Data Center Server and Storage Architecture
This domain tests how Cisco UCS components are cabled and addressed, how RAID and disk media behave, and how SAN and service-profile abstractions connect servers to storage. Expect capacity arithmetic, identity questions, and protocol matching.
UCS hardware model
- A B-series chassis holds 8 half-width blades (or 4 full-width), two IOMs, four PSUs, and fan modules; the IOMs uplink to Fabric Interconnects.
- C-series rack servers use a standalone CIMC or are integrated into UCS Manager.
- VICs present vNICs and vHBAs; mezzanine adapters do the same for blades.
- Service profiles and pools (MAC, WWNN/WWPN, UUID, boot, BIOS, firmware) make servers stateless. A replacement blade inherits the profile and its identity.
RAID and media
- RAID 0 stripes with no protection; RAID 1 mirrors; RAID 5 stripes with one parity disk (one failure); RAID 6 dual parity (two failures); RAID 10 mirrors stripes for write performance.
- Write penalty: RAID 1/10 = 2, RAID 5 = 4, RAID 6 = 6 I/Os per host write.
- SAS is dual-port and enterprise-grade; SATA is single-port and cheaper; NVMe over PCIe has the lowest latency; SSDs shift the discussion to endurance and wear.
- A hot spare is idle capacity that rebuilds automatically and is not counted as usable.
Storage protocols and SAN
- Fibre Channel uses WWPNs and zoning on MDS switches; VSANs separate fabrics logically.
- FCoE carries FC frames over lossless 10G Ethernet with DCB/PFC; NPV/NPIV let the Fabric Interconnect act as an access switch to an upstream SAN.
- iSCSI and NFS run over IP; LUN masking controls which initiator sees a LUN.
Worked example
A RAID group has six 900 GB drives and one global hot spare. The other five drives are RAID 5. Usable capacity = (5 - 1) x 900 GB = 3,600 GB. If those five data drives were RAID 10, usable would be 2 x 900 GB = 1,800 GB, and RAID 10 needs an even drive count. The hot spare is excluded from both calculations. Reasoning: subtract parity first, multiply by drive size, never add the spare.
Traps
- Confusing WWNN (node) with WWPN (port).
- Assuming RAID protects against a lost array or site failure.
- Counting a hot spare as usable capacity.
- Forgetting the RAID 5 write penalty is 4, not 1.