CT Asbestos Abatement · Put your knowledge to work in context.

All case studies

Negative Pressure Fails in a School Basement

A school abatement crew is removing 600 square feet of friable boiler insulation inside a 10,000-cubic-foot basement enclosure during summer break. Two HEPA air machines are rated 600 cfm each; one is running at 450 cfm because its prefilter is loaded, and the second tripped a breaker at 9 a.m. The enclosure manometer reads -0.004 inches of water column; the site plan requires -0.02 inches and at least four air changes per hour. A worker inside is wetting debris and using a HEPA vacuum; a second worker is cutting a pipe with a reciprocating saw outside the containment while the flap door is propped open for ventilation. The project monitor sees faint dust on the poly at the flap and the worker inside reports a headache. The supervisor wants to finish the last 50 square feet before lunch.

1. Calculate the current air changes per hour and evaluate the pressure reading. Should work continue?

Read the worked answer

With one machine operating at 450 cfm, the enclosure receives 450 times 60, or 27,000 cubic feet per hour. Dividing by 10,000 cubic feet gives 2.7 air changes per hour, below the required 4. Four air changes per hour would require 10,000 times 4 divided by 60, or about 667 cfm. If both machines ran at their rated 600 cfm, the total would be 1,200 cfm, or 7.2 air changes per hour, so capacity is adequate only when both operate correctly. The manometer at -0.004 inches of water column is far short of the required -0.02 inches, so the enclosure is not adequately negative to surrounding spaces. The propped flap further defeats containment. Work should stop immediately. The dust on the poly and the headache are additional reasons to evacuate, inspect, and correct the engineering controls before anyone reenters.

2. What immediate corrective actions should the supervisor take?

Read the worked answer

Stop removal, have the worker leave through the decontamination sequence, and close the flap. Do not dry-sweep or use a conventional vacuum. HEPA-vacuum and wet-wipe the flap area and any visible dust, then inspect the poly for tears and seal them. Restore power to the tripped machine on a circuit that will not be overloaded, replace the loaded prefilter, and verify that both units are producing adequate airflow. Recheck the manometer after the enclosure is closed and run the units until the pressure is at or below -0.02 inches and airflow is at least 4 air changes per hour. Investigate the headache: it may reflect heat, respirator use, or another exposure, so the worker should be evaluated and the space checked before reentry. Only then should the last 50 square feet be completed, with the flap kept closed and pipe cutting controlled.

3. What engineering and work-practice changes would prevent a recurrence?

Read the worked answer

The enclosure needs reliable independent power, labeled circuits, and a schedule for checking breaker capacity before the job starts. Air machines should have airflow alarms or daily airflow measurements, not just a rating plate, and prefilters should be changed on a set schedule or when airflow drops. A manometer with a visible alarm and a written log would make the pressure loss obvious. The flap should never be propped open; materials should pass through a properly designed airlock or be bagged inside. Pipe cutting should be done with wet methods or a glove bag and controlled ventilation, not dry sawing near an open flap. The supervisor should conduct pre-shift checks and stop work whenever pressure or airflow is out of specification. These changes address the specific failures: one machine down, a loaded filter, an open flap, and no early warning.