ACT Grouts flashcards
ACT Grouts · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Water-cementitious ratio
- Ratio of water weight to cementitious material weight in a grout mix; lower ratios generally increase strength and reduce permeability.
- Neat cement grout
- A mixture of hydraulic cement and water with no aggregate; used for fine cracks, tendon grouting, and void filling.
- Sanded grout
- Grout containing fine sand aggregate; used for wider joints and fills where reduced shrinkage and economy are needed.
- Non-shrink grout
- Grout formulated with expansive additives to offset drying shrinkage, maintaining contact with base plates and anchors.
- Bleeding in grout
- Upward migration of water to the surface of freshly placed grout; excessive bleed leaves voids and weak zones.
- Superplasticizer
- Admixture that increases grout flowability without adding water, allowing low water-cement ratio while maintaining placement ease.
- Retarder
- Admixture that extends grout set time, useful in hot weather or for long placements to prevent premature stiffening.
- Laitance
- Weak, cement-rich layer on a concrete surface from bleeding; must be removed before grouting to ensure bond.
- Saturated-surface-dry
- Condition where substrate pores are filled with water but no free water film remains; ideal for grout bond.
- Acid etching
- Surface preparation using dilute acid to roughen concrete and open pores; followed by thorough flushing before grouting.
- Mechanical scarification
- Surface roughening by grinding, shot blasting, or scarifying to remove laitance and create bond profile for grout.
- Substrate temperature limits
- Concrete below about 40 F or above about 90 F affects grout hydration, set time, and shrinkage; adjust protection accordingly.
- Curing compound interference
- Membrane curing compounds left on a surface can block bond of sealants, toppings, or subsequent grout layers.
- Tremie placement
- Method of placing grout through a vertical pipe kept submerged in fresh grout to prevent segregation and water washout.
- Pressure injection
- Grouting method that pumps grout into cracks or voids under controlled pressure until material appears at adjacent vents.
- Preplaced-aggregate method
- Technique of filling a coarse-aggregate bed by pumping grout from the bottom up, displacing air and water.
- Progressive cavity pump
- Positive-displacement pump suited to sanded grout; moves material at steady rate with low segregation risk.
- Cold joint in grout
- Interface formed when fresh grout is placed against grout that has already begun to set; a weak plane unless deliberately formed.
- Consolidation by rodding
- Mechanical working of fresh grout to release entrapped air; over-vibration can cause segregation and bleeding.
- Grout flow cone
- Device measuring efflux time in seconds to indicate grout consistency and flowability for placement control.
- Wet burlap curing
- Moist curing method using continuously wetted burlap to keep grout surface hydrated during early strength gain.
- Plastic shrinkage cracking
- Cracks that form in fresh grout when surface evaporation exceeds bleed water; controlled by windbreaks, shading, and curing.
- Penetrating sealer
- Sealer that soaks into grout pores and reacts to repel water while leaving the surface breathable, unlike film formers.
- Cold weather grouting
- Grouting practice maintaining grout and substrate above about 40 F with heaters and blankets until adequate strength develops.
- Evaporation rate factors
- Air temperature, grout temperature, relative humidity, and wind speed together determine moisture loss and cracking risk.
- Compressive strength specimens
- Cube or cylinder samples cast from the placed grout batch and cured under standard conditions to verify mix strength.
- Restrained expansion test
- Test measuring expansion of non-shrink grout under restraint to confirm it offsets shrinkage and maintains contact.
- Sampling at placement
- Grout test samples taken at the point of placement rather than the mixer, so results reflect installed material.
- Silica dust exposure
- Respirable crystalline silica from sanded grout requires dust controls and respiratory protection under OSHA 1926.1153.
- Cement chemical burns
- Alkaline cement in grout can cause skin and eye burns; gloves, eye protection, and prompt washing are required.
- Confined space grouting
- Grouting in tanks or vaults requires atmospheric testing, ventilation, and an attendant under OSHA 1910.146.
- ASTM C1107
- Standard specification for packaged, dry, hydraulic-cement non-shrink grout used for structural and equipment support.