220 Workers, One Crane Horn, and 37 People Missing

NCCER CSSS · Put your knowledge to work in context.

All case studies

220 Workers, One Crane Horn, and 37 People Missing

You are site safety manager on a 220-worker, 14-story cast-in-place project on nine acres. The emergency action plan is 14 months old. The muster point is the gravel area beside the site trailer, 60 feet from the tower and inside the slewing radius of the tower crane. The evacuation alarm is the crane horn, tested monthly. Subcontractor crews sign in at their own trailers; your log covers only the general contractor's 60 employees. Two trades work a night shift with no designated first aid attendant. At last week's drill, 37 people were unaccounted for at the muster area for 22 minutes, and the fire department's first engine stopped at the wrong gate because the site access map was never sent. During the drill a laborer twisted an ankle on the ramp. The nearest hospital is 18 minutes away and the nearest trauma center 35.

1. Identify and rank the deficiencies in this emergency plan.

Read the worked answer

Ranked by life-safety consequence:

  1. Muster point inside the tower crane's slewing radius and 60 feet from the structure. A dropped load, crane failure, or collapse puts the assembly area inside the hazard zone. Muster areas belong outside all overhead and collapse zones, with a designated alternate.
  2. No site-wide accountability. Only 60 of 220 people are on your roster; subcontractors sign in at their own trailers. In a real event you cannot tell firefighters who is missing. Thirty-seven unaccounted for over 22 minutes is a system failure, not a worker failure.
  3. Single-point alarm. One crane horn is inaudible inside a 14-story structure with running equipment. You need multiple notification methods - air horn, siren, radio, mass text - distinguishable signals for evacuate versus shelter, and backup power.
  4. Night shift uncovered: no designated first aid/CPR responder, no identified incident commander, different lighting and access assumptions.
  5. No external coordination. The fire department had no access map, gate information, hydrant locations, or site contact and stopped at the wrong gate. That alone can add ten minutes to a rescue.
  6. Medical response: 18 minutes to a hospital and 35 to trauma means on-site AEDs, oxygen, trained responders, and a plan for the first ten minutes.
  7. Drill design: no objectives, no timed standards, no critique. The ankle injury during the drill shows the route itself is a hazard.

2. Design the accountability system and drill program, including the measures you would track.

Read the worked answer

Accountability: one site-wide roster.

  • Issue a badge or wristband with a unique number at the gate to every worker, subcontractors included; scan in and out, with a paper backup at each manned gate.
  • Each subcontractor's competent person reports headcount to the muster warden within five minutes of the alarm; the warden reconciles against the electronic roster.
  • Designate zone wardens with two-minute sweep responsibility for assigned floors and areas, and a runner to brief arriving responders.
  • Establish an alternate muster point and a pre-printed accountability board listing each subcontractor and expected count.

Drill program:

  • First drill announced, then unannounced; vary time of day and shift; run one scenario with a blocked primary exit and one night drill per quarter.
  • Set measurable objectives: 100 percent accountability within 10 minutes; structure swept within four minutes; alarm audible in all occupied areas; responders briefed within two minutes of arrival.
  • Debrief within 24 hours with subcontractors present; write corrective actions with owners and due dates; re-drill the failed objectives.
  • Invite the fire department to walk the site, exchange access maps and 24-hour contacts, and run one joint drill a year; keep maps current as gates and material stockpiles change.

Post the plan in the languages actually spoken on site and update it whenever layout, crane position, or shifts change - not annually. Track time-to-accountability, sweep completion, drill participation by subcontractor, and closure of drill corrective actions.

3. Three weeks later a utility worker collapses in a 7-foot-deep excavation with no protective system. A coworker shouts that he is going in. What do you direct?

Read the worked answer

Say no immediately and unambiguously. The instinct to jump in is the leading cause of multiple-fatality trench incidents; a seven-foot wall of soil can trap a worker in seconds, and the would-be rescuer becomes the second victim.

In order:

  1. Stop everyone back from the edge and establish an exclusion zone out to the spoil pile and equipment. No entry of any kind.
  2. Call 911 and identify it as a trench rescue with a trapped or unresponsive worker - address, gate, depth, soil conditions - and request technical rescue.
  3. Keep the worker in view and talk to him if he responds; do not have him try to self-extract if he is pinned.
  4. Lower a lifeline and harness if one is immediately available and can be used without disturbing soil; provide oxygen if trained responders and equipment are on hand.
  5. Control the scene: shut down nearby equipment vibration, move spoil and materials back from the lip, keep vehicles away.
  6. Meet responders with the site map, utility locations, depth, and soil type; flag any atmospheric concern such as a sewer or gas line.
  7. Assign someone to log times and actions for the investigation.

Rescue only by trained, equipped personnel - shoring or shielding, atmospheric testing, and a retrieval system. If your company has a trained team on site under a rescue plan, they may act; otherwise the fire department's technical rescue team is the resource. Afterward, investigate why an unprotected seven-foot excavation existed at all, and make the 24-hour hospitalization report.