Smoldering Warehouse: Air Monitoring and Respirator Limits

OSHA 15-Hr Disaster Site Worker · Put your knowledge to work in context.

All case studies

Smoldering Warehouse: Air Monitoring and Respirator Limits

A fire-damaged warehouse still has smoldering pallets in the rear. A two-person crew is to enter for 30 minutes to retrieve inventory records and shut a water valve. Before entry, a direct-reading meter at the door shows O2 20.4%, CO 85 ppm, H2S 3 ppm, LEL 4%, and VOCs 120 ppm as isobutylene. Visible ash and smoke haze are present, and the floor is covered with charred debris. One worker wears a half-face air-purifying respirator with P100 and organic vapor cartridges; he has not been fit-tested and has three days of stubble. The other has an N95 and no cartridge respirator. The site has no supplied-air equipment on hand, and the nearest fire department is 25 minutes away. The meter was calibrated 14 months ago, and the crew plans to rely on one reading at the doorway.

1. Interpret the readings and decide whether the entry should proceed.

Read the worked answer

The readings argue against entry with the proposed PPE. Oxygen is acceptable at 20.4%, and LEL 4% is below the common 10% alarm, but CO at 85 ppm is above the NIOSH REL of 35 ppm TWA and the ACGIH TLV of 25 ppm; it indicates active combustion and can cause headache and dizziness. H2S at 3 ppm is below the 10 ppm 10-minute ceiling but shows decomposition. VOCs at 120 ppm as isobutylene indicate organic vapors, and visible smoke and ash mean particulates. The doorway reading is a single point and may not represent the rear where pallets are smoldering. A half-face APR with P100 and organic vapor cartridges does not remove CO, and the worker has not been fit-tested and has stubble, so a tight seal is unreliable. The second worker has only an N95. Without supplied air, ventilation, and continuous monitoring, do not enter. Ventilate first, monitor inside from the doorway with a calibrated meter, and if entry is essential use SCBA or supplied-air respirators with an attendant and a rescue plan.

2. What respiratory protection is appropriate, and what program elements are missing?

Read the worked answer

CO cannot be filtered by an air-purifying cartridge; it requires supplied air or SCBA. The P100 and organic vapor cartridges are appropriate only for particulates and many organic vapors, not CO, and only if the atmosphere is not oxygen-deficient or immediately dangerous to life or health. A tight-fitting half-face requires a medical evaluation, fit test, training, and no facial hair at the sealing surface; three days of stubble makes the seal unreliable. The N95 is inadequate for vapors and also requires fit testing. Missing program elements include a written respiratory protection program, medical clearance, annual fit testing, user seal checks, a cartridge change schedule, cleaning and storage, and training. If monitoring shows CO above the REL or rising, or if entry is into an IDLH atmosphere, use SCBA. Because the fire department is 25 minutes away, the rescue plan must be self-sufficient: two-person entry, an attendant, communications, and retrieval capability.

3. What air monitoring plan would you require before and during entry?

Read the worked answer

Use a calibrated, bump-tested direct-reading meter capable of O2, CO, H2S, LEL, and VOCs. Calibration was 14 months ago, so calibrate and bump test before use. Monitor at the doorway, then at the breathing zone just inside, then at the rear near the smoldering pallets; do not rely on one doorway reading. Set alarms for O2 below 19.5%, CO at 35 ppm or lower, H2S at 10 ppm, LEL at 10%, and VOC alarms based on the cartridge and exposure limits. Assign one person to monitor continuously and record readings every few minutes. Establish evacuation triggers and a communication method. Because conditions can change with smoldering debris, monitor during the entire entry, not just before. If the meter alarms or readings rise, evacuate and reassess. Also monitor outside the entry to protect the attendant and to detect migration of CO into occupied areas.