Wastewater Collection Operator Class I key terms
Wastewater Collection Operator Class I · Get comfortable with the vocabulary.
- Sanitary sewer
- Related: Infiltration, Inflow, Surcharge
A pipe network that carries domestic and industrial wastewater from buildings to a treatment plant. It is designed to exclude stormwater, surface water, and groundwater so flows stay within its capacity.
- Infiltration
- Related: Inflow, Sanitary sewer
Groundwater that seeps into a sewer system through cracks, broken joints, deteriorated pipe, and faulty manhole walls. It raises dry-weather flows and adds clear water the plant must treat.
- Inflow
- Related: Infiltration, Smoke testing
Stormwater, drainage, or other water that enters a sewer directly through roof drains, sump pumps, manhole covers, and cross connections. Unlike infiltration, it arrives quickly during rain events.
- Invert
- Related: Surcharge
The lowest inside surface of a pipe or channel at a given cross section. Operators use invert elevations to confirm slope and to measure how deep a sewer line lies.
- Force main
- Related: Wet well, Surcharge
A pressurized pipeline that carries wastewater discharged by pumps, usually from a lift station to a gravity sewer or treatment plant. Flow is driven by pressure, not by gravity.
- Surcharge
- Related: Sanitary sewer overflow, Infiltration
A condition where flow exceeds a sewer's capacity and the water level rises above the pipe crown, putting the line under pressure. Surcharging can push wastewater out through manholes.
- Smoke testing
- Related: Inflow, Infiltration
A technique where non-toxic smoke is blown into a sewer line and escaping smoke reveals cracks, illegal connections, and storm drains tied into the system. Crews notify the public before testing.
- Hydrogen sulfide
- Related: Atmospheric monitoring, Permit-required confined space
A toxic, corrosive gas formed when wastewater goes septic and sulfate is reduced under anaerobic conditions. It causes odors, attacks concrete pipe, and can be deadly in confined spaces.
- FOG
- Related: Surcharge, Sanitary sewer overflow
Fats, oils, and grease that enter sewers from kitchens and food businesses. They cool and congeal on pipe walls, narrowing the line and causing blockages and overflows.
- Centrifugal pump
- Related: Cavitation, Net positive suction head (NPSH), Pump curve
A pump that uses a spinning impeller to throw water outward into a casing, converting speed into pressure. It is the most common type used for wastewater and is best for high flows at low head.
- Positive displacement pump
- Related: Centrifugal pump, Force main
A pump that moves a set volume of liquid each cycle by trapping it and pushing it forward with a piston, diaphragm, or rotary element. It suits thick sludges and low flows at high pressure.
- Cavitation
- Related: Net positive suction head (NPSH), Centrifugal pump
The formation and collapse of vapor bubbles in a pump when local pressure drops below the liquid's vapor pressure. It causes noise, vibration, and pitting damage to the impeller and reduces capacity.
- Net positive suction head (NPSH)
- Related: Cavitation, Centrifugal pump
The absolute pressure at a pump's suction, expressed in feet of liquid, above the liquid's vapor pressure. Too little available NPSH causes cavitation and loss of capacity.
- Total dynamic head
- Related: Pump curve, Force main
The total energy a pump must add to move liquid through a system, combining static lift, discharge elevation, and friction losses in pipe and fittings. It is measured in feet of liquid.
- Pump curve
- Related: Total dynamic head, Centrifugal pump
A graph supplied by the manufacturer showing the relationship between flow rate and head, plus efficiency and power, for a given pump at a set speed. Operators use it to match a pump to the system.
- Check valve
- Related: Force main, Wet well
A valve that lets flow pass in one direction only and closes automatically when flow reverses. It protects pumps from backspin and keeps wastewater from flowing back into a wet well.
- Wet well
- Related: Check valve, Variable frequency drive
The chamber that receives incoming wastewater and holds it so pumps can draw from it. Pump start and stop levels in the wet well control the operating cycle.
- Variable frequency drive
- Related: Wet well, Centrifugal pump
An electronic controller that changes the speed of an electric motor by varying the frequency and voltage supplied to it. It lets pumps match flow demand and reduces energy use and starting stress.
- Permit-required confined space
- Related: Atmospheric monitoring, Lockout/tagout, Hydrogen sulfide
A space large enough to enter, with limited access, not designed for continuous occupancy, and containing a serious hazard such as a hazardous atmosphere, engulfment, or entrapment. Entry requires a written permit and an attendant.
- Lockout/tagout
- Related: Permit-required confined space
A procedure for isolating energy sources before work on machinery so equipment cannot start unexpectedly. Each worker applies a personal lock and tag, and the equipment is verified de-energized.
- Lower explosive limit
- Related: Atmospheric monitoring
The lowest concentration of a flammable gas or vapor in air that will ignite when a spark is present. Monitors read in percent LEL, and readings of ten percent or more mean do not enter.
- Oxygen deficiency
- Related: Atmospheric monitoring, Permit-required confined space
An atmosphere containing less than 19.5 percent oxygen by volume, the minimum considered safe for entry. Low oxygen can cause confusion and collapse without warning.
- Trench protective system
An engineered method such as sloping, benching, shoring, or a trench shield used to prevent cave-ins in an excavation. Trenches five feet deep or more require a protective system.
- Bloodborne pathogens
Disease-causing microorganisms carried in blood and body fluids, such as hepatitis B and HIV. Workers exposed to sewage or medical waste follow an exposure control plan and use protective equipment.
- Safety data sheet
- Related: Hydrogen sulfide
A standardized document from a chemical manufacturer listing hazards, handling precautions, first aid, and spill response for a product. Workers must be able to find one for every hazardous chemical on site.
- Atmospheric monitoring
- Related: Permit-required confined space, Lower explosive limit, Oxygen deficiency
Testing the air inside a confined space for oxygen, flammable gas, hydrogen sulfide, and carbon monoxide before entry and continuously while anyone is inside. Monitors are calibrated and bump tested regularly.
- Clean Water Act
- Related: NPDES permit, Pretreatment program
The federal law that governs water pollution in the United States. It set the framework for discharge permits, water quality standards, and funding for wastewater treatment and collection systems.
- NPDES permit
- Related: Clean Water Act
The National Pollutant Discharge Elimination System permit required by the Clean Water Act for any point-source discharge of pollutants to surface waters. Permits set limits, monitoring, and reporting requirements.
- Sanitary sewer overflow
- Related: Combined sewer overflow, Surcharge, CMOM
A release of untreated wastewater from a sanitary sewer system before it reaches the treatment plant. Overflows can be caused by blockages, infiltration, equipment failure, or excess flow, and most states require reporting.
- Combined sewer overflow
- Related: Sanitary sewer overflow, Surcharge
A discharge of mixed stormwater and raw wastewater from a combined sewer when a rain event exceeds the system's capacity. These overflows are regulated and often addressed through long-term control plans.
- CMOM
- Related: Sanitary sewer overflow, Sewer use ordinance
Capacity, Management, Operations, and Maintenance, an EPA framework for keeping sanitary sewers in good condition. It calls for proactive programs covering flow capacity, maintenance, and overflow response.
- Pretreatment program
- Related: Sewer use ordinance, Clean Water Act
A regulatory program that controls what industrial users may discharge into a publicly owned sewer so the treatment plant stays compliant and sludge stays usable. It relies on permits, inspections, and local limits.
- Sewer use ordinance
- Related: Pretreatment program, FOG
The local law that sets the rules for connecting to and discharging into a municipal sewer, including prohibited wastes, fees, and permit requirements. It is the legal basis for local enforcement.
- Operator certification
A state-issued credential showing that a wastewater operator has met education, experience, and examination requirements for a given grade. Certification must usually be renewed with continuing education.