Optical and Access Networks (FTTx, xDSL, PON)
This domain covers the physical last mile: fibre characteristics and WDM, PON architecture and power budgeting, and copper access evolution from ADSL to G.fast. Power-budget arithmetic and wavelength assignment are the most common calculation items.
Fibre and WDM
- Standard single-mode fibre (ITU-T G.652D) has zero-dispersion near 1310 nm and minimum loss near 1550 nm (about 0.2 dB/km, versus roughly 0.35 dB/km at 1310 nm). G.657 fibre is bend-insensitive for in-building drops.
- EDFA amplifies the C-band (about 1530–1565 nm). DWDM channels follow the ITU-T G.694.1 grid anchored at 193.1 THz with 100 or 50 GHz spacing. Reach is limited by OSNR, chromatic and polarisation-mode dispersion, and non-linear effects.
PON
- Architecture: OLT in the exchange - ODN with splitters and fibre - ONT at the premises. GPON runs 2.488 Gbit/s downstream and 1.244 Gbit/s upstream, with 1490 nm downstream, 1310 nm upstream and 1550 nm reserved for RF video overlay; typical reach 20 km and split 1:32 or 1:64.
- XG-PON is 10/2.5 Gbit/s, XGS-PON is symmetric 10/10, NG-PON2 uses TWDM wavelengths.
- Downstream is a shared broadcast encrypted per ONT; upstream uses TDMA granted by the OLT.
- Power budget classes: class B+ about 28 dB, class C+ about 32 dB.
xDSL and FTTx
- ADSL2+ reaches up to 24 Mbit/s downstream on short loops, using DMT across many subcarriers; VDSL2 profile 17a reaches roughly 100 Mbit/s; vectoring cancels far-end crosstalk; G.fast pushes higher rates over very short copper.
- FTTC (cabinet, VDSL/G.fast), FTTB (building, copper or LAN in-building), FTTH (fibre to the home).
Worked example
A 1:32 splitter has an ideal loss of 10 log₁₀(32) = 15.05 dB, but real parts add excess loss, often 16.5–17 dB. Take 17 dB, plus 10 km × 0.35 dB/km = 3.5 dB, plus two connectors at 0.5 dB = 1 dB and splices at 0.5 dB: total ≈ 22 dB. Against a class B+ budget of 28 dB this leaves about 6 dB for ageing, repairs and temperature - acceptable but not generous, so a longer reach or higher split would need class C+.
Traps that cost marks
- Confusing downstream (1490 nm) with upstream (1310 nm) wavelengths.
- Forgetting that splitter loss rises about 3 dB for every doubling of the split ratio.
- Quoting GPON downstream as 2.5 Gbit/s instead of 2.488 Gbit/s.
- Treating xDSL rate as fixed rather than loop-length and crosstalk dependent.