ABDSM study materials
ABDSM study resources

ABDSM cheat sheet

ABDSM · Keep the key ideas within reach.

Quick reference

Patient Selection and Clinical Evaluation

  • STOP-BANG: 3 or more positive items indicates high OSA risk; scores 5 or more indicate high perioperative risk.

  • Berlin Questionnaire screens via 3 categories: snoring/witnessed apnea, daytime sleepiness, and hypertension/BMI; 2 or more positive categories = high risk.

  • Epworth Sleepiness Scale: 0-10 normal, 11-12 mild, 13-15 moderate, 16-24 severe excessive daytime sleepiness.

  • Excessive daytime sleepiness plus high-risk screen warrants referral for diagnostic sleep testing before appliance therapy.

  • Mandibular advancement is contraindicated in insufficient periodontal support, active caries, and inadequate tooth count for retention.

  • Minimum retention typically requires 6-8 teeth per arch with healthy periodontium; fewer teeth may still allow therapy with careful design.

  • Temporomandibular disorder symptoms (joint noise, pain, limited opening) require evaluation and documented baseline before appliance therapy.

  • Nasal obstruction reduces CPAP tolerance and can limit oral appliance effectiveness; evaluate patency and refer when indicated.

  • Body mass index, neck circumference, and Mallampati score are predictors of OSA severity and influence treatment selection.

Quick reference

Sleep-Related Breathing Disorders and Diagnosis

  • Apnea: 90% or greater airflow reduction for at least 10 seconds; hypopnea: 30% or greater reduction with 3% or greater desaturation or an arousal.

  • AHI = total apneas plus hypopneas divided by total sleep time in hours; AHI 5-15 mild, 15-30 moderate, greater than 30 severe.

  • OSA diagnosis requires AHI 5 or greater with symptoms, or AHI 15 or greater regardless of symptoms.

  • Central apnea: absent airflow with absent respiratory effort; obstructive apnea: absent airflow with continued effort.

  • Oxygen desaturation index (ODI) counts desaturation events per hour and correlates with AHI but is not diagnostic alone.

  • Home sleep apnea test is valid for suspected moderate-to-severe OSA in adults without major cardiopulmonary comorbidity.

  • In-lab polysomnography is indicated for suspected central apnea, comorbid heart failure, severe COPD, or non-diagnostic home testing.

  • RERA: increasing respiratory effort leading to arousal without meeting apnea or hypopnea criteria; contributes to UARS.

  • Supine AHI can be markedly higher than non-supine AHI; positional OSA affects appliance and treatment planning.

Quick reference

Oral Appliance Therapy: Devices, Design, and Fabrication

  • Mandibular advancement device (MAD) protrudes the mandible to enlarge the pharyngeal airway; tongue-retaining devices (TRD) hold the tongue forward.

  • MADs are first-line for mild-to-moderate OSA and for CPAP-intolerant patients with moderate-to-severe OSA.

  • Effective protrusion is typically 50-70% of maximum mandibular protrusion; titration begins at 60-70% of that target.

  • Vertical opening should be minimized to reduce posterior mandibular rotation and airway narrowing while allowing adequate coupling.

  • Bite registration records maximum protrusion and vertical dimension; a George Gauge or equivalent records protrusive position.

  • Bilateral balanced contacts in the registration position reduce occlusal loading and prevent unintended tooth movement.

  • Custom titratable devices outperform non-titratable or thermoplastic devices in efficacy and adherence.

  • Appliance material choice (hard acrylic, dual laminate, flexible) affects durability, retention, and occlusal wear.

  • Post-insertion occlusal changes include reduced overjet and overbite; baseline cephalometric or occlusal records document change.

Quick reference

Titration, Follow-Up, and Treatment Adherence

  • Titration advances the mandible in small increments (typically 0.25-0.5 mm per step) over weeks until symptoms resolve or efficacy is confirmed.

  • Objective efficacy is confirmed by follow-up sleep testing showing AHI reduction, often defined as AHI less than 5 or a 50% or greater reduction.

  • Initial follow-up occurs within 1-4 weeks of delivery to check comfort, retention, and tissue response.

  • Adherence is assessed by patient report, device wear time, and symptom control; MAD adherence is often defined as 4 or more nights per week.

  • Common side effects include salivation, dry mouth, tooth discomfort, and morning jaw soreness; most resolve within weeks.

  • Persistent pain, bite change, or TMJ symptoms warrant reducing advancement or revising the appliance.

  • Periodic reassessment (at least annually) monitors occlusal changes, appliance integrity, and continued efficacy.

  • Combination therapy with CPAP or positional therapy may be needed when MAD alone does not achieve target AHI.

Quick reference

Dentistry and Dental Sleep Medicine

  • Baseline dental records for appliance therapy include periodontal charting, caries assessment, occlusion, and TMJ evaluation.

  • Informed consent documents risks of occlusal change, tooth movement, TMJ symptoms, and the need for ongoing monitoring.

  • Adequate salivary flow and periodontal health support appliance tolerance; xerostomia increases caries and retention problems.

  • Appliance hygiene: daily cleaning and periodic professional evaluation reduce microbial load and tissue irritation.

  • Occlusal changes from long-term MAD use include mesial drift, reduced overjet/overbite, and anterior open bite tendencies.

  • Screening for dental contraindications includes unrestored caries, advanced periodontal disease, and inadequate abutment teeth.

  • Bruxism may increase appliance wear and fracture risk; night guards are not substitutes for advancement devices.

  • Record keeping includes photographs, mounted casts or digital scans, and bite registration to document baseline and change.

Quick reference

Interprofessional Collaboration and Practice Management

  • Dental sleep medicine practice requires physician diagnosis of OSA; dentists screen and treat but do not diagnose.

  • Collaboration model: physician orders sleep testing and diagnosis, dentist fabricates and titrates the appliance, physician reviews efficacy.

  • Objective follow-up testing after appliance titration confirms efficacy and supports documentation for the medical record.

  • Reimbursement often requires a physician diagnosis, documented AHI, and evidence of CPAP intolerance or patient preference.

  • Scope of practice varies by jurisdiction; dentists must confirm local regulations before providing appliance therapy.

  • Communication with the sleep physician includes appliance type, advancement achieved, and follow-up test results.

  • Documentation should include screening results, referral, diagnosis, device design, titration record, and adherence notes.

  • Patient education covers device use, cleaning, expected side effects, and the need for periodic reassessment.

Quick reference

Patient Selection and Clinical Evaluation

  • STOP-BANG: 3 or more positive items indicates high OSA risk; scores 5 or more indicate high perioperative risk.

  • Berlin Questionnaire screens via 3 categories: snoring/witnessed apnea, daytime sleepiness, and hypertension/BMI; 2 or more positive categories = high risk.

  • Epworth Sleepiness Scale: 0-10 normal, 11-12 mild, 13-15 moderate, 16-24 severe excessive daytime sleepiness.

  • Excessive daytime sleepiness plus high-risk screen warrants referral for diagnostic sleep testing before appliance therapy.

  • Mandibular advancement is contraindicated in insufficient periodontal support, active caries, and inadequate tooth count for retention.

  • Minimum retention typically requires 6-8 teeth per arch with healthy periodontium; fewer teeth may still allow therapy with careful design.

  • Temporomandibular disorder symptoms (joint noise, pain, limited opening) require evaluation and documented baseline before appliance therapy.

  • Nasal obstruction reduces CPAP tolerance and can limit oral appliance effectiveness; evaluate patency and refer when indicated.

  • Body mass index, neck circumference, and Mallampati score are predictors of OSA severity and influence treatment selection.

Quick reference

Sleep-Related Breathing Disorders and Diagnosis

  • Apnea: 90% or greater airflow reduction for at least 10 seconds; hypopnea: 30% or greater reduction with 3% or greater desaturation or an arousal.

  • AHI = total apneas plus hypopneas divided by total sleep time in hours; AHI 5-15 mild, 15-30 moderate, greater than 30 severe.

  • OSA diagnosis requires AHI 5 or greater with symptoms, or AHI 15 or greater regardless of symptoms.

  • Central apnea: absent airflow with absent respiratory effort; obstructive apnea: absent airflow with continued effort.

  • Oxygen desaturation index (ODI) counts desaturation events per hour and correlates with AHI but is not diagnostic alone.

  • Home sleep apnea test is valid for suspected moderate-to-severe OSA in adults without major cardiopulmonary comorbidity.

  • In-lab polysomnography is indicated for suspected central apnea, comorbid heart failure, severe COPD, or non-diagnostic home testing.

  • RERA: increasing respiratory effort leading to arousal without meeting apnea or hypopnea criteria; contributes to UARS.

  • Supine AHI can be markedly higher than non-supine AHI; positional OSA affects appliance and treatment planning.

Quick reference

Oral Appliance Therapy: Devices, Design, and Fabrication

  • Mandibular advancement device (MAD) protrudes the mandible to enlarge the pharyngeal airway; tongue-retaining devices (TRD) hold the tongue forward.

  • MADs are first-line for mild-to-moderate OSA and for CPAP-intolerant patients with moderate-to-severe OSA.

  • Effective protrusion is typically 50-70% of maximum mandibular protrusion; titration begins at 60-70% of that target.

  • Vertical opening should be minimized to reduce posterior mandibular rotation and airway narrowing while allowing adequate coupling.

  • Bite registration records maximum protrusion and vertical dimension; a George Gauge or equivalent records protrusive position.

  • Bilateral balanced contacts in the registration position reduce occlusal loading and prevent unintended tooth movement.

  • Custom titratable devices outperform non-titratable or thermoplastic devices in efficacy and adherence.

  • Appliance material choice (hard acrylic, dual laminate, flexible) affects durability, retention, and occlusal wear.

  • Post-insertion occlusal changes include reduced overjet and overbite; baseline cephalometric or occlusal records document change.

Quick reference

Titration, Follow-Up, and Treatment Adherence

  • Titration advances the mandible in small increments (typically 0.25-0.5 mm per step) over weeks until symptoms resolve or efficacy is confirmed.

  • Objective efficacy is confirmed by follow-up sleep testing showing AHI reduction, often defined as AHI less than 5 or a 50% or greater reduction.

  • Initial follow-up occurs within 1-4 weeks of delivery to check comfort, retention, and tissue response.

  • Adherence is assessed by patient report, device wear time, and symptom control; MAD adherence is often defined as 4 or more nights per week.

  • Common side effects include salivation, dry mouth, tooth discomfort, and morning jaw soreness; most resolve within weeks.

  • Persistent pain, bite change, or TMJ symptoms warrant reducing advancement or revising the appliance.

  • Periodic reassessment (at least annually) monitors occlusal changes, appliance integrity, and continued efficacy.

  • Combination therapy with CPAP or positional therapy may be needed when MAD alone does not achieve target AHI.

Quick reference

Dentistry and Dental Sleep Medicine

  • Baseline dental records for appliance therapy include periodontal charting, caries assessment, occlusion, and TMJ evaluation.

  • Informed consent documents risks of occlusal change, tooth movement, TMJ symptoms, and the need for ongoing monitoring.

  • Adequate salivary flow and periodontal health support appliance tolerance; xerostomia increases caries and retention problems.

  • Appliance hygiene: daily cleaning and periodic professional evaluation reduce microbial load and tissue irritation.

  • Occlusal changes from long-term MAD use include mesial drift, reduced overjet/overbite, and anterior open bite tendencies.

  • Screening for dental contraindications includes unrestored caries, advanced periodontal disease, and inadequate abutment teeth.

  • Bruxism may increase appliance wear and fracture risk; night guards are not substitutes for advancement devices.

  • Record keeping includes photographs, mounted casts or digital scans, and bite registration to document baseline and change.

Quick reference

Interprofessional Collaboration and Practice Management

  • Dental sleep medicine practice requires physician diagnosis of OSA; dentists screen and treat but do not diagnose.

  • Collaboration model: physician orders sleep testing and diagnosis, dentist fabricates and titrates the appliance, physician reviews efficacy.

  • Objective follow-up testing after appliance titration confirms efficacy and supports documentation for the medical record.

  • Reimbursement often requires a physician diagnosis, documented AHI, and evidence of CPAP intolerance or patient preference.

  • Scope of practice varies by jurisdiction; dentists must confirm local regulations before providing appliance therapy.

  • Communication with the sleep physician includes appliance type, advancement achieved, and follow-up test results.

  • Documentation should include screening results, referral, diagnosis, device design, titration record, and adherence notes.

  • Patient education covers device use, cleaning, expected side effects, and the need for periodic reassessment.