ABC Biological Industrial Waste Treatment Operator flashcards
ABC Biological Industrial Waste Treatment Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- BOD5
- Biochemical oxygen demand over 5 days at 20°C; measures biodegradable organic matter in wastewater.
- COD
- Chemical oxygen demand; oxygen equivalent of organic matter oxidized by dichromate; includes non-biodegradable organics.
- F/M ratio
- Food-to-microorganism ratio; mass of BOD applied per mass of MLVSS per day; typical 0.2–0.5 day⁻¹.
- SVI
- Sludge volume index; volume of settled sludge after 30 minutes per gram of MLSS; 80–150 mL/g indicates good settling.
- MLSS
- Mixed liquor suspended solids; concentration of solids in aeration tank; typical 2000–4000 mg/L.
- SRT
- Solids retention time (sludge age); mass of solids in system divided by mass wasted per day; controls nitrification.
- Nitrification
- Biological oxidation of ammonia to nitrite then nitrate by autotrophic bacteria; consumes alkalinity and oxygen.
- Denitrification
- Anoxic conversion of nitrate to nitrogen gas by heterotrophic bacteria; requires carbon source and low oxygen.
- Primary clarifier
- Settling tank that removes settleable solids; typical removal: 50–70% TSS and 25–40% BOD.
- Equalization basin
- Tank that dampens flow and load variations; provides mixing and typical HRT of 4–24 hours.
- Grit removal
- Preliminary treatment removing dense particles >0.2 mm to prevent abrasion and accumulation in downstream processes.
- Trickling filter
- Fixed-film biological reactor with wastewater trickling over media; organic loading 0.3–2.5 kg BOD/m³·d.
- Aerated lagoon
- Biological treatment basin with mechanical aeration; HRT 5–10 days; power density 1–3 W/m³.
- MBBR
- Moving bed biofilm reactor; uses plastic carriers with biofilm; fill fraction 30–70% for treatment.
- Facultative lagoon
- Lagoon with aerobic surface and anaerobic bottom; depth 1.5–2.5 m; loading 20–50 kg BOD/ha·d.
- Pretreatment standards
- Regulations limiting industrial pollutants (e.g., metals, cyanide) discharged to publicly owned treatment works.
- Shock load
- Sudden increase in flow or organic concentration; can upset biological treatment; mitigated by equalization.
- Nutrient addition
- Addition of nitrogen and phosphorus to industrial wastewater to maintain BOD:N:P ratio of 100:5:1 for biomass.
- Anaerobic digestion
- Biological decomposition of sludge in absence of oxygen; produces methane; reduces volatile solids 40–60%.
- Sludge dewatering
- Process (e.g., belt press, centrifuge) that removes water from sludge to produce cake with 15–30% solids.
- Gravity thickener
- Tank that increases sludge solids concentration from 1–2% to 3–6% by settling.
- CT concept
- Disinfection efficacy product of disinfectant concentration (mg/L) and contact time (min); typical CT 15–30 mg·min/L.
- UV disinfection
- Inactivation of pathogens by ultraviolet light; dose 30–40 mJ/cm²; requires low TSS and high UV transmittance.
- Dechlorination
- Removal of residual chlorine using sulfur dioxide or bisulfite; dose about 1 mg/L per 1 mg/L chlorine.
- Confined space entry
- Entry into a permit-required space; test oxygen (19.5–23.5%), flammables (<10% LEL), and toxics before entry.
- H2S
- Hydrogen sulfide; toxic gas with rotten egg odor; immediately dangerous at >100 ppm; monitor in sewers and digesters.
- LOTO
- Lockout/tagout; safety procedure to isolate energy sources during maintenance; verify zero energy state.
- Composite sampling
- Sample collected over time or flow; used for variable flows; refrigerate at 4°C; preserves sample integrity.
- BOD5 analysis
- Laboratory test: seed, dilute sample, incubate 5 days at 20°C, measure dissolved oxygen depletion.
- COD analysis
- Digestion with dichromate at 150°C for 2 hours; measure absorbance; mercury sulfate masks chloride interference.
- TSS analysis
- Filter sample through glass fiber filter, dry at 103–105°C, and weigh; VSS obtained by ignition at 550°C.
- Fecal coliform
- Indicator bacteria for fecal contamination; typical effluent limit 200 CFU/100 mL; analyzed by membrane filtration.