A testing firm is asked to test a 2,600-square-foot, three-level home: a finished basement with an occupied bedroom, a main floor, and an attached vented crawlspace that connects to the basement through a hatch. The family's water comes from a private well, and the previous owner's water test showed 6,500 pCi/L of radon in the water. The client, a smoker, wants "the cheapest test that will tell me if the house is safe," and asks whether one charcoal canister in the basement is enough. The firm owns charcoal canisters, alpha-track detectors, electret ion chambers, and two continuous monitors. The house has a whole-house humidifier and a radon system installed in 2004 with an unlabeled fan. The client's child sleeps in the basement bedroom five nights a week.

1. Design the test: how many devices, what type, where, and for how long?

Read the worked answer

One canister in the basement is not enough, on coverage and on device choice.

Coverage. The decision location is the lowest livable level - the finished basement - and the specific room that matters is the one where the child sleeps. Place one device in that bedroom. A single basement device does not characterize the main floor, so add one there. The crawlspace is a source and a pathway, not living space; inspect it and note the hatch, but it is not a test location unless it is occupiable.

Device. For a non-real-estate decision, a long-term alpha-track detector over 90 days to a year gives the best annual-average estimate, and this family's exposure is year-round. If they need an answer sooner, a continuous monitor for 48 hours under closed-house conditions, or an electret ion chamber, works. Charcoal is the cheapest and the least precise, with no time resolution - the wrong tool for a house that already has a system, a water issue, and a child sleeping downstairs.

Precondition. The 2004 system must be verified operating before any test: fan running, u-tube or manometer showing suction, and the fan label read. Testing a house with a dead system tests the house, not the system. Note the whole-house humidifier too.

2. What does 6,500 pCi/L of radon in the private well contribute to indoor air, and how does that change the plan?

Read the worked answer

The standard rule of thumb is that 10,000 pCi/L of radon in water contributes roughly 1 pCi/L to indoor air, so 6,500 pCi/L is on the order of 0.6 to 0.7 pCi/L. That is meaningful but usually not the main event compared with soil gas.

The contribution is not constant. It rises with heavy shower and bath use, with aeration at showerheads and dishwashers, and with how long water sits in the house. It is an average, not a floor.

What it changes:

  • It is not a reason to skip the air test. The air measurement is still the primary number and the one compared to the action level.
  • It is a reason to confirm the water result with a proper water test - the previous owner's number is not your data, and water sampling has its own protocol (sample handling, no aeration, lab certification).
  • Treatment should be discussed. Aeration is the effective method for radon in water; granular activated carbon works but has disposal and buildup considerations.
  • If the air result lands near 4 pCi/L, the water contribution can push total exposure over, so it belongs in the interpretation, not in a footnote.

A private well also means no municipal dilution and no utility oversight - the homeowner owns this problem.

3. The client is a smoker and wants to know whether the house is "safe." How do you answer?

Read the worked answer

Tell him the truth: no test tells you a house is safe, and radon is only one of the things he is asking about. What a test can do is say whether the house is above or below the action level and whether mitigation is warranted.

The smoking detail matters enormously. Radon and smoking interact multiplicatively rather than additively on lung cancer risk - a smoker exposed to elevated radon is at substantially higher risk than either factor alone would suggest. For him, the argument for testing properly and acting at a lower threshold is stronger, not weaker.

"Cheapest" is the wrong frame here. The cheapest test may be a charcoal canister that gives a single imprecise number with no time resolution, in a house with an existing system and a water issue. The right answer is: test the basement bedroom and the main floor, use long-term devices if he can wait, confirm the water, and verify the existing system.

Practical decision rule: at or above 4 pCi/L, mitigate. Between 2 and 4, EPA says consider mitigation - and for a smoker with a child sleeping in the basement, I would recommend it. Quitting is still the single largest risk reduction available to him.