Safe yield
The maximum rate at which water can be withdrawn from a source without causing long-term depletion or unacceptable environmental impact.
Watershed
The land area that drains all precipitation to a common outlet, such as a stream, lake, or groundwater recharge area.
Peaking factor
The ratio of maximum demand (day or hour) to average demand, used to size pipes, pumps, and storage.
GWUDI
Groundwater under the direct influence of surface water; requires treatment equivalent to surface water, including filtration and disinfection.
Gate valve
A valve used for isolation, not throttling; it should be fully open or fully closed to prevent seat damage.
Thrust block
A concrete block placed at bends, tees, and dead ends to resist the thrust force created by internal water pressure.
Air release valve
A valve installed at high points of a pipeline to automatically vent trapped air that can restrict flow and cause pressure surges.
Corporation stop
A valve installed at the water main to connect and control flow to an individual service line.
Affinity laws
For a centrifugal pump, flow varies directly with speed, head with the square of speed, and power with the cube of speed.
Cavitation
Formation and collapse of vapor bubbles in a pump due to insufficient NPSHA, causing noise, vibration, and impeller damage.
NPSH
Net positive suction head; NPSHA must exceed NPSHR to prevent cavitation. NPSHA is the absolute pressure available at the pump suction.
Best efficiency point
The flow rate at which a pump operates most efficiently, with minimal vibration and energy use; shown on the pump curve.
Pressure and elevation
Pressure in psi equals elevation in feet multiplied by 0.433; conversely, 1 psi equals 2.31 feet of water column.
Water hammer
A pressure surge caused by a sudden change in flow velocity, often from rapid valve closure, which can damage pipes and fittings.
Altitude valve
A valve that controls the filling of a storage tank by closing when the tank reaches a set maximum water level.
Tank turnover
The time required to replace the volume of water in a storage tank; typically 2–5 days to prevent stagnation and maintain water quality.
CT value
The product of disinfectant concentration (C) and contact time (T), used to determine the effectiveness of disinfection for pathogen inactivation.
Breakpoint chlorination
The point at which chlorine demand is satisfied and further chlorine addition produces free chlorine residual.
Coliform sample
A 100 mL water sample collected in a sterile bottle with sodium thiosulfate, analyzed for total coliform and E. coli bacteria.
Trihalomethanes
Disinfection byproducts formed when chlorine reacts with organic matter; regulated maximum contaminant level is 80 µg/L for TTHM.
Backsiphonage
Backflow caused by negative pressure in the supply line, which can draw non-potable water into the potable system.
Air gap
A physical separation between a potable water outlet and a flood rim, providing the highest level of backflow protection.
RPZ assembly
Reduced pressure zone backflow preventer; a testable assembly used for high-hazard protection that includes two check valves and a relief valve.
Double check valve
A backflow prevention assembly with two check valves, used for low-hazard protection against both backpressure and backsiphonage.
Main disinfection
New water mains are filled with chlorinated water (25–50 mg/L) for 24 hours, flushed, and sampled for bacteria before being placed in service.
Pressure test
A test of a newly installed or repaired pipeline at 1.5 times the working pressure for at least 1.5 hours to check for leaks.
Tapping saddle
A clamp placed around a water main to provide a sealed connection for a service line or branch without shutting down the main.
Valve exercising
The periodic operation of valves to ensure they are functional and can be closed during emergencies; typically done annually.
Confined space
A space with limited entry and exit, not designed for continuous occupancy, requiring atmospheric testing and a permit for entry.
Trench protective system
A method such as sloping, shoring, or a trench box used to protect workers from cave-ins in trenches 5 feet or deeper.
Consumer Confidence Report
An annual water quality report that community water systems must provide to customers by July 1, detailing contaminants and health effects.
SDWA
The Safe Drinking Water Act, the federal law that authorizes EPA to set national drinking water standards and oversee implementation by states.