PECB ISO 50001 Foundation · Put your knowledge to work in context.

All case studies

Scope Boundaries and a Significant Energy Use Without Metering

Helio Components Group operates two production sites, a headquarters office, a leased warehouse and an outsourced logistics fleet. Electricity use is 78% at the two production sites, 9% at the warehouse, 5% at headquarters and 8% in logistics. The energy team proposes an EnMS scope covering only the two production sites, arguing that offices and storage are not 'core' and that logistics is outsourced. At Site A, compressed air is estimated at 22% of site electricity but has no dedicated meter; the estimate comes from a 2019 consultant study. Site B's heat-treatment furnace is metered and accounts for 31% of site energy. Top management wants certification within nine months and asks whether the proposed exclusions are acceptable, how to treat the warehouse, and whether compressed air must be addressed. The certification body has not yet been selected.

1. Are the proposed exclusions acceptable for an EnMS scope? Explain.

Read the worked answer

The scope is a management decision, but it must be transparent and must not be chosen simply to avoid inconvenient energy uses. Excluding headquarters and the warehouse may be acceptable if they are genuinely outside the boundary and the organization can justify the boundary. However, the warehouse is leased and uses 9% of electricity; if the organization controls its operation, it is likely part of the site and should be included or explicitly justified. Outsourced logistics can be excluded from the EnMS boundary if the organization does not control the fleet, but the energy use should still be considered in procurement and transport decisions. The key tests are control, influence and significance. The scope must be documented, and the certification body will expect the exclusion rationale. Excluding a site with significant energy use without analysis undermines the credibility of the EnMS.

2. How should compressed air at Site A be treated?

Read the worked answer

Compressed air at an estimated 22% of site electricity is a significant energy use by any reasonable threshold, even if the figure is based on an old study. The organization should not rely on a 2019 estimate for a current SEU. Install a dedicated meter or use temporary logging to establish current consumption, then update the energy review. Identify improvement opportunities: leaks, pressure setpoints, idle running, heat recovery and control. Include the SEU in the action plan with an owner and target. The lack of metering is itself a gap in the monitoring plan; the organization cannot demonstrate improvement without data. Until metering is in place, use the estimate cautiously and state its uncertainty. The certification auditor will look for evidence that significant energy uses are identified and addressed, not necessarily that every one has a permanent meter on day one.

3. What should be documented about the scope and boundaries?

Read the worked answer

Document the physical and organizational boundaries, the sites and facilities included and excluded, and the rationale for each exclusion. Include a map or list of energy uses and the criteria used to decide significance. Record who controls each included facility and how energy data are collected. For the warehouse, state whether it is included and why; for logistics, explain the control relationship. Record the energy review results for each site and the SEUs, including compressed air and the furnace. Keep the scope statement consistent with the action plan and objectives. The documentation should allow an auditor to see that the boundary was chosen on a defensible basis, not to minimize the number of sites audited.