually delivered to the bank at the measured operating point, and compare it with the panel's rated power. What does the gap tell you about whether the panel is defective?

Read the worked answer

Measured power = V × I = 15.5 V × 0.62 A ≈ 9.6 W, roughly half the 20 W rating. But the 20 W rating is under standard test conditions (1000 W/m², 25 °C cell temperature, perpendicular incidence). Flat-mounted on a dark pack, the panel is neither perpendicular to the sun nor cooled, so a 50 percent shortfall is expected rather than evidence of a fault. The open-circuit voltage of 18 V and the measured 15.5 V are consistent with a working panel under load. A defective panel would typically show near-zero current or a collapsed voltage, not a stable mid-range operating point. The evidence points to installation and orientation, not a broken panel.

2. The hiker got only about 40 percent of 37 Wh in three hours. Does that match the measured power? Show the arithmetic and identify the largest likely loss.

Read the worked answer

At 9.6 W for 3 h, energy delivered ≈ 28.8 Wh, which is about 78 percent of 37 Wh, not 40 percent. So something else is losing energy. The largest likely loss is charging efficiency: a small controller plus the bank's internal charging circuit typically converts only 60–75 percent of input energy into stored energy, and the flickering LED shows the panel is repeatedly dropping below the controller's startup threshold when shadowed. 28.8 Wh × 0.65 ≈ 18.7 Wh, about 50 percent of capacity - close to the observed 40 percent once partial shading and non-perpendicular sun are included. The arithmetic is consistent with a working panel plus realistic conversion losses.

3. The hiker wants to double the daily charge. Propose two changes and explain, using the data, which is likely to help more.

Read the worked answer

Change 1: tilt and aim the panel perpendicular to the sun and keep it off the dark pack. This raises irradiance toward the 1000 W/m² test value and reduces heating, which can recover much of the missing 10 W. Change 2: eliminate shading by moving the panel away from the hiker's body and pack straps, since each shadow event drops the panel below the controller threshold and restarts charging. Tilting and cooling likely helps more because the measured 9.6 W versus 20 W gap is dominated by incidence angle and temperature, whereas shading is intermittent. A third option, a larger panel, costs weight and does not fix the orientation loss, so it is the least efficient per gram carried.