BC Air Brake Knowledge Test study materials
BC Air Brake Knowledge Test study resources

Compressor Build-Up and Wet Tank

BC Air Brake Knowledge Test · Put your knowledge to work in context.

All case studies

Compressor Build-Up and Wet Tank

At a cold-morning start, a tractor-trailer at fast idle builds from 85 to 100 psi in 80 seconds. The governor cuts out at 105 psi and cuts in at 85 psi. While the engine idles, the air dryer purges about every 40 seconds. The wet-tank drain yields roughly 150 mL of milky water with several oil droplets. The compressor discharge line is hot to the touch, and there is no audible leak. Ambient temperature is -5°C, and the driver wants to leave immediately to avoid a delay. The truck is otherwise loaded and ready.

1. Identify the abnormalities in the build-up, governor, and drain results. What do they suggest about the compressor, governor, and air dryer?

Read the worked answer

Three things are abnormal: build-up is too slow, the governor window is too low and narrow, and the dryer is cycling too often. A typical build-up from 85 to 100 psi should take about 45 seconds at fast idle, not 80. Cut-out should be roughly 120-135 psi, with cut-in around 100 psi; 105/85 means the compressor restarts too soon and has little reserve. Purging every 40 seconds at idle suggests the compressor is running almost continuously, either because of a leak, a restricted dryer, or a governor problem. The milky water shows the dryer is not removing moisture, and oil droplets suggest compressor oil carryover. Together these point to a worn compressor and/or failed dryer, with a possible governor or leak contribution. Cold weather makes the moisture especially dangerous.

2. How would you isolate a compressor problem from a system leak or a governor fault?

Read the worked answer

First, with the system fully charged and the engine off, perform the unapplied and applied leak tests; a system leak will show as a continuous pressure drop and can be located with soap solution. Second, check the governor: cut-in and cut-out should match the manufacturer's specification, and the unloader should stop the compressor from pumping at cut-out. Third, if the system holds pressure and the governor is correct, measure build-up time again from 85 to 100 psi at fast idle. A slow build with no leaks points to the compressor, a restricted discharge line, a slipping belt, or a blocked air dryer. Inspect the dryer purge valve and desiccant; a dryer that purges constantly can waste air and mimic a compressor fault. Drain the wet tank and check for oil, which supports compressor wear.

3. What should the driver do before departure, and why is simply draining the tanks not enough?

Read the worked answer

Draining the tanks removes liquid water but does not restore the dryer, repair the compressor, or correct the low governor setting. The unit should be kept out of service until the air dryer is serviced or replaced, the compressor is checked for wear and oil passage, the governor is tested and adjusted or replaced, and the system passes leak and build-up tests. The driver should also drain all reservoirs, check for oil and coolant, inspect the compressor belt and discharge line, and confirm the low-pressure warning and spring brakes operate. Simply draining the tanks leaves moisture in the lines and valves; at -5°C it can freeze and cause brake drag or a complete loss of air. The low cut-out also leaves too little reserve for repeated brake applications.