ABC Class II Water Treatment study materials
ABC Class II Water Treatment study resources

ABC Class II Water Treatment cheat sheet

ABC Class II Water Treatment · Keep the key ideas within reach.

Quick reference

Source Water Characteristics and Protection

  • Turbidity is measured in NTU and indicates suspended particles; higher turbidity increases disinfectant demand and can shield pathogens.

  • TOC indicates organic precursor content; elevated TOC raises disinfection byproduct formation potential after chlorination.

  • Alkalinity buffers pH; water with low alkalinity, often below 50 mg/L as CaCO3, is more sensitive to coagulant acidification.

  • Hardness as CaCO3 reflects calcium and magnesium; high hardness promotes scaling and affects coagulation chemistry.

  • Surface water is vulnerable to Cryptosporidium and Giardia; groundwater under direct influence of surface water requires surface-water-type treatment.

  • A sanitary survey identifies contamination risks in the watershed, wellhead area, treatment plant, storage, and distribution system.

  • Source water pH, temperature, and conductivity affect treatment; temperature changes alter coagulation and disinfection efficiency.

  • Watershed protection uses land-use controls, spill response, and wellhead protection; preventing contamination is preferred over treating it later.

Quick reference

Coagulation, Flocculation, and Sedimentation

  • A jar test determines coagulant dose and pH by comparing settleability and filtered turbidity across several doses.

  • Coagulation destabilizes particles by charge neutralization; flocculation gently mixes water so destabilized particles grow into settleable flocs.

  • Rapid mix velocity gradient is typically 300 to 1000 s^-1 for seconds; flocculation velocity gradient is typically 10 to 75 s^-1 for minutes.

  • Optimum coagulant dose often occurs near charge neutralization; overdosing can restabilize particles and increase residual turbidity.

  • Alkalinity consumes alum or ferric coagulant; insufficient alkalinity depresses pH and may require alkalinity addition.

  • Stokes law settling velocity increases with particle diameter squared and density difference and decreases with water viscosity.

  • Surface overflow rate equals flow divided by basin surface area; particles with settling velocity greater than this rate are ideally removed.

  • Sedimentation performance improves with stable floc, low short-circuiting, and proper sludge removal; excessive weir loading increases solids carryover.

Quick reference

Filtration

  • Filter media effective size and uniformity coefficient describe gradation; uniformity coefficient equals d60 divided by d10.

  • Conventional filtration loading rates are often 2 to 6 gpm/ft2; higher rates increase the risk of particle breakthrough.

  • Backwash expands media and removes captured solids; adequate expansion and duration help prevent mudballs and media loss.

  • Filter headloss increases as media capture particles; terminal headloss triggers backwash before breakthrough occurs.

  • Turbidity breakthrough is passage of particles into filtered water before terminal headloss and is indicated by rising effluent turbidity.

  • Filter ripening is the initial period of higher effluent turbidity after backwash; filter-to-waste or slow starts reduce it.

  • The L/d ratio relates media depth to grain size; deeper beds provide more contact time and solids capacity.

  • Support gravel prevents media loss and distributes backwash water; upset gravel can allow media into the underdrain.

Quick reference

Disinfection and Residual Management

  • CT equals disinfectant residual concentration in mg/L multiplied by contact time in minutes; required CT depends on disinfectant, pH, temperature, and target pathogen.

  • Free chlorine is more effective at lower pH because hypochlorous acid dominates; the pKa is about 7.5 at 25 C.

  • Chlorine demand is the difference between applied dose and residual after contact; demand must be satisfied before a persistent residual remains.

  • Chloramination provides a longer-lasting residual but is a weaker primary disinfectant; it can form nitrite, nitrate, and nitrosamines.

  • UV disinfection inactivates Cryptosporidium but provides no residual; a secondary disinfectant is needed in distribution.

  • Ozone is a strong disinfectant and oxidant; it can produce bromate and requires off-gas ozone destruction.

  • Disinfection byproduct formation increases with TOC, chlorine dose, contact time, pH, and temperature; monitor TTHM and HAA5.

  • Booster chlorination maintains residual in distribution; residual must be monitored at representative distribution points.

  • Dechlorination with reducing agents may be needed before discharging chlorinated water; confirm residual before release.

Quick reference

Chemical Feed, Storage, and Handling

  • Chemical feed rate in lb/day equals flow in MGD multiplied by dose in mg/L multiplied by 8.34.

  • Solution feed rate equals chemical mass dose divided by solution strength; verify units before setting a feed pump.

  • Calibrate chemical feed pumps by measuring delivered volume over time; a drawdown test verifies actual feed rate.

  • Sodium hypochlorite degrades with heat, light, and age; store it cool, dark, ventilated, and rotate stock.

  • Never mix chlorine with ammonia or acids; such reactions can release toxic gas or heat.

  • Secondary containment for liquid chemicals should hold at least the volume of the largest container.

  • Chemical storage areas require ventilation, eyewash access, PPE, and SDS access; incompatible chemicals must be separated.

  • Day tanks should be labeled with chemical name and concentration; feed lines should be dedicated to prevent cross-connections.

Quick reference

Pumps, Valves, Instrumentation, and Maintenance

  • A pump curve plots head versus flow; the operating point is the intersection of the pump curve and system curve.

  • Cavitation occurs when NPSH available is less than NPSH required; it causes noise, vibration, and impeller damage.

  • Affinity laws: flow varies with speed, head with speed squared, and power with speed cubed at constant impeller diameter.

  • Gate valves isolate flow, globe valves regulate flow, check valves prevent backflow, and butterfly valves provide quick isolation.

  • Flow meters require calibration and suitable straight pipe runs; magnetic flow meters need conductive liquid.

  • Preventive maintenance includes lubrication, vibration checks, seal or packing inspection, and valve exercising.

  • Pressure gauges and level sensors must be zeroed or calibrated; inaccurate instruments mislead process control.

  • Lockout/tagout isolates energy before maintenance; verify zero energy and try out the equipment before work.

Quick reference

Laboratory Sampling, Analysis, and Process Control Calculations

  • Sample containers, preservation, and holding times must match the analyte; chlorine and pH are analyzed promptly on site.

  • Chain of custody records sample possession and transfer and preserves regulatory or legal defensibility.

  • Turbidity is measured by nephelometry; calibrate with formazin or approved standards and report results in NTU.

  • The DPD colorimetric method measures free and total chlorine; turbidity and strong oxidants can interfere.

  • Alkalinity titration to pH 4.5 measures total alkalinity and is reported as mg/L CaCO3.

  • Percent removal equals influent concentration minus effluent concentration, divided by influent concentration, times 100.

  • Detention time equals basin volume divided by flow rate; units must be consistent, such as gallons and gallons per minute.

  • Surface loading rate equals flow divided by area and is expressed as gpm/ft2 or m3/m2/d.

  • Log removal equals log10 of influent concentration divided by effluent concentration; 2-log removal is 99 percent and 3-log is 99.9 percent.

Quick reference

Regulations, Records, and Reporting

  • National Primary Drinking Water Regulations set MCLs, MRDLs, treatment techniques, and monitoring requirements.

  • An MCL is the maximum contaminant level allowed in drinking water; an MRDL is the maximum residual disinfectant level; both are enforceable.

  • Public notification Tier 1 is for acute violations and is issued within 24 hours; Tier 2 within 30 days; Tier 3 within 90 days.

  • The Consumer Confidence Report is delivered annually by July 1 and includes source water, detected contaminants, and health effects.

  • Retain monitoring records for at least five years unless a specific rule requires a longer period.

  • The Lead and Copper Rule uses action levels rather than MCLs; an exceedance triggers corrosion control, public education, and replacement requirements.

  • The Disinfection Byproduct Rule sets TTHM and HAA5 MCLs based on locational running annual averages.

  • The Revised Total Coliform Rule uses routine monitoring and assessment or corrective actions when exceedances occur; E. coli has an MCL.

  • Violations must be reported to the primacy agency; falsifying monitoring or reporting records is prohibited.

Quick reference

Safety, Security, and Emergency Response

  • Chlorine gas is heavier than air and irritates the lungs; evacuate upwind and use supplied-air respiratory protection.

  • Confined space entry requires a permit, atmospheric testing for oxygen, flammables, and toxics, an attendant, and a rescue plan.

  • A Safety Data Sheet provides hazard, PPE, first aid, and spill information; keep SDSs accessible to workers.

  • Eyewash and safety shower access should be within 10 seconds travel of corrosive chemical handling areas.

  • Lockout/tagout and zero-energy verification are required before servicing pumps, valves, or electrical equipment.

  • The emergency response plan includes notification, evacuation, spill containment, and mutual aid; conduct practice drills.

  • Security measures include fencing, locked chemical rooms, visitor control, and awareness of chlorine theft or diversion.

  • Electrical safety includes GFCI protection in wet locations, clear panel access, and keeping water away from energized equipment.

Quick reference

Source Water Characteristics and Protection

  • Turbidity is measured in NTU and indicates suspended particles; higher turbidity increases disinfectant demand and can shield pathogens.

  • TOC indicates organic precursor content; elevated TOC raises disinfection byproduct formation potential after chlorination.

  • Alkalinity buffers pH; water with low alkalinity, often below 50 mg/L as CaCO3, is more sensitive to coagulant acidification.

  • Hardness as CaCO3 reflects calcium and magnesium; high hardness promotes scaling and affects coagulation chemistry.

  • Surface water is vulnerable to Cryptosporidium and Giardia; groundwater under direct influence of surface water requires surface-water-type treatment.

  • A sanitary survey identifies contamination risks in the watershed, wellhead area, treatment plant, storage, and distribution system.

  • Source water pH, temperature, and conductivity affect treatment; temperature changes alter coagulation and disinfection efficiency.

  • Watershed protection uses land-use controls, spill response, and wellhead protection; preventing contamination is preferred over treating it later.

Quick reference

Coagulation, Flocculation, and Sedimentation

  • A jar test determines coagulant dose and pH by comparing settleability and filtered turbidity across several doses.

  • Coagulation destabilizes particles by charge neutralization; flocculation gently mixes water so destabilized particles grow into settleable flocs.

  • Rapid mix velocity gradient is typically 300 to 1000 s^-1 for seconds; flocculation velocity gradient is typically 10 to 75 s^-1 for minutes.

  • Optimum coagulant dose often occurs near charge neutralization; overdosing can restabilize particles and increase residual turbidity.

  • Alkalinity consumes alum or ferric coagulant; insufficient alkalinity depresses pH and may require alkalinity addition.

  • Stokes law settling velocity increases with particle diameter squared and density difference and decreases with water viscosity.

  • Surface overflow rate equals flow divided by basin surface area; particles with settling velocity greater than this rate are ideally removed.

  • Sedimentation performance improves with stable floc, low short-circuiting, and proper sludge removal; excessive weir loading increases solids carryover.

Quick reference

Filtration

  • Filter media effective size and uniformity coefficient describe gradation; uniformity coefficient equals d60 divided by d10.

  • Conventional filtration loading rates are often 2 to 6 gpm/ft2; higher rates increase the risk of particle breakthrough.

  • Backwash expands media and removes captured solids; adequate expansion and duration help prevent mudballs and media loss.

  • Filter headloss increases as media capture particles; terminal headloss triggers backwash before breakthrough occurs.

  • Turbidity breakthrough is passage of particles into filtered water before terminal headloss and is indicated by rising effluent turbidity.

  • Filter ripening is the initial period of higher effluent turbidity after backwash; filter-to-waste or slow starts reduce it.

  • The L/d ratio relates media depth to grain size; deeper beds provide more contact time and solids capacity.

  • Support gravel prevents media loss and distributes backwash water; upset gravel can allow media into the underdrain.

Quick reference

Disinfection and Residual Management

  • CT equals disinfectant residual concentration in mg/L multiplied by contact time in minutes; required CT depends on disinfectant, pH, temperature, and target pathogen.

  • Free chlorine is more effective at lower pH because hypochlorous acid dominates; the pKa is about 7.5 at 25 C.

  • Chlorine demand is the difference between applied dose and residual after contact; demand must be satisfied before a persistent residual remains.

  • Chloramination provides a longer-lasting residual but is a weaker primary disinfectant; it can form nitrite, nitrate, and nitrosamines.

  • UV disinfection inactivates Cryptosporidium but provides no residual; a secondary disinfectant is needed in distribution.

  • Ozone is a strong disinfectant and oxidant; it can produce bromate and requires off-gas ozone destruction.

  • Disinfection byproduct formation increases with TOC, chlorine dose, contact time, pH, and temperature; monitor TTHM and HAA5.

  • Booster chlorination maintains residual in distribution; residual must be monitored at representative distribution points.

  • Dechlorination with reducing agents may be needed before discharging chlorinated water; confirm residual before release.

Quick reference

Chemical Feed, Storage, and Handling

  • Chemical feed rate in lb/day equals flow in MGD multiplied by dose in mg/L multiplied by 8.34.

  • Solution feed rate equals chemical mass dose divided by solution strength; verify units before setting a feed pump.

  • Calibrate chemical feed pumps by measuring delivered volume over time; a drawdown test verifies actual feed rate.

  • Sodium hypochlorite degrades with heat, light, and age; store it cool, dark, ventilated, and rotate stock.

  • Never mix chlorine with ammonia or acids; such reactions can release toxic gas or heat.

  • Secondary containment for liquid chemicals should hold at least the volume of the largest container.

  • Chemical storage areas require ventilation, eyewash access, PPE, and SDS access; incompatible chemicals must be separated.

  • Day tanks should be labeled with chemical name and concentration; feed lines should be dedicated to prevent cross-connections.

Quick reference

Pumps, Valves, Instrumentation, and Maintenance

  • A pump curve plots head versus flow; the operating point is the intersection of the pump curve and system curve.

  • Cavitation occurs when NPSH available is less than NPSH required; it causes noise, vibration, and impeller damage.

  • Affinity laws: flow varies with speed, head with speed squared, and power with speed cubed at constant impeller diameter.

  • Gate valves isolate flow, globe valves regulate flow, check valves prevent backflow, and butterfly valves provide quick isolation.

  • Flow meters require calibration and suitable straight pipe runs; magnetic flow meters need conductive liquid.

  • Preventive maintenance includes lubrication, vibration checks, seal or packing inspection, and valve exercising.

  • Pressure gauges and level sensors must be zeroed or calibrated; inaccurate instruments mislead process control.

  • Lockout/tagout isolates energy before maintenance; verify zero energy and try out the equipment before work.

Quick reference

Laboratory Sampling, Analysis, and Process Control Calculations

  • Sample containers, preservation, and holding times must match the analyte; chlorine and pH are analyzed promptly on site.

  • Chain of custody records sample possession and transfer and preserves regulatory or legal defensibility.

  • Turbidity is measured by nephelometry; calibrate with formazin or approved standards and report results in NTU.

  • The DPD colorimetric method measures free and total chlorine; turbidity and strong oxidants can interfere.

  • Alkalinity titration to pH 4.5 measures total alkalinity and is reported as mg/L CaCO3.

  • Percent removal equals influent concentration minus effluent concentration, divided by influent concentration, times 100.

  • Detention time equals basin volume divided by flow rate; units must be consistent, such as gallons and gallons per minute.

  • Surface loading rate equals flow divided by area and is expressed as gpm/ft2 or m3/m2/d.

  • Log removal equals log10 of influent concentration divided by effluent concentration; 2-log removal is 99 percent and 3-log is 99.9 percent.

Quick reference

Regulations, Records, and Reporting

  • National Primary Drinking Water Regulations set MCLs, MRDLs, treatment techniques, and monitoring requirements.

  • An MCL is the maximum contaminant level allowed in drinking water; an MRDL is the maximum residual disinfectant level; both are enforceable.

  • Public notification Tier 1 is for acute violations and is issued within 24 hours; Tier 2 within 30 days; Tier 3 within 90 days.

  • The Consumer Confidence Report is delivered annually by July 1 and includes source water, detected contaminants, and health effects.

  • Retain monitoring records for at least five years unless a specific rule requires a longer period.

  • The Lead and Copper Rule uses action levels rather than MCLs; an exceedance triggers corrosion control, public education, and replacement requirements.

  • The Disinfection Byproduct Rule sets TTHM and HAA5 MCLs based on locational running annual averages.

  • The Revised Total Coliform Rule uses routine monitoring and assessment or corrective actions when exceedances occur; E. coli has an MCL.

  • Violations must be reported to the primacy agency; falsifying monitoring or reporting records is prohibited.

Quick reference

Safety, Security, and Emergency Response

  • Chlorine gas is heavier than air and irritates the lungs; evacuate upwind and use supplied-air respiratory protection.

  • Confined space entry requires a permit, atmospheric testing for oxygen, flammables, and toxics, an attendant, and a rescue plan.

  • A Safety Data Sheet provides hazard, PPE, first aid, and spill information; keep SDSs accessible to workers.

  • Eyewash and safety shower access should be within 10 seconds travel of corrosive chemical handling areas.

  • Lockout/tagout and zero-energy verification are required before servicing pumps, valves, or electrical equipment.

  • The emergency response plan includes notification, evacuation, spill containment, and mutual aid; conduct practice drills.

  • Security measures include fencing, locked chemical rooms, visitor control, and awareness of chlorine theft or diversion.

  • Electrical safety includes GFCI protection in wet locations, clear panel access, and keeping water away from energized equipment.