Assisted-Living Fire with Limited Staffing

Fire Officer IV · Put your knowledge to work in context.

All case studies

Assisted-Living Fire with Limited Staffing

You are the battalion chief on duty in a city with three frontline engines, one ladder, and two ALS ambulances. At 02:10, a six-story assisted-living facility with 120 residents reports smoke in a second-floor corridor. The first alarm brings three engines, one ladder, one rescue, and two ambulances. On arrival you find fire in a second-floor storage room, smoke spreading to the third floor, and staff beginning horizontal evacuation. The sprinkler system is operating, but a standpipe valve is damaged. Two residents are unaccounted for. Fourteen firefighters are on scene, including two probationary members. A second alarm is eight minutes away; a third alarm is 15 minutes away. The temperature is 28°F. The building's alarm system has a history of nuisance alarms, and the last preplan is four years old.

1. Establish command and set initial priorities with the resources on scene.

Read the worked answer

Assume command and establish a fixed command post. Give a concise size-up: six-story assisted living, fire on two, smoke on three, residents in place, sprinklers operating, standpipe damaged. Priorities: life safety, incident stabilization, property conservation-but with 120 residents and two missing, rescue and evacuation come first. Assign the first engine to attack the storage-room fire with a 1¾-inch line from a reliable water source, not the damaged standpipe; assign the ladder to third-floor evacuation and access; assign the rescue and ambulances to triage and transport; keep one crew as RIT. Order a second alarm immediately, not after the fire grows, and request additional medic units and a building maintenance representative. Establish staging and an accountability officer. Because two members are probationary, pair them with experienced firefighters and do not assign them to the fire floor without supervision.

2. Decide between rescue and fire attack, and describe the benchmarks and additional resources you would request.

Read the worked answer

Rescue versus attack: the fire is small and sprinkler-controlled, so a coordinated attack can protect the evacuation path; however, two missing residents and smoke on three mean search cannot wait. I would assign a search crew to the third floor with a charged line for protection, and keep the attack on the storage room to prevent extension. Benchmarks: primary search of the fire floor and floor above within the first 10 minutes; water on fire within 5; all occupants accounted for or evacuated; second alarm on scene. If the standpipe is damaged, use a stairwell stretch or outside master stream only if safe. Request a third alarm if fire extends or if evacuation of 120 residents exceeds available staff. Notify the dispatcher of a mass-casualty or evacuation status and request the Red Cross and building management.

3. Address firefighter health and safety and post-incident issues, including accountability, rehab, and community relations.

Read the worked answer

Safety: establish rehab early because of cold at 28°F, smoke, and bulky PPE; rotate crews, monitor vital signs, and provide warming. Accountability must include all occupants and all firefighters; the damaged standpipe and nuisance-alarm history raise the risk of confusion, so use clear tactical channels. Post-incident: preserve the alarm and sprinkler records, conduct a critique, and check the preplan-four years old is too old for a 120-resident facility. Notify the fire prevention bureau for a follow-up inspection of the standpipe and alarm system. Community relations: coordinate with the facility, families, and PIO; avoid speculation about cause. If a resident is injured or lost, ensure the investigation and family notifications are handled with legal and administrative support.