Half-Mask Respirator Selected for an Exposure Above Its Assigned Protection Factor

KY Asbestos Abatement · Put your knowledge to work in context.

All case studies

Half-Mask Respirator Selected for an Exposure Above Its Assigned Protection Factor

A worker inside a negative-pressure enclosure is removing asbestos-containing pipe insulation with hand tools. A personal breathing-zone sample on the worker gives an 8-hour TWA of 1.1 f/cc, and a 15-minute peak sample gives 2.0 f/cc. The employer has assigned him a half-mask, negative-pressure HEPA respirator. He last passed a quantitative fit test 14 months ago, has a three-day beard, and his HEPA cartridges have been in service for four shifts. The written respiratory protection program is a one-page handout. The project supervisor says the half-mask is acceptable because the measured TWA is "only about ten times the limit" and the worker has never complained. The worker reports a headache and says the mask "leaks around the cheeks." The containment's negative pressure is holding at -0.02 in. w.c., and no engineering changes are planned.

1. Calculate the maximum use concentration for the assigned respirator and determine whether it is adequate. Show the reasoning.

Read the worked answer

The OSHA PEL is 0.1 f/cc as an 8-hour TWA, and the STEL is 1.0 f/cc over 30 minutes. A TWA of 1.1 f/cc is 11 times the PEL. A half-mask negative-pressure HEPA respirator has an assigned protection factor of 10, so its maximum use concentration is 10 × 0.1 = 1.0 f/cc. The measured 1.1 f/cc exceeds that ceiling, so the half-mask is not adequate even before considering the beard. The 15-minute peak of 2.0 f/cc also exceeds the STEL and is 20 times the PEL. A full-facepiece HEPA APR has an APF of 50 and a maximum use concentration of 5.0 f/cc, which would cover the measured TWA and peak for a clean-shaven worker. A loose-fitting PAPR with HEPA has an APF of 25 and a maximum use concentration of 2.5 f/cc; that could cover this exposure, but the margin is thin and the specific model must be listed for asbestos. Verify the respirator table in 29 CFR 1926.1101 before selecting.

2. What fit-testing, seal, and medical requirements apply, and what are the options given the worker's beard?

Read the worked answer

Tight-fitting respirators require an annual fit test; his last quantitative fit test was 14 months ago, so it is expired. A three-day beard breaks the sealing surface, so he cannot rely on a half-mask or any tight-fitting full-facepiece until he is clean-shaven at the time of fit testing and each use. A user seal check is required before each use, but it does not replace a fit test. Options are: require him to shave and pass a fit test before reentry, or move him to a loose-fitting PAPR with HEPA if that model's APF and asbestos approval cover the exposure. He also needs a medical evaluation before fit testing or respirator use, and training on donning, seal checks, cartridge change, and limitations. The headache and leak complaint should trigger removal from the area and evaluation; do not tell him to tighten the mask and continue.

3. What engineering and program changes should be made before the worker reenters the containment?

Read the worked answer

The exposure and STEL exceedance show that engineering controls are inadequate. Improve local exhaust and negative air, use glove bags or wet methods, reduce worker time near the disturbance, and re-monitor personal breathing-zone exposures. A respirator can supplement controls but should not be used to justify a continuing STEL exceedance without reassessment. Replace the one-page handout with a written respiratory protection program covering selection, medical evaluation, fit testing, training, cartridge change schedules, storage, and program evaluation. Verify HEPA cartridge service life and document replacement. Recheck the containment's negative pressure and airflow patterns after changes. The worker should not reenter until the exposure is controlled, the fit test and medical clearance are current, and the selected respirator's maximum use concentration exceeds the measured exposure.