AMIE Section A Examination · Put your knowledge to work in context.

All case studies

Choosing a Test Method for a Small-Sample Material Check

A student project team must confirm that a batch of 12 machined aluminium pins meets a specified minimum hardness. The batch was supplied with a mill certificate stating a hardness of 95 HV, but the team suspects the certificate refers to a different heat treatment. The available equipment is a bench Rockwell tester (B scale), a portable Leeb rebound hardness tester, and a laboratory Vickers tester that requires a polished specimen and a 30-minute turnaround per pin. The team has one afternoon, a budget for 4 Vickers tests, and needs a defensible conclusion for a report. The pins are 6 mm diameter and 40 mm long. The specification is written in Vickers hardness.

1. Evaluate the three test methods for this task and recommend a testing strategy.

Read the worked answer

Each method has a different role.

  • Vickers is the specified method, so it is the only one that directly demonstrates compliance. Its drawback is cost and time: 4 tests in an afternoon is feasible, but 4 pins out of 12 is a sample, not a full check.
  • Rockwell B is fast and the pins are large enough to support it, but it measures a different scale. Conversion to HV is approximate and depends on material and condition, so a converted value is indicative, not a compliance result.
  • Leeb rebound is portable and fast but has significant scatter on small, light parts; a 6 mm x 40 mm pin may need support or coupling to get reliable readings, and it is also an indirect method.

Recommended strategy: use Leeb or Rockwell B as a rapid screening pass over all 12 pins to detect any gross outliers or a systematically soft batch, then run the 4 budgeted Vickers tests on a purposive sample - the pins that screened lowest plus one or two typical pins. Report Vickers results as the compliance evidence and screening results as supporting information only.

2. The team finds the Vickers results are 88, 90, 91 and 89 HV against a minimum of 95 HV. The Rockwell screening broadly agrees. What conclusion is defensible, and what cautions apply?

Read the worked answer

The defensible conclusion is that the sampled pins do not meet the 95 HV minimum and that the mill certificate is not supported by the team's measurements. All four Vickers results fall 4 to 7 HV below the minimum, and the independent screening method points the same way, which reduces the chance of a single-method error.

Cautions to state in the report:

  • The Vickers sample is 4 of 12 pins, chosen partly because they screened low. That is appropriate for detecting non-compliance but does not estimate the batch average without bias. The report should say 'the tested pins fail' rather than 'the batch average is 89 HV'.
  • Hardness varies with position and surface preparation. The report should record where each indent was made and confirm the specimens were polished to the required finish.
  • Vickers results are load-dependent at low loads; the test load should be stated.
  • The certificate may refer to a different heat treatment lot, which is the team's original suspicion and is now supported, but confirming that requires traceability documents, not more hardness tests.

The correct action is to report non-compliance on the tested pins, recommend the batch be quarantined, and ask the supplier to reconcile the certificate with the delivered material.

3. A teammate suggests reporting only the Rockwell results because they cover all 12 pins and 'look more complete'. Assess this suggestion.

Read the worked answer

The suggestion should be rejected. Coverage is not the same as validity. The specification is written in Vickers, and Rockwell B values cannot be converted to Vickers with enough accuracy to certify compliance. Presenting Rockwell results as the primary evidence would overstate what was measured and could mislead the reader into thinking the specified test was performed.

The 'more complete' appearance is also misleading in a second way: a full-coverage indirect test does not compensate for a small direct sample. The honest report presents both, clearly labelled: Rockwell screening across 12 pins as supporting evidence, and 4 Vickers results as the compliance evidence, with the sampling rationale explained.

If the team wants stronger compliance evidence, the correct move is to request budget for more Vickers tests, not to substitute a different scale. The report should state the limitation explicitly so the reader can judge the conclusion on accurate information.