- Photoelectric effect
- Related: Compton scatter, K-edge, Mass attenuation coefficient
Interaction in which an incident photon transfers its entire energy to an inner-shell electron, ejecting it; probability rises sharply with atomic number and falls rapidly as photon energy increases, producing high subject contrast.
- Compton scatter
- Related: Photoelectric effect, Scatter-to-primary ratio, Linear attenuation coefficient
Interaction in which a photon transfers part of its energy to an outer-shell electron and is deflected; probability depends on electron density and is nearly independent of atomic number, degrading contrast and creating occupational dose.
- K-edge
- Related: Photoelectric effect, Contrast agent
Sudden increase in attenuation at the photon energy just above the binding energy of a shell's electrons, named for the K shell; exploited by iodine and barium to boost contrast at diagnostic energies.
- Linear attenuation coefficient
- Related: Mass attenuation coefficient, Half-value layer
Probability per unit path length that a photon interacts while traveling through material; depends on photon energy and material density, and is the basis for exponential attenuation of a beam.
- Half-value layer
- Related: Linear attenuation coefficient, Beam hardening
Thickness of a specified material that reduces the intensity of a beam to half its original value; used to characterize beam quality and required filtration in radiography.
- Beam hardening
- Related: Half-value layer, Hounsfield unit
Progressive shift of a polyenergetic x-ray beam toward higher average energy as low-energy photons are preferentially absorbed in tissue; causes cupping and streak artifacts in CT.
- Hounsfield unit
- Related: Beam hardening, Window width and level
Scaled CT attenuation value defined so that water is 0 and air is approximately -1000; each unit represents about 0.1 percent difference in attenuation from water.
- Window width and level
- Related: Hounsfield unit
Display settings that map the CT attenuation range to visible gray shades; level sets the center of the range and width sets its span, controlling contrast and brightness on the monitor.
- Modulation transfer function
- Related: Detective quantum efficiency, Aliasing
Curve describing how well an imaging system preserves the contrast of structures at each spatial frequency; it quantifies spatial resolution and falls toward zero at the limiting frequency.
- Detective quantum efficiency
- Related: Modulation transfer function, Quantum mottle
Ratio of the squared signal-to-noise ratio at the detector output to that at its input, expressed as a percentage; a combined measure of a detector's dose efficiency and image quality.
- Quantum mottle
- Related: Detective quantum efficiency, Signal-to-noise ratio
Speckled noise in an image caused by statistical fluctuation in the number of detected photons; becomes prominent when too few photons reach the detector and is reduced by increasing dose or pixel area.
- Aliasing
- Related: Modulation transfer function
Artifact in which spatial frequencies above the sampling limit are misrepresented as lower frequencies; prevented by adequate sampling or by filtering before digitization.
- T1 relaxation
- Related: T2 relaxation, Repetition time
Time constant describing recovery of longitudinal magnetization after an radiofrequency pulse; differs among tissues and is the primary contrast source in spin-echo and inversion-recovery imaging.
- T2 relaxation
- Related: T1 relaxation, Gradient echo
Time constant describing decay of transverse magnetization from spin-spin dephasing after an radiofrequency pulse; short in solids and long in fluids such as cerebrospinal fluid.
- Gradient echo
- Related: T2 relaxation, Echo time
Pulse sequence that refocuses transverse magnetization by reversing a magnetic field gradient rather than using a 180-degree pulse; allows short repetition times and is sensitive to field inhomogeneity, producing T2-star weighting.
- Specific absorption rate
- Related: T1 relaxation
Radiofrequency energy deposited per unit mass of tissue per unit time, usually in watts per kilogram; regulatory limits constrain SAR to prevent heating during MRI.
- Echo time
- Related: Repetition time, Gradient echo
Interval between the radiofrequency excitation pulse and the center of the acquired echo; controls the degree of T1 or T2 weighting in MRI.
- Repetition time
- Related: Echo time, T1 relaxation
Interval between successive radiofrequency excitation pulses in a pulse sequence; determines how much longitudinal magnetization recovers before the next pulse and influences T1 weighting and scan time.
- Linear energy transfer
- Related: Relative biological effectiveness, Oxygen enhancement ratio
Average energy deposited per unit path length by ionizing radiation; high-LET radiations such as alpha particles and neutrons cause dense ionization and greater biological damage per unit dose.
- Relative biological effectiveness
- Related: Linear energy transfer, Equivalent dose
Ratio of a reference radiation dose to the test radiation dose producing the same biological effect; increases with linear energy transfer and is used to derive equivalent dose.
- Oxygen enhancement ratio
- Related: Linear energy transfer, Relative biological effectiveness
Ratio of dose required to produce a given effect under hypoxic versus well-oxygenated conditions; typically about three for low-LET radiation and near one for high-LET radiation.
- Equivalent dose
- Related: Effective dose, Relative biological effectiveness
Dose quantity obtained by multiplying absorbed dose by a radiation weighting factor to account for biological effectiveness; expressed in sieverts and used for radiation protection purposes.
- Effective dose
- Related: Equivalent dose, Collective effective dose
Sum of tissue-weighted equivalent doses across organs, reflecting overall stochastic risk from a nonuniform exposure; expressed in sieverts and used to compare imaging procedures.
- Alpha/beta ratio
- Related: Linear-quadratic model, Biologically effective dose
Dose at which linear and quadratic components of cell killing are equal in the linear-quadratic model; low values indicate strong fractionation sensitivity, typical of late-responding tissues and prostate cancer.
- Biologically effective dose
- Related: Alpha/beta ratio, Linear-quadratic model
Dose metric derived from the linear-quadratic model that accounts for fraction size and number, allowing comparison of regimens with different fractionation; expressed in gray equivalents.
- Linear-quadratic model
- Related: Alpha/beta ratio, Biologically effective dose
Mathematical model in which cell survival after radiation is described by a linear and a quadratic term in dose; predicts survival for different fractionation schemes and underlies biologically effective dose calculations.
- Law of Bergonie and Tribondeau
- Related: Linear energy transfer, Tumor control probability
Principle stating that cells are most radiosensitive when they are rapidly dividing, undifferentiated, and have a long proliferative future; explains sensitivity patterns of tissues and tumors.
- Tumor control probability
- Related: Normal tissue complication probability, Law of Bergonie and Tribondeau
Probability that a tumor is eradicated by a given radiation dose; rises sigmoidally with dose and depends on tumor cell number and intrinsic radiosensitivity.
- Normal tissue complication probability
- Related: Tumor control probability, Alpha/beta ratio
Modeled probability that a specified normal tissue develops a defined complication after a given dose distribution; used to compare treatment plans and set dose constraints.
- Collective effective dose
- Related: Effective dose, ALARA
Sum of effective doses to all exposed individuals in a population, expressed in person-sieverts; used to estimate population-level stochastic risk from a practice or event.
- ALARA
- Related: Collective effective dose, Justification
Principle of keeping radiation doses as low as reasonably achievable, considering economic and social factors; applied through time, distance, and shielding in occupational and patient protection.
- Justification
- Related: ALARA, Diagnostic reference level
Core radiation protection principle requiring that a proposed exposure produce more benefit than harm; for medical imaging, that the examination is appropriate for the clinical question.
- Diagnostic reference level
- Related: Justification, Collective effective dose
Benchmark dose or activity for a given examination and patient group, usually set near the upper quartile of observed values; used to identify practices with unusually high exposure.
- Informed consent
- Related: Justification
Process of disclosing material risks, benefits, and alternatives to a patient and confirming voluntary agreement before a procedure; required for contrast administration and invasive interventions per local policy.
- Contrast-induced nephropathy
- Related: Informed consent
Acute kidney injury occurring after intravascular iodinated contrast administration, attributed to the contrast after other causes are excluded; risk is highest with preexisting renal impairment, diabetes, and dehydration.
- Gadolinium deposition
- Related: Informed consent
Retention of small amounts of gadolinium in tissues such as brain and bone after administration of linear agents; motivates preferential use of macrocyclic agents and avoidance of unnecessary scans.
- Nephrogenic systemic fibrosis
- Related: Gadolinium deposition, Informed consent
Rare fibrosing disorder of skin and organs associated with gadolinium exposure in patients with severe renal impairment; risk is minimized by screening renal function and using macrocyclic agents.
- PI-RADS
- Related: LI-RADS
Standardized reporting system for prostate multiparametric MRI that assigns a category from 1 to 5 reflecting the likelihood that a lesion is clinically significant cancer, guiding biopsy decisions.
- LI-RADS
- Related: PI-RADS
Standardized system for interpreting liver imaging in patients at risk for hepatocellular carcinoma, categorizing observations from definitely benign to definitely malignant and guiding management.
- BI-RADS
- Related: PI-RADS
Standardized lexicon and final assessment category for breast imaging, ranging from 0 for incomplete to 6 for known biopsy-proven malignancy, with defined management recommendations for each category.
- Double-contrast barium enema
- Related: Contrast agent
Fluoroscopic examination of the colon using high-density barium and insufflated air to coat the mucosa; largely replaced by colonoscopy and CT colonography but still used selectively.
- Contrast agent
- Related: K-edge, Nephrogenic systemic fibrosis
Substance administered to alter tissue attenuation or signal and improve conspicuity of structures; examples include iodinated compounds for radiography and CT and gadolinium chelates for MRI.
- Signal-to-noise ratio
- Related: Quantum mottle, Detective quantum efficiency
Ratio of the strength of the desired signal to the level of background noise in an image; higher values improve lesion detectability and can be traded against resolution or scan time.