Water Distribution Operator Class I flashcards
Water Distribution Operator Class I · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Specific capacity
- Well pumping rate in gpm divided by drawdown in feet; it indicates well efficiency and declines as the well or aquifer degrades.
- Looped distribution layout
- A grid of interconnected mains that lets water reach any point from two directions, reducing head loss and preventing stagnation.
- 0.433 psi per foot
- Conversion factor stating that each foot of water column exerts 0.433 psi, so 100 feet of elevation creates about 43.3 psi.
- Cone of depression
- The funnel-shaped lowered water table surrounding a pumping well; overlapping cones from nearby wells indicate interference and reduced yield.
- Thrust restraint
- Blocks, rods, or restrained joints that resist the unbalanced force at bends, tees, reducers, and dead ends in pressurized mains.
- Air release valve
- Installed at high points to vent accumulated air that would otherwise reduce capacity and cause erratic flow or water hammer.
- Hazen-Williams C factor
- A roughness coefficient used in the head loss formula; higher values mean smoother pipe and lower values mean older, rougher mains.
- Corporation stop
- A valve installed directly on the water main to connect a service line; it is operated with a special key from the surface.
- Hydrostatic test
- Pressure test of a new main at 1.5 times working pressure, minimum 150 psi, held two hours to check leakage before acceptance.
- AWWA C651
- Standard practice for disinfecting new water mains, typically 50 mg/L chlorine for 24 hours, followed by flushing and coliform sampling.
- Unidirectional flushing
- Flushing in one direction at 2.5 to 5 ft/s with valves sequenced to scour biofilm and sediment from a specific main segment.
- Net positive suction head
- The absolute pressure margin at the pump suction; if available NPSH falls below required NPSH, cavitation damages the impeller.
- Affinity laws
- For a given pump, flow varies with speed, head with speed squared, and power with speed cubed; used to predict speed or impeller changes.
- Altitude valve
- A float-controlled valve at elevated storage that admits water when the tank level drops and closes when the tank is full.
- Pressure zone
- A portion of a distribution system bounded by pressure-reducing valves or booster pumps so pressures stay within 40 to 80 psi.
- CT value
- Disinfectant concentration in mg/L multiplied by contact time in minutes; used to demonstrate inactivation credit for pathogens.
- Nitrification
- Biological oxidation of ammonia to nitrite and nitrate in chloraminated systems, consuming chlorine residual and degrading water quality.
- DPD method
- A colorimetric field test that measures free and total chlorine residual using a reagent that turns pink in proportion to chlorine present.
- Water age
- The average time water resides in the distribution system; high age from oversized mains and dead ends causes residual loss and byproduct formation.
- Air gap
- The only absolute backflow protection: a physical separation between the potable supply outlet and the receptor's flood level.
- Reduced pressure zone
- A testable backflow assembly with two check valves and a relief valve, used for high-hazard connections such as chemical or irrigation lines.
- Backsiphonage
- Backflow caused by negative or reduced pressure in the supply line drawing nonpotable water into the potable system.
- Double check valve assembly
- A testable two-check assembly providing backflow protection for low-hazard cross-connections such as commercial boiler feed or nonchemical connections.
- Permit-required confined space
- A space with limited entry that contains a hazardous atmosphere, engulfment risk, or other serious hazard, requiring an entry permit and attendant.
- Boil water advisory
- A public notice issued when pressure drops below 20 psi or contamination is suspected, telling customers to boil water before drinking.
- Lockout/tagout
- Isolating and locking energy sources, such as electrical disconnects and valves, before maintenance to prevent unexpected startup or release.
- Maximum contaminant level
- The highest allowable concentration of a regulated contaminant in drinking water, enforceable under the Safe Drinking Water Act.
- Lead action level
- The 90th-percentile lead concentration of 0.015 mg/L that triggers corrosion control, public education, and tap sampling requirements.
- Consumer Confidence Report
- An annual water quality report delivered to customers by July 1 that lists detected contaminants, sources, and health effects.
- Detention time
- Volume of a tank or pipe divided by the flow rate through it; units must match, such as gallons divided by gallons per minute.
- Pounds formula
- Pounds per day of chemical equals concentration in mg/L times flow in MGD times 8.34, the weight of one gallon of water.
- Pipe volume factor
- Gallons per foot of pipe equals 0.0408 times the inside diameter in inches squared; used for chlorination and flushing volumes.