ABC Biological Industrial Waste Treatment Operator study materials
ABC Biological Industrial Waste Treatment Operator study resources

ABC Biological Industrial Waste Treatment Operator flashcards

ABC Biological Industrial Waste Treatment Operator · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

BOD5
Biochemical oxygen demand over 5 days at 20°C; measures biodegradable organic matter in wastewater.
COD
Chemical oxygen demand; oxygen equivalent of organic matter oxidized by dichromate; includes non-biodegradable organics.
F/M ratio
Food-to-microorganism ratio; mass of BOD applied per mass of MLVSS per day; typical 0.2–0.5 day⁻¹.
SVI
Sludge volume index; volume of settled sludge after 30 minutes per gram of MLSS; 80–150 mL/g indicates good settling.
MLSS
Mixed liquor suspended solids; concentration of solids in aeration tank; typical 2000–4000 mg/L.
SRT
Solids retention time (sludge age); mass of solids in system divided by mass wasted per day; controls nitrification.
Nitrification
Biological oxidation of ammonia to nitrite then nitrate by autotrophic bacteria; consumes alkalinity and oxygen.
Denitrification
Anoxic conversion of nitrate to nitrogen gas by heterotrophic bacteria; requires carbon source and low oxygen.
Primary clarifier
Settling tank that removes settleable solids; typical removal: 50–70% TSS and 25–40% BOD.
Equalization basin
Tank that dampens flow and load variations; provides mixing and typical HRT of 4–24 hours.
Grit removal
Preliminary treatment removing dense particles >0.2 mm to prevent abrasion and accumulation in downstream processes.
Trickling filter
Fixed-film biological reactor with wastewater trickling over media; organic loading 0.3–2.5 kg BOD/m³·d.
Aerated lagoon
Biological treatment basin with mechanical aeration; HRT 5–10 days; power density 1–3 W/m³.
MBBR
Moving bed biofilm reactor; uses plastic carriers with biofilm; fill fraction 30–70% for treatment.
Facultative lagoon
Lagoon with aerobic surface and anaerobic bottom; depth 1.5–2.5 m; loading 20–50 kg BOD/ha·d.
Pretreatment standards
Regulations limiting industrial pollutants (e.g., metals, cyanide) discharged to publicly owned treatment works.
Shock load
Sudden increase in flow or organic concentration; can upset biological treatment; mitigated by equalization.
Nutrient addition
Addition of nitrogen and phosphorus to industrial wastewater to maintain BOD:N:P ratio of 100:5:1 for biomass.
Anaerobic digestion
Biological decomposition of sludge in absence of oxygen; produces methane; reduces volatile solids 40–60%.
Sludge dewatering
Process (e.g., belt press, centrifuge) that removes water from sludge to produce cake with 15–30% solids.
Gravity thickener
Tank that increases sludge solids concentration from 1–2% to 3–6% by settling.
CT concept
Disinfection efficacy product of disinfectant concentration (mg/L) and contact time (min); typical CT 15–30 mg·min/L.
UV disinfection
Inactivation of pathogens by ultraviolet light; dose 30–40 mJ/cm²; requires low TSS and high UV transmittance.
Dechlorination
Removal of residual chlorine using sulfur dioxide or bisulfite; dose about 1 mg/L per 1 mg/L chlorine.
Confined space entry
Entry into a permit-required space; test oxygen (19.5–23.5%), flammables (<10% LEL), and toxics before entry.
H2S
Hydrogen sulfide; toxic gas with rotten egg odor; immediately dangerous at >100 ppm; monitor in sewers and digesters.
LOTO
Lockout/tagout; safety procedure to isolate energy sources during maintenance; verify zero energy state.
Composite sampling
Sample collected over time or flow; used for variable flows; refrigerate at 4°C; preserves sample integrity.
BOD5 analysis
Laboratory test: seed, dilute sample, incubate 5 days at 20°C, measure dissolved oxygen depletion.
COD analysis
Digestion with dichromate at 150°C for 2 hours; measure absorbance; mercury sulfate masks chloride interference.
TSS analysis
Filter sample through glass fiber filter, dry at 103–105°C, and weigh; VSS obtained by ignition at 550°C.
Fecal coliform
Indicator bacteria for fecal contamination; typical effluent limit 200 CFU/100 mL; analyzed by membrane filtration.