MPPSC SES Civil study materials
MPPSC SES Civil study resources

Expansive Black Cotton Soil at Dewas: Footing Capacity versus Heave

MPPSC SES Civil · Put your knowledge to work in context.

All case studies

Expansive Black Cotton Soil at Dewas: Footing Capacity versus Heave

A two-storey school building near Dewas is to be founded on black cotton soil. Each interior column carries 700 kN at service. The trial pit shows 1.2 m of loose fill, then stiff expansive clay to at least 6 m depth. Free swell index is 70 per cent, water table is 4.5 m and is not expected to rise above 4 m, and SPT N values in the clay are 6 to 9. Undrained shear strength from triaxial tests is 30 kPa and unit weight is 18 kN/m³. The proposed detail is an isolated footing 2.0 m × 2.0 m founded at 1.5 m depth, with a 300 mm sand cushion below it. The contractor cites a nearby eight-year-old building with the same detail that has not cracked, and argues that N above 5 means the ground is stiff and no problem exists. You must verify the footing, judge the sand-cushion argument and recommend a foundation.

1. Compute the net safe bearing capacity and check the proposed 2.0 m × 2.0 m footing.

Read the worked answer

For a square footing on saturated clay, treat the undrained case as φ = 0, Nc = 5.7, Nq = 1, Nγ = 0:

  • Gross ultimate qu = 1.3 c Nc = 1.3 × 30 × 5.7 = 222 kPa.
  • Net ultimate = 222 - γD = 222 - (18 × 1.5) = 195 kPa.
  • Net safe with FOS 2.5 = 195/2.5 = 78 kPa.

Applied pressure = 700/(2.0 × 2.0) = 175 kPa, which is 2.2 times the permissible value. The proposed footing is grossly inadequate on bearing capacity alone.

Required area = 700/78 = 9.0 m², i.e. a minimum 3.0 m × 3.0 m footing if a shallow foundation were retained (with FOS 3 the value drops to about 65 kPa and the size rises to 3.3 m). Note also that with N = 6 to 9 and c = 30 kPa, settlement will probably govern before bearing capacity, so a full consolidation settlement check, not just a capacity check, is mandatory before any shallow option is accepted. Because the clay is expansive, even a satisfactory bearing capacity would not control seasonal heave, which is the real design issue.

2. Evaluate the contractor's sand-cushion proposal and the argument based on the nearby building.

Read the worked answer

A 300 mm sand cushion is not a remedy, for four reasons.

  1. The expansive clay is not removed. Heave is generated in the clay itself, 2 to 4 m deep, from seasonal moisture change. A cushion above it changes neither the swell potential nor the swelling pressure under the footing.
  2. The cushion can worsen the problem. Sand is a permeable layer; it collects water from rain, garden taps and broken drains and feeds it directly to the clay under the footing, which can intensify local heave and produce differential movement between footings.
  3. Bearing capacity gain is negligible. The cushion only acts as an added layer of a stronger material; at 300 mm thickness and 2 m width, the load spreads too little to change the 78 kPa allowable value appreciably, and the 1.2 m of loose fill above the clay remains.
  4. The evidence is anecdotal. An eight-year-old building is a single sample, with different trees, drainage, fill and loading, and may simply not yet have passed through an unusual drought-wetting cycle; heave damage commonly appears 10 to 15 years later. N = 6 to 9 means a stiff consistency, not a non-expansive stratum.

The proposal must be rejected and the nearby building cannot be used as justification.

3. Recommend a foundation scheme and list the checks you would insist on before construction.

Read the worked answer

Adopt under-reamed piles (IS 2911 Part 3) with a 300 mm shaft, bulb diameter 2.5 times the shaft (about 750 mm), taken to about 3.5 m depth, with at least one bulb below the zone of seasonal moisture change and a rigid pile cap tied by plinth beams. Under-reamed piles are the standard solution here because the bulb anchors the pile against uplift from swelling and because the shaft bypasses the active zone; a raft on expansive clay would still heave unless a thick non-swelling cushion were placed, which is costlier at this load level.

Checks to insist on:

  • Capacity in the stiff clay using measured c (side friction ignored over the top 1.5 m and end bearing of the bulb from IS 2911); with c of 30-50 kPa and two bulbs, an economical group of 4 to 6 piles per 700 kN column is typical, but the number must come from the actual computation, not from this estimate.
  • Uplift capacity against swelling pressure, and structural design of the bulb and reinforcement for tension.
  • Consolidation settlement of the clay group and differential settlement between adjacent footings (limit about 20 mm differential and 40 mm total for framed buildings).
  • Reject the 1.2 m of loose fill as a founding medium; remove or treat it, provide a 1.5 m paved apron sloping away from the building, and keep trees at least 3 m away to limit moisture variation.