ABMP Medical Health Physics study materials
ABMP Medical Health Physics study resources

ABMP Medical Health Physics flashcards

ABMP Medical Health Physics · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Half-life
Time required for the activity of a radionuclide to decrease to half its initial value; T½ = ln2/λ, where λ is the decay constant.
Becquerel
SI unit of radioactivity equal to one disintegration per second; 1 Ci = 3.7×10^10 Bq.
Photoelectric effect
Photon interaction in which the photon transfers all its energy to an inner-shell electron, which is ejected; dominant at low energies and high atomic number.
Geiger-Mueller counter
Gas-filled detector operating in the Geiger region; highly sensitive but cannot discriminate photon energy and has significant dead time.
Ionization chamber
Gas-filled detector operating in the ionization region; used as the reference instrument for radiation protection surveys and dose rate measurements.
HPGe detector
High-purity germanium semiconductor detector providing excellent energy resolution for gamma spectroscopy; requires cryogenic cooling.
Absorbed dose
Energy deposited by ionizing radiation per unit mass of material; SI unit is the gray (Gy), equal to 1 J/kg.
Equivalent dose
Absorbed dose averaged over a tissue or organ multiplied by the radiation weighting factor w_R; SI unit is the sievert (Sv).
Effective dose
Sum over tissues of equivalent dose multiplied by tissue weighting factor w_T; used to estimate stochastic risk; unit is the sievert.
Kerma
Kinetic energy released per unit mass in a medium by indirectly ionizing radiation; air kerma is the basis of many calibration protocols.
Stochastic effect
Radiation effect, such as cancer, for which probability increases with dose and for which no threshold is assumed.
Deterministic effect
Tissue reaction that has a threshold dose and whose severity increases with dose, such as erythema or cataracts.
Linear-quadratic model
Cell survival model S = e^(−αD−βD²); α/β ratio distinguishes early-responding (~10 Gy) from late-responding (~3 Gy) tissues.
ALARA
Principle of keeping radiation doses as low as reasonably achievable, considering economic and social factors, through time, distance, and shielding.
Dose limit
Regulatory upper bound on dose to workers or the public; ICRP occupational limit is 20 mSv/y averaged over 5 years.
Medical event
Administration of byproduct material differing from the prescribed dose by 20% or more and exceeding 0.5 Sv to an organ or 50 mSv effective dose.
Bremsstrahlung
Continuous X-ray spectrum produced when electrons decelerate in the anode target; maximum photon energy equals the applied kVp.
Half-value layer
Thickness of material that reduces photon intensity to half its original value; HVL = ln2/μ, typically 2.5–4 mm Al in diagnostic beams.
CTDIvol
Volume computed tomography dose index, a standardized measure of CT radiation output per unit volume; DLP equals CTDIvol times scan length.
Tc-99m
Technetium-99m, a 6-hour half-life radionuclide emitting 140 keV gamma rays; the most widely used diagnostic radiopharmaceutical.
PET annihilation
Positron emission tomography process in which a positron annihilates with an electron, producing two 511 keV photons emitted approximately 180 degrees apart.
Dose calibrator
Re-entrant ionization chamber used to measure the activity of radiopharmaceuticals before administration; geometry and volume affect readings.
Percentage depth dose
Ratio of absorbed dose at a given depth to the maximum dose along the central axis of a radiation beam, expressed as a percentage.
Brachytherapy TG-43
Dosimetry formalism for brachytherapy sources that calculates dose to water using radial dose and anisotropy functions.
Primary barrier
Shielding designed to attenuate the primary radiation beam; its thickness depends on workload, use factor, occupancy, and distance.
Occupancy factor
Factor T used in shielding calculations reflecting the fraction of time an area is occupied; full 1, partial 1/4, occasional 1/16.
Tenth-value layer
Thickness of material that reduces photon intensity to one tenth; number of TVLs equals log10 of the inverse transmission.
Personal dosimeter
Device such as a TLD, OSL, or film badge worn to measure occupational dose; ring badges measure extremity dose.
Investigation level
Dose threshold, typically 10%, 30%, or 100% of the regulatory limit, that triggers review, investigation, or reporting.
Public dose limit
Regulatory limit on dose to members of the public from licensed activities, generally 1 mSv per year.
Secular equilibrium
Condition in a decay chain where the parent half-life greatly exceeds the daughter half-life, so daughter activity approaches parent activity.
Radiation weighting factor
Factor w_R that adjusts absorbed dose for the biological effectiveness of the radiation type; 1 for photons, 20 for alpha particles.