ABPros Prosthodontics study materials
ABPros Prosthodontics study resources

ABPros Prosthodontics cheat sheet

ABPros Prosthodontics · Keep the key ideas within reach.

Quick reference

Section A: Diagnosis, Treatment Planning, and Prognosis

  • Prognosis is assigned per tooth, not per arch: factors include mobility, furcation involvement, crown-to-root ratio, residual bone support, and endodontic status.

  • A crown-to-root ratio of 1:1 is generally the minimum acceptable for a tooth intended as a fixed partial denture abutment; 2:1 or worse is a guarded-to-poor prognosis.

  • Ante's law: the total pericemental area of the abutment roots must equal or exceed that of the teeth being replaced; a tapered premolar abutment adjacent to a molar span frequently violates it.

  • Furcation involvement is classified I-IV (Glickman) or by horizontal/vertical bone loss (Hamp); Class III-IV furcations carry a guarded prognosis and are relative contraindications to FPD abutment use.

  • Mobility is graded 0-3 (Miller); Grade 3 (greater than 1 mm buccolingual plus vertical depression) signals loss of attachment insufficient for a load-bearing abutment.

  • A tooth with a questionable prognosis should be extracted before, not after, fabrication of an adjacent prosthesis, because later loss compromises the span design.

  • Diagnostic casts mounted in a semi-adjustable articulator with a facebow permit evaluation of occlusal plane, curve of Spee, and interocclusal space before committing to a design.

  • Vertical dimension of occlusion is assessed at rest minus freeway space (typically 2-4 mm anteriorly); arbitrary alteration without cephalometric or phonetic support risks phonetic and esthetic failure.

Quick reference

Section B: Fixed Prosthodontics

  • Finish line selection: chamfer (0.3-0.5 mm) for metal and metal-ceramic margins, shoulder or deep chamfer (1.0-1.2 mm) for all-ceramic, knife-edge is contraindicated for any cast or ceramic restoration.

  • Axial reduction for metal-ceramic is approximately 1.0-1.5 mm; for zirconia and lithium disilicate, 1.0-1.5 mm axial and 1.5-2.0 mm occlusal to resist flexure.

  • Taper (total occlusal convergence) for a single cast crown should be 10-20 degrees; excessive taper reduces retention, insufficient taper prevents seating.

  • Retention and resistance form: resistance requires a preparation height-to-width ratio of at least 0.4; short crowns need grooves, boxes, or pins to supplement.

  • Marginal fit standard: clinically acceptable cast or milled margins are typically within 25-40 micrometers; ceramic margins should be evaluated with an explorer and radiograph at interproximal seats.

  • Pontic design: modified ridge lap for esthetic anterior spans, sanitary or ovate for posterior; ovate pontics require a soft-tissue socket and 2-3 mm of tissue depth.

  • Connector cross-sectional area minimums: about 9 mm squared for metal-ceramic posterior, 12-16 mm squared for zirconia posterior to resist fracture.

  • Occlusal contacts on a single crown are adjusted in maximum intercuspation and excursive movements before cementation; heavy centric contacts cause fracture and pulpal symptoms.

Quick reference

Section C: Removable Prosthodontics

  • Complete denture support derives from the residual ridge; stability resists horizontal forces; retention resists vertical dislodging forces.

  • Border molding captures the functional sulcus; the denture border should extend into the vestibule to the mucogingival junction and be 2-3 mm short of the vibrating line posteriorly.

  • Posterior palatal seal provides retention via a valve seal at the junction of the hard and soft palate, terminating at the fovea palatini or slightly anterior.

  • Balanced occlusion in complete dentures requires bilateral simultaneous contacts in centric and eccentric positions; nonbalanced contacts cause tipping and soreness.

  • Neutral zone: the space where forces from tongue, lips, and cheeks are in equilibrium; teeth placed in this zone improve stability and patient tolerance.

  • Abutment selection for RPD: only teeth with adequate crown-root ratio and periodontal support; a lone distal abutment with no cross-arch stabilization is a guarded design.

  • Major connector design: maxillary palatal plate or bar, mandibular lingual bar (requires 4 mm of lingual height) or lingual plate when height is insufficient; borders must be 3-4 mm from the gingival margin.

  • RPD clasps: circumferential (Akens) for bounded saddles and molar retention, bar (Roach) for tissue-ward approach on premolars; reciprocal arms must oppose the retentive arm.

Quick reference

Section D: Implant, Occlusion, and Materials

  • Implant survival is enhanced by primary stability and a minimum insertion torque; immediately loaded implants generally require torque above 30-35 Ncm and adequate bone density (Type II-III).

  • Minimum inter-implant distance is 3 mm between adjacent implants; minimum implant-to-tooth distance is 1.5 mm to preserve the interimplant papilla and crestal bone.

  • Bone density classification (Lekholm and Zarb / Misch): Type I dense cortical to Type IV low-density trabecular; Type IV sites show lower primary stability and require undersized drilling or delayed loading.

  • Occlusal scheme for implants: flat, shallow cusp inclines, narrower occlusal tables, and no working-side contacts in lateral excursion reduce off-axis load and screw loosening.

  • Ceramic strength hierarchy for clinical use: zirconia (about 900-1200 MPa flexural) greater than lithium disilicate (about 360-450 MPa) greater than leucite-reinforced glass (about 100-160 MPa) greater than feldspathic (about 60-100 MPa).

  • Resin cement is indicated for etched glass-ceramic and for implant-supported restorations where retrievability is desired; zinc phosphate and glass ionomer are not indicated for bonded ceramic.

  • Implant success criteria (Buser/Albrektsson): less than 0.2 mm annual bone loss after the first year, no mobility, no pain or neuropathy, and no peri-implant radiolucency.

  • Screw-retained versus cement-retained: screw retention favors retrievability and posterior or multi-unit cases; cement retention favors esthetics and divergent angulation but carries retained cement risk.