You are the FSR supervising a crew of three electricians on a multi-story residential project. One afternoon, an apprentice receives a shock while working on a live 347V lighting circuit. The apprentice was not wearing PPE and was not directly supervised at the time; you were on another floor. The apprentice is shaken but not seriously injured. The site superintendent tells you to 'keep it quiet' to avoid delays. The project manager asks you to not report it to WorkSafeBC or Technical Safety BC because it was minor. You know that the apprentice had been told to lock out the circuit but failed to do so. The circuit was supposed to be de-energized. The apprentice is a second-year and not yet qualified to work on 347V. The incident occurred at 2:30 PM; it is now 3:00 PM. The project has a safety meeting scheduled for tomorrow.

1. What are your immediate obligations regarding incident reporting and worker safety?

Read the worked answer

As the FSR, you must immediately ensure the apprentice receives medical attention, even if they appear fine. You must secure the scene and ensure the circuit is de-energized and locked out. You must report the incident to WorkSafeBC immediately (within 24 hours for serious incidents, but any shock requiring medical treatment is reportable) and to Technical Safety BC as a dangerous occurrence. You must also notify the contractor's safety officer and the joint health and safety committee. The superintendent's instruction to keep it quiet is illegal; you cannot comply. You must document the incident thoroughly, including witness statements, conditions, and corrective actions. You should also notify the apprentice's union or training authority if applicable. Failure to report can result in fines and loss of your FSR certification.

2. What supervision failures contributed to the incident, and what corrective actions must you implement?

Read the worked answer

The supervision failures include: allowing an apprentice to work on a live 347V circuit without direct supervision, not ensuring lockout/tagout was followed, and not enforcing PPE use. As FSR, you are responsible for ensuring that only qualified persons work on high-voltage circuits and that apprentices are supervised according to their level. Corrective actions: 1) Implement a mandatory lockout/tagout procedure with personal locks; 2) Require a job hazard analysis (JHA) for all live work; 3) Provide additional training on electrical safety and PPE; 4) Increase supervision presence, especially on higher-risk tasks; 5) Review the apprentice's scope of work with the training sponsor; 6) Conduct a stand-down safety meeting to discuss the incident and lessons learned. You must also document these actions and follow up to ensure compliance. The FSR must sign off on the revised safe work procedures.