Wastewater Treatment Operator Class I study materials
Wastewater Treatment Operator Class I study resources

Wastewater Treatment Operator Class I cheat sheet

Wastewater Treatment Operator Class I · Keep the key ideas within reach.

Quick reference

Safety Practices and Hazard Awareness

  • A permit-required confined space has limited entry/exit, is not meant for continuous occupancy, and contains a serious hazard; entry requires a permit, entrant, attendant, and entry supervisor.

  • Acceptable entry atmosphere: oxygen 19.5-23.5%, flammable gas below 10% of the LEL, hydrogen sulfide below 10 ppm, carbon monoxide below 35 ppm; test before entry and continuously while inside.

  • Hydrogen sulfide is heavier than air, has a rotten-egg odor at low concentrations, deadens the sense of smell quickly, and is immediately dangerous to life at 100 ppm; odor is never a valid warning.

  • Methane has a lower explosive limit of 5% and an upper explosive limit of 15% in air; chlorine gas is about 2.5 times heavier than air and settles in low areas.

  • Lockout/tagout: isolate every energy source, apply personal locks and tags, release stored energy, and verify a zero-energy state before maintenance begins.

  • Excavations 5 ft (1.5 m) deep or more require a protective system; spoil piles and equipment are kept back at least 2 ft from the trench edge.

  • Mixing sodium hypochlorite with acid releases chlorine gas; adding ammonia-based chemicals to chlorine forms chloramines; never store oxidizers next to fuels or solvents.

  • Fall protection is required at 4 ft in general industry; ladders, guards, and grating must be maintained around tanks, clarifiers, and wet wells.

Quick reference

Rules, Regulations, and Administration

  • The Clean Water Act (1972) created the NPDES permit program; 40 CFR Part 122 contains the NPDES regulations and Part 123 covers state program approval.

  • Secondary treatment standards: 30-day average BOD5 30 mg/L and TSS 30 mg/L, 7-day average 45 mg/L for each, with pH held between 6 and 9.

  • Discharge Monitoring Reports (DMRs) are submitted monthly, are signed by a responsible official, and must include calculated averages, geometric means, and any violations.

  • 40 CFR Part 503 governs sludge: ceiling and exceptional-quality pollutant limits, Class A and Class B pathogen reduction, vector attraction reduction, and management practices.

  • The national pretreatment program (40 CFR Part 403) requires industrial users to meet local limits and reporting through a publicly owned treatment works control authority.

  • Bypass, upset, and sanitary sewer overflow events must be reported to the regulatory agency within the time frame stated in the permit, usually by phone followed by written notice.

  • Operator certification is required by state rule; the Class I operator must complete required continuing education hours to renew.

  • Permit limits, monitoring points, and sampling frequencies can only be changed through a formal permit modification, not by plant decision.

Quick reference

Collection Systems and Influent Flow

  • Infiltration is groundwater entering through defective pipe, joints, and manholes; inflow is storm water or drainage entering through direct connections, roof leaders, and manhole covers.

  • Self-cleansing velocity is about 2 ft/s at design flow; velocities above roughly 10 ft/s can scour and damage pipe.

  • Average residential wastewater flow is commonly estimated near 100 gallons per capita per day for dry-weather design.

  • Diurnal peaking factor (peak hourly to average daily flow) is typically 2 to 4, and must be used when sizing pumps, wet wells, and headworks.

  • Slow, septic flow in flat sewers generates hydrogen sulfide, which oxidizes to sulfuric acid and corrodes the concrete crown of the pipe.

  • Lift station wet wells should have enough working volume between pump-on and pump-off to limit motor starts, commonly 6 to 10 starts per hour.

  • Area-velocity flow meters measure both depth and velocity in a pipe; weirs and flumes are used where free-surface measurement is practical.

  • Manholes are placed at changes in pipe size, slope, or direction and at intervals set by state design standards.

Quick reference

Preliminary Treatment (Screening, Grit Removal, Flow Measurement)

  • Grit accumulates at roughly 2 to 12 cubic feet per million gallons treated; screenings average about 0.5 to 2 cubic feet per million gallons.

  • Grit channel velocity is held near 1 ft/s so dense inorganic grit settles while lighter organic solids stay suspended and move on to the clarifiers.

  • A Parshall flume measures depth at one point in the upstream converging section; flow is computed from head, and free flow requires the downstream submergence ratio to stay below about 70%.

  • Weir flow varies with head to the 1.5 power, so small upstream depth errors cause large flow errors; the weir crest must be level and the approach channel quiet.

  • Conversions: 1 MGD = 1.547 cubic feet per second = 694 gallons per minute; 1 cubic foot per second = 0.646 MGD.

  • A rising head differential across a bar screen indicates blinding; the screen is cleaned mechanically or manually before flow backs up into the channel.

  • Aerated grit chambers use air to roll the flow and separate organics from grit; vortex-type units use a gentle spiral with low headloss.

  • Comminutors and grinders shred screenings in the flow stream, reducing handling but returning solids to downstream processes.

Quick reference

Primary Treatment (Sedimentation, Clarifiers)

  • Detention time = basin volume divided by flow; primary clarifiers are normally designed for 1.5 to 2.5 hours at average flow.

  • Surface overflow rate = flow divided by surface area, typically 600 to 1,000 gpd/ft2 at average flow; it sets the settling velocity required for removal.

  • Weir loading rate = effluent flow divided by total weir length, typically 10,000 to 20,000 gpd/ft; high weir loading pulls solids over the weirs.

  • Well-operated primary clarifiers remove about 50 to 65% of influent TSS and 25 to 40% of influent BOD5.

  • Percent removal = [(influent - effluent) / influent] x 100; hydraulic overload shows first as a rising effluent TSS and sludge blanket.

  • Sludge is removed frequently enough to prevent septic conditions; a rising sludge blanket or gas bubbles indicate too long a sludge detention time.

  • Inlet baffles and energy dissipaters prevent short-circuiting; density currents carry flow directly to the weirs and cut actual detention time.

  • Scum is collected at the surface and wasted to digesters, incineration, or landfill; a failing scum trough returns grease to the effluent.

Quick reference

Secondary Treatment (Activated Sludge, Trickling Filters, Ponds)

  • F/M = pounds of BOD5 applied per day divided by pounds of MLVSS under aeration; conventional systems run about 0.2 to 0.4, extended aeration below 0.15.

  • MCRT (sludge age) = pounds of solids in the aeration system divided by pounds of solids leaving per day in waste sludge plus effluent; wasting rate is the main control.

  • Typical mixed liquor suspended solids are 2,000 to 3,000 mg/L and dissolved oxygen in the aeration tank is held near 1.5 to 2.5 mg/L.

  • SVI = 30-minute settled sludge volume (mL/L) x 1,000 / MLSS (mg/L); 80 to 150 is good settling, above about 200 indicates filamentous bulking.

  • RAS is normally 50 to 150% of influent flow; a rising blanket with a low SVI means the return rate should be increased.

  • Trickling filter loading is expressed as lb BOD5 per 1,000 ft3 of media per day and as hydraulic loading in gpd/ft2; sloughing is normal periodic media unloading.

  • Nitrification needs solids retention time above about 8 to 10 days at 20 degrees C, DO above 2 mg/L, and about 7.14 mg of alkalinity per mg of ammonia nitrogen oxidized.

  • Facultative ponds are typically 4 to 8 ft deep with 30 to 180 days detention; algae supply oxygen by day, and bacterial die-off plus sunlight reduce coliforms.

Quick reference

Disinfection and Effluent Quality

  • CT = disinfectant residual (mg/L) x contact time (minutes); colder water, higher pH, and higher ammonia all require a larger CT for the same kill.

  • Chlorine demand = applied dose minus measured residual; demand must be satisfied before any free residual appears.

  • Breakpoint chlorination requires roughly 7.6 mg of chlorine per mg of ammonia nitrogen; past the breakpoint, added chlorine shows up almost entirely as free residual.

  • Dechlorination with sulfur dioxide uses about 1 mg/L of SO2 per 1 mg/L of chlorine residual, adjusted by actual residual testing.

  • Typical fecal coliform limits are a monthly geometric mean near 200 CFU/100 mL with a higher 7-day limit; the actual values are set in the individual permit.

  • UV disinfection is dosed in millijoules per square centimeter, with about 30 mJ/cm2 typical; turbidity, iron, and fouled lamp sleeves shield organisms and reduce dose.

  • Free chlorine is a stronger disinfectant than combined chloramine but dissipates faster and forms disinfection byproducts with organics.

  • Effluent monitoring must use permit-specified methods and frequencies; results are reported as geometric means for bacterial data, never simple arithmetic averages.

Quick reference

Solids Handling, Sludge Treatment, and Disposal

  • Typical solids content: primary sludge 2 to 6%, waste activated sludge 0.5 to 1.5%, gravity-thickened sludge 4 to 6%, dewatered cake 15 to 30%.

  • Anaerobic digesters are usually mesophilic at about 35 degrees C (95 degrees F) with a solids retention time of 15 to 30 days and 40 to 55% volatile solids destruction.

  • Digester stability is judged by the volatile acids to alkalinity ratio: below 0.1 is stable, 0.1 to 0.3 needs watching, and above about 0.35 signals souring.

  • Digester gas is roughly 60 to 65% methane and 30 to 35% carbon dioxide, with about 15 to 18 ft3 of gas produced per pound of volatile solids fed.

  • Percent solids = (dry weight / wet weight) x 100; pounds of solids = concentration in mg/L x volume in MG x 8.34.

  • 40 CFR Part 503 Class B sludge requires fecal coliform below 2,000,000 MPN or CFU per gram of total solids plus a vector attraction reduction option.

  • Gravity thickening is cheapest for waste activated sludge but can turn septic; dissolved air flotation and centrifuges handle light sludges better.

  • Polymer conditioning agglomerates fines so belt presses, filter presses, and centrifuges can capture solids and release free water.

Quick reference

Laboratory Analysis and Process Control Calculations

  • Pounds formula: lb/day = concentration (mg/L) x flow (MGD) x 8.34; use the same formula to convert any dose to pounds.

  • SVI = settled sludge volume in mL/L after 30 minutes x 1,000 / MLSS in mg/L; low SVI means dense, fast-settling sludge.

  • BOD5 is measured at 20 degrees C over 5 days; a nitrification inhibitor gives CBOD5, and seeded dilution water is required when the sample lacks adequate organisms.

  • TSS is determined by filtering a measured sample through a glass fiber filter, drying at 103 to 105 degrees C, and weighing the residue.

  • Volatile solids are the portion lost on ignition at about 550 degrees C, a measure of the organic fraction of sludge or solids.

  • Bacterial results are averaged as a geometric mean (the nth root of the product of n counts) so a single high count does not distort compliance.

  • Percent removal = [(influent - effluent) / influent] x 100; percent volatile solids reduction is calculated between feed and digested sludge.

  • MCRT = total solids in the system divided by solids leaving per day; raising MCRT means wasting less sludge, lowering it means wasting more.

Quick reference

Equipment Maintenance and Support Systems

  • Predictive maintenance uses vibration analysis, thermography, and oil analysis to find bearing wear, imbalance, misalignment, and looseness before failure.

  • Cavitation occurs when suction pressure drops below the liquid vapor pressure; symptoms are noise, vibration, and impeller pitting, corrected by lowering suction lift or clearing blockage.

  • NPSH available must exceed NPSH required by the pump; low NPSH margin is the most common cause of cavitation in suction-lift stations.

  • A properly packed stuffing box should leak a slow, steady drip (roughly 40 to 60 drops per minute) for lubrication and cooling; mechanical seals need clean flush water.

  • Blower and pump capacity drops with a clogged air filter, worn wear rings, or a partially closed valve; check these before assuming motor failure.

  • Preventive maintenance intervals come from the manufacturer's manual and are tracked in a work-order system with equipment history for each asset.

  • All maintenance on pumps, blowers, and mixers requires lockout/tagout; work inside tanks, wet wells, or digesters also requires confined space procedures.

  • Spare parts inventory should cover critical long-lead items such as seals, bearings, check valves, and blower belts to avoid extended bypass or permit violations.