CCIE Data Center · Put your knowledge to work in context.

All case studies

A misleading mirrored capture and partial service path

A troubleshooting capture is collected through a mirror session that includes both ingress and egress observations for the relevant interfaces. The analyst counts repeated frames and concludes immediately that the fabric is looping. The application's forward connection attempt passes an ACL, but the return route traverses a different stateful service whose policy has not been checked. Device clocks also disagree, making cross-device timestamps difficult to compare. Management access remains healthy, and a long averaging window shows low utilization. The service owner needs an evidence-based explanation before authorizing any broader security rule or topology change. The engineer must distinguish observation artifacts from actual duplicate forwarding and inspect the complete bidirectional application path.

1. How should the capture and timeline be interpreted?

Read the worked answer

Identify mirror sources and directions so multiple observations of one packet are not automatically called a loop. Establish coherent clock and timestamp interpretation, and correlate relevant counters and events at the actual observation points rather than infer causality from unaligned logs.

2. What application-path checks remain?

Read the worked answer

Trace both directions through routing, ACLs, and the stateful service. A permitted forward attempt does not prove session completion. Inspect actual denial or state evidence before broadening policy, and validate the intended service after the approved targeted correction.