Leak Test at the Yard

BC Air Brake Knowledge Test · Put your knowledge to work in context.

All case studies

Leak Test at the Yard

A driver is preparing a 2019 tandem-axle tractor with a tri-axle semi-trailer for a morning run. The system is fully charged to 120 psi, the engine is off, and the wheels are chocked. During the unapplied leak test, the gauge falls from 120 to 117 psi in one minute. During the applied leak test, with the foot valve fully depressed, it falls from 118 to 113 psi in one minute. The driver hears a faint hiss near the right rear tractor brake chamber, and a soap solution shows bubbles at the chamber clamp ring. The outside temperature is 5°C, and dispatch is scheduled in 20 minutes.

1. Interpret both leak-test results against typical BC limits. Is the vehicle roadworthy? Justify your decision.

Read the worked answer

Typical BC pass/fail limits are no more than 2 psi loss per minute with the brakes released and no more than 3 psi per minute with the brakes fully applied. This unit lost 3 psi unapplied and 5 psi applied, so both tests exceed the limits. The bubbles at the chamber clamp ring are direct evidence of a leak, not gauge error. A service-chamber leak can worsen quickly and may cause a brake to drag, fail to apply, or release a spring brake unexpectedly. Because the unapplied loss also exceeds the limit, I would not assume the chamber is the only fault; there may be a second leak in a supply line, valve, check valve, or drain. The vehicle is not roadworthy, and the 20-minute dispatch pressure does not change that.

2. What are the risks of the bubbles at the clamp ring, and what must be done before this unit leaves the yard?

Read the worked answer

Bubbles at the clamp ring mean air is escaping from the chamber, most likely past the diaphragm or the chamber seal. If the diaphragm ruptures, that wheel can lose service braking; on a spring-brake chamber, a sudden failure can also cause dragging or uncontrolled spring application. Tightening the clamp ring is not a proper repair. The chamber should be removed from service and repaired or replaced by a qualified technician, then both leak tests repeated. Before dispatch, the driver should also soap-test all fittings, hoses, valves, drain cocks, and tank welds to find the source of the unapplied leak; check pushrod stroke and slack adjuster condition; confirm compressor build-up and governor cut-in/cut-out; and complete a full pre-trip inspection. Only after the system holds pressure within limits and all brakes apply and release correctly should the unit move.

3. A co-driver argues that 3 psi in the unapplied test is only 1 psi over and is close enough. How should the driver respond?

Read the worked answer

Leak limits are maximum allowable values, not targets. One psi over the limit still means the system cannot be certified, and the leak will not fix itself; vibration, temperature change, and seal wear usually make it worse. In cold weather, seals contract and moisture can freeze, so a marginal leak can become a major loss quickly. The audible hiss and soap bubbles independently fail the inspection even if the gauge loss were within the limit. The correct response is to record the results, keep the unit out of service, and have the leak repaired and retested. A dispatcher's schedule does not override the inspection standard.