CIRCC key terms
CIRCC · Get comfortable with the vocabulary.
- Femoral artery access
- Related: Radial artery access, Retroperitoneal hemorrhage, Sheath
Puncturing the common femoral artery to insert catheters for left heart catheterization and coronary angiography. Correct placement relative to the femoral head and bifurcation reduces bleeding and vascular complications.
- Radial artery access
- Related: Femoral artery access, Allen test, Radial artery spasm
Entering the radial artery at the wrist for catheter procedures, favored for lower bleeding risk and earlier ambulation. A patent palmar arch should be confirmed before puncture to protect hand perfusion.
- Allen test
- Related: Radial artery access, Radial artery spasm
A bedside check of collateral hand circulation in which the radial and ulnar arteries are compressed and release of the ulnar artery is observed for reperfusion. It helps confirm a safe radial approach.
- Radial artery spasm
- Related: Radial artery access, Sheath
Narrowing of the radial artery during catheter manipulation, causing pain and resistance to catheter movement. It is prevented with vasodilator cocktails and gentle technique and treated with additional vasodilators and patience.
- Sheath
- Related: French size, Femoral artery access, Hemostasis
A short plastic tube placed in the artery or vein that keeps a channel open so catheters can be passed repeatedly with less vessel trauma. Its size is given in French units.
- French size
- Related: Sheath, Guiding catheter
A unit describing catheter and sheath diameter, where one French equals one-third of a millimeter. Knowing conversions helps the operator select equipment that fits the vessel and the planned procedure.
- Guiding catheter
- Related: Diagnostic catheter, Guidewire, French size
A large-lumen catheter shaped to seat in a coronary ostium and provide a stable conduit for wires, balloons, and stents during intervention. Its shape is chosen to match the coronary anatomy being treated.
- Diagnostic catheter
- Related: Guiding catheter, Contrast angiography
A catheter used to engage coronary ostia and inject contrast for angiography, typically with a smaller lumen and softer tip than a guiding catheter. Different curves fit different aortic and coronary shapes.
- Guidewire
- Related: Guiding catheter, Intravascular ultrasound
A thin flexible wire passed through vessels to steer and support catheters and devices to a target lesion. Its tip design and stiffness affect crossing ability and safety.
- Contrast angiography
- Related: Diagnostic catheter, Contrast-induced nephropathy, Coronary stenosis
Imaging of blood vessels by injecting radiopaque contrast through a catheter while recording X-ray images. It shows lumen shape, stenosis severity, and flow, and requires attention to contrast volume and kidney risk.
- Coronary stenosis
- Related: Fractional flow reserve, Percutaneous coronary intervention, Contrast angiography
A narrowing of a coronary artery lumen, usually from atherosclerotic plaque, that can limit blood flow to heart muscle. Severity is judged by angiography and, when needed, by pressure-based measurements.
- Fractional flow reserve
- Related: Coronary stenosis, Guidewire, Percutaneous coronary intervention
A pressure-wire measurement comparing pressure distal to a coronary narrowing with aortic pressure during maximal hyperemia. A low ratio indicates the stenosis limits flow and may benefit from revascularization.
- Percutaneous coronary intervention
- Related: Stent, Balloon angioplasty, Coronary stenosis
Treating coronary narrowing through the skin using catheters, balloons, and stents rather than surgery. It aims to restore blood flow and relieve ischemia, with antiplatelet therapy and complication vigilance as key supports.
- Balloon angioplasty
- Related: Stent, Percutaneous coronary intervention, Coronary dissection
Inflating a balloon catheter within a narrowed artery to stretch the plaque and enlarge the lumen. It is often followed by stent placement because plain balloon dilation can recoil or tear the vessel.
- Stent
- Related: Balloon angioplasty, Stent thrombosis, Percutaneous coronary intervention
A small mesh tube deployed in an artery to hold it open after balloon dilation. Drug-eluting types release medication to reduce tissue regrowth, and correct sizing and expansion affect outcomes.
- Stent thrombosis
- Related: Stent, Dual antiplatelet therapy
Clot forming inside a deployed stent, which can abruptly block the artery and cause a heart attack. It is linked to incomplete stent expansion, poor antiplatelet adherence, and premature discontinuation of medication.
- Coronary dissection
- Related: Balloon angioplasty, Coronary perforation
A tear in the inner lining of a coronary artery that lets blood track within the vessel wall and can narrow or occlude the lumen. It may follow catheter trauma or balloon inflation and sometimes needs stenting.
- Coronary perforation
- Related: Cardiac tamponade, Coronary dissection
A puncture or rupture of a coronary artery wall during a catheter procedure, allowing blood to leak outside the vessel. It can cause rapid cardiac tamponade and requires prompt balloon tamponade and sometimes covered stents or surgery.
- Cardiac tamponade
- Related: Coronary perforation, Pericardiocentesis
Compression of the heart by fluid or blood accumulating in the pericardial sac, impairing filling and lowering blood pressure. In the catheterization lab it is a feared consequence of perforation and needs urgent drainage.
- Pericardiocentesis
- Related: Cardiac tamponade
Needle drainage of fluid from the pericardial sac, often guided by ultrasound or fluoroscopy. It relieves tamponade and can stabilize a patient after a procedure-related perforation.
- Retroperitoneal hemorrhage
- Related: Femoral artery access, Hemostasis
Bleeding into the space behind the abdominal cavity, often after a femoral puncture that is too high. It may present with back or flank pain and falling blood pressure without visible groin swelling.
- Hemostasis
- Related: Sheath, Retroperitoneal hemorrhage, Radial artery access
The process of stopping bleeding at an access site, achieved by manual compression or a closure device. Effective hemostasis and appropriate bed rest reduce rebleeding and vascular complications after sheath removal.
- Contrast-induced nephropathy
- Related: Contrast angiography, Hydration protocol
A rise in serum creatinine after iodinated contrast exposure, reflecting acute kidney injury. Risk is reduced by limiting contrast volume, ensuring hydration, and identifying patients with preexisting kidney disease or diabetes.
- Hydration protocol
- Related: Contrast-induced nephropathy
Planned intravenous fluid administration before and after contrast exposure to support kidney perfusion and reduce injury risk. Saline is commonly used, with volume adjusted for heart failure and kidney function.
- Dual antiplatelet therapy
- Related: Stent thrombosis, Stent
Combined use of aspirin and a P2Y12 inhibitor to prevent clot formation after stent placement. Adherence and correct timing around procedures are critical because interruption raises the risk of stent thrombosis.
- Left ventricular ejection fraction
- Related: Left ventriculography, Hemodynamic monitoring
The percentage of blood in the left ventricle ejected with each beat, a core measure of pumping function. It is often assessed during catheterization and guides risk assessment and device decisions.
- Left ventriculography
- Related: Left ventricular ejection fraction, Contrast angiography
Injecting contrast into the left ventricle to visualize its size, wall motion, and valve function during catheterization. It helps identify regional wall motion abnormalities and estimate ejection fraction.
- Hemodynamic monitoring
- Related: Right heart catheterization, Cardiac output, Left ventricular ejection fraction
Measuring pressures and flows within the heart and vessels using catheters and transducers to assess function and guide therapy. It includes chamber pressures, cardiac output, and vascular resistance calculations.
- Right heart catheterization
- Related: Hemodynamic monitoring, Cardiac output, Pulmonary capillary wedge pressure
Passing a catheter through the venous system into the right heart and pulmonary artery to measure pressures and cardiac output. It helps evaluate pulmonary hypertension, shock, and heart failure.
- Cardiac output
- Related: Hemodynamic monitoring, Right heart catheterization
The volume of blood pumped by the heart per minute, equal to stroke volume times heart rate. It is measured or calculated during catheterization to assess circulatory adequacy and guide treatment.
- Pulmonary capillary wedge pressure
- Related: Right heart catheterization, Hemodynamic monitoring
A pressure obtained by inflating a balloon on a pulmonary artery catheter to estimate left atrial pressure. It reflects left-sided filling pressures and helps distinguish causes of dyspnea and shock.
- Coronary sinus
- Related: Right heart catheterization, Coronary anatomy
A large vein on the back of the heart that collects cardiac venous blood and drains into the right atrium. Its anatomy is relevant to catheter procedures such as retrograde access and cardiac vein mapping.
- Coronary anatomy
- Related: Coronary stenosis, Guiding catheter, Coronary sinus
The branching pattern of the right and left coronary arteries that supply heart muscle, including the left main, left anterior descending, circumflex, and right coronary arteries. Knowing typical and variant patterns guides catheter selection and interpretation.
- Cardiac conduction system
- Related: Bradycardia, Coronary anatomy
Specialized heart tissue that generates and conducts electrical impulses, including the sinoatrial node, atrioventricular node, and His-Purkinje network. Its function coordinates chamber contraction and is relevant to rhythm complications during procedures.
- Bradycardia
- Related: Cardiac conduction system, Vasovagal reaction
A heart rate slower than normal, which can reduce cardiac output and cause dizziness or fainting. During catheter procedures it may follow vagal stimulation or coronary injection and may require atropine or pacing.
- Vasovagal reaction
- Related: Bradycardia, Hemodynamic monitoring
A reflex causing sudden slowing of the heart rate and widening of blood vessels, leading to low blood pressure and fainting. It can occur with pain, anxiety, or groin manipulation and is managed with fluids and positioning.
- Radiation safety
- Related: Fluoroscopy, Lead apron
Practices that limit patient and staff exposure to X-rays, including minimizing fluoroscopy time, using collimation, and wearing shielding. Distance and time are the most effective ways to reduce dose.
- Fluoroscopy
- Related: Radiation safety, Contrast angiography, Lead apron
Real-time X-ray imaging used to guide catheters and devices inside the body. It allows continuous visualization during procedures, and dose management is an essential part of its safe use.
- Lead apron
- Related: Radiation safety, Fluoroscopy
Protective garment worn by catheterization laboratory staff to absorb scattered X-rays and reduce body dose. Proper fit and storage matter because damage or poor fit can leave gaps in protection.
- Intravascular ultrasound
- Related: Guidewire, Stent, Coronary stenosis
A catheter-based ultrasound probe that images the inside of vessels and plaque structure. It helps assess lesion severity, vessel size, and stent expansion beyond what angiography alone shows.