NM Journeyman Plumber: Drain, Waste, and Vent Systems

NM Journeyman Plumber · Work through your exam, one topic at a time.

All guide sections

Drain, Waste, and Vent Systems

Drain, Waste, and Vent Systems is the largest technical area: slope, fixture units, trap arms, venting, cleanouts, and the separations that keep sewage gas out of buildings. The exam tests whether a drain can carry its load and whether every trap has a compliant vent.

Core rules

  • Horizontal drainage slope is typically 1/4 inch per foot for 2-1/2-inch and smaller pipe and 1/8 inch per foot for 3-inch and larger pipe, subject to the adopted table.
  • Each trap must be vented; a vent must rise at least 6 inches above the fixture flood-level rim before offsetting horizontally.
  • Trap-arm length is limited by trap size; the UPC table gives longer allowances as trap size increases.
  • Cleanouts are required at the base of stacks, at changes of direction, and at long horizontal runs.
  • A vent may not serve as a drain, and a drain may not be used as a vent.

Worked example

A 1-1/2-inch lavatory trap arm measures 7 feet from the trap to the vent. The UPC trap-arm table allows 6 feet for a 1-1/2-inch trap. The installation fails. Reasoning: the trap arm is measured along the pipe from the trap weir to the vent connection; adding a horizontal offset or fittings only increases the developed length. The fix is to relocate the vent closer or redesign the branch, not simply to call the arm “short.”

Traps that cost marks

  • Measuring trap-arm length in a straight line instead of along the pipe.
  • Offsetting a vent below the flood-level rim.
  • Using a 2-inch vent for a 3-inch stack without checking the vent table.
  • Forgetting cleanouts at the base of a stack.