ND CDL General Knowledge study materials
ND CDL General Knowledge study resources

Air Leak Test Fails the Applied Test - Dispatch Wants the Load

ND CDL General Knowledge · Put your knowledge to work in context.

All case studies

Air Leak Test Fails the Applied Test - Dispatch Wants the Load

You are assigned a 300-mile run with a 62,000-pound dry van and a 15-minute window to make your appointment. Before leaving, you run the air brake checks with the system fully charged to 120 psi and the engine off. With the brakes released, the gauge drops from 120 to 118 in one minute. Holding the brake pedal fully applied, it drops from 118 to 112 in one minute. Pumping down, the low-pressure warning buzzer sounds at 60 psi and the red trailer air supply knob pops out at 45 psi. The governor cuts the compressor out at 125 psi and back in at 100 psi. There is a faint hiss near the rear of the tractor that you cannot locate. Dispatch is calling, your relief driver is late, and the truck “passed inspection last month.”

1. Which test fails, and what do the numbers actually tell you?

Read the worked answer

Two tests, two different limits:

  • Brakes released: the allowable loss is no more than 2 psi in one minute. You lost 2 psi. That is at the limit - passing, but with no margin, and it already hints at a leak somewhere in the system.
  • Brakes applied and held: the allowable loss is no more than 3 psi in one minute. You lost 6 psi. That is double the limit - a clear failure.

What the failure isolates: holding the brake pedal pressurizes the service side - the treadle valve, the service hoses and gladhands, the brake chambers, and the pushrods. A leak that only shows up with the pedal applied points at that circuit, not at the supply side. The faint hiss supports it.

The low-pressure warning at 60 psi and the trailer air supply knob popping at 45 psi are behaving roughly as designed, so they are not the story. The 6 psi per minute is the story. A gauge that moves that fast while parked will move faster with heat, vibration, and repeated pedal use.

2. Should you take the run? Give the reasoning an inspector would accept.

Read the worked answer

No - and the arithmetic explains why better than “it's the rule.”

Six psi per minute is measured standing still. On the road you add normal air consumption: each brake application, each trailer supply fluctuation, and the compressor only begins rebuilding after the governor drops to the 100 psi cut-in. A grade, a slow down, or a stop-and-go stretch stacks consumption on top of a leak that already exceeds the limit.

If supply pressure falls into the 20–45 psi range, the spring brakes apply on their own - at speed, with no warning beyond the buzzer you already heard. That is an uncontrolled stop in a live lane. Before that point, the tractor protection valve will close to save tractor air, which cuts the trailer off and applies its spring brakes.

The honest framing: the truck cannot hold its air with the brakes applied. Everything else - the appointment, the late relief driver, last month's inspection - is irrelevant to that fact. The correct answer is to red-tag the unit and notify dispatch that the load is not moving on this equipment.

3. What do you do before the truck moves again, and where do you look first?

Read the worked answer

Do not “top off” and go. Diagnose it.

  1. Build to full pressure, shut the engine off, and listen with the pedal released, then with it held. The difference between the two states narrows the search.
  2. Soapy water at the usual suspects: gladhand seals (worn, cracked, or missing), service and emergency hoses at the crimps, the treadle valve under the pedal, chamber diaphragms, and the drain cocks.
  3. Check the trailer too. A trailer leaking on the service side shows up in the tractor's applied test.
  4. Fix or replace, then retest the full sequence: leak test released and applied, low-pressure warning, spring brake application, and a pull test on the trailer.

If the leak is a bad gladhand seal, that is a five-minute repair and a retest. If it is a chamber or a valve, the unit goes to the shop and you take a different tractor. Either way, the write-up says “failed applied leak test, 6 psi/min” - not “air leak, monitor.”