Designing the Refresh With Three Engineers and No Room for a Rework

CPDN · Put your knowledge to work in context.

All case studies

Designing the Refresh With Three Engineers and No Room for a Rework

A manufacturer is refreshing two data centres with USD 900,000 total capital. Each holds 240 VMs on a three-tier estate. North–south peaks at 4 Gbit/s, but east–west traffic from a new microservice application is growing 30% a year and now exceeds north–south at peak. Today the sites run Catalyst 6500-class cores with Spanning Tree, 1 GbE top-of-rack, and VLANs stretched between sites to support the standby tier. The infrastructure team is three engineers, none with production VXLAN, EVPN or BGP-EVPN experience; one writes basic Python. About 40% of workloads will move to a co-location facility in 24 months. Target life is five years. The CIO wants a design that survives two simultaneous rack failures and can be operated by the current team.

1. Spine-leaf or a refreshed collapsed core? Make a recommendation and state what evidence would flip it.

Read the worked answer

Recommend two-tier spine-leaf per site: 2 spines and 4 leaves, eBGP underlay, ECMP, every leaf dual-homed to both spines. Reason: east–west already exceeds north–south and is compounding at 30%; a collapsed core forces every east–west flow through one pair, and STP blocks half the links.

But spine-leaf alone does not satisfy the requirement. Two simultaneous rack failures is a compute placement problem, not a fabric problem. The design must spread each application's VMs across at least three racks with anti-affinity, and keep at least one spine and three leaves outside any two-rack failure domain. Write that into the design document or the CIO's requirement will not be met.

What would flip the decision: east–west growth flattening below 10% and staying there for two quarters; the co-location move being cancelled; or a capital ceiling near USD 400k, where a collapsed core with MC-LAG and 10 GbE ToR is defensible at 240 VMs. Also flip if the site cannot support the fibre count - spine-leaf triples the inter-rack cabling.

2. How would you handle workload mobility and segmentation - stretched VLANs, EVPN-VXLAN, or routed Layer 3? What has to be true before you deploy an overlay?

Read the worked answer

Default to routed Layer 3 to the leaf with no stretching. Most three-tier workloads do not need L2 adjacency; a standby tier with DNS/GSLB or a load balancer health check works fine across subnets. This removes the failure domain that today lets a broadcast storm in one site reach the other.

Use EVPN-VXLAN selectively, only for the workloads that need an any-rack subnet during a live migration, and cap the number of stretched subnets - every stretched subnet is a shared failure domain.

Prerequisites before overlay, in order:

  • Underlay built and documented by someone who can troubleshoot BGP - training budget of roughly USD 10–15k per engineer plus a lab, or budget for a managed service.
  • Automation for the underlay (IaC templates) so a 4-leaf change is not hand-typed at 02:00.
  • A support contract that covers EVPN, and a documented rollback to routed L3.

If those are not funded, do not deploy the overlay - a fabric nobody can operate fails at 03:00, not in the design review.

3. Name the top three design risks and say how each is mitigated or explicitly accepted.

Read the worked answer
  1. Skills gap (highest). Three engineers, no EVPN experience, five-year life. Mitigate: training and lab before cutover, one contractor or partner for the first 90 days, runbooks validated by a game day. Accept residual risk in writing with the CIO if training is cut.
  2. Cabling and optics cost overrun. Spine-leaf multiplies inter-rack links and 100 GbE optics; the USD 900k can vanish in optics and a five-year refresh. Mitigate: model optics as a recurring line item, not capex, and standardise on one optic family to keep spares cheap.
  3. Vendor lock and operational fragility. A single-vendor, single-skill stack with no fallback. Mitigate: keep configuration in version control and IaC so intent survives a platform change, contract for spares and 4-hour support, and avoid features with no standards equivalent.

Explicitly accept: no in-house 24/7 eyes - that is a monitoring and escalation design problem, addressed separately.