AK Plumber study materials
AK Plumber study resources

AK Plumber flashcards

AK Plumber · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Fixture unit (FU)
A unit of measure representing the probable load a plumbing fixture places on the drainage or water supply system, used to size piping.
Developed length
The total length of pipe measured along its centerline plus equivalent lengths for fittings and valves, used in sizing calculations.
Building drain
The lowest piping of a drainage system that receives discharge from soil and waste stacks and conveys it to the building sewer.
Building sewer
The pipe that conveys sewage from the building drain to the public sewer or private disposal system, starting outside the building wall.
Trap seal depth
The vertical distance between the crown weir of a trap and the top of the water seal, which must be 2 to 4 inches.
Vent stack termination
A vent must extend at least 6 inches above the roof and be located away from windows and air intakes to prevent odor entry.
Wet vent
A single pipe that serves as both a drain for one fixture and a vent for another, permitted only under code-specified conditions.
Cleanout requirement
An accessible fitting with a removable plug installed at the base of stacks, building drains, and at large changes of direction for clearing stoppages.
Backwater valve
A device installed on a drainage line to prevent sewage from reversing into the building when the public sewer surcharges.
Grease interceptor
A tank that separates and retains fats, oils, and grease from wastewater before it enters the sanitary sewer, required for commercial kitchens.
Air gap
The unobstructed vertical distance between a water supply outlet and the flood-level rim of a receptacle; the most reliable backflow prevention.
Pressure-reducing valve
A device installed on a water service to lower incoming pressure to a safe level when system pressure exceeds the code maximum.
Water hammer arrestor
A device with a trapped air chamber installed near quick-closing valves to absorb hydraulic shock and prevent pipe noise and damage.
T&P relief valve
A temperature and pressure relief valve that opens to discharge water when the heater exceeds its rated temperature or pressure limits.
Expansion tank
A tank installed in a closed water system to absorb the increased volume caused by thermal expansion and protect the system.
Sediment trap
A fitting installed on a gas line ahead of an appliance's controls to catch dirt and debris and protect the gas valve.
Combustion air opening
A permanent opening supplying air to an appliance; indoor air openings require 1 sq in. per 1,000 Btu/h of input.
Longest run method
A gas pipe sizing method that measures the longest path from the meter to the farthest appliance to select pipe size from capacity tables.
Flood-level rim
The edge of a fixture over which water would overflow onto the floor; it determines required backwater and air gap protection.
Fixture clearance
The minimum free space required around a fixture, such as 15 inches from a water closet centerline to a side wall.
Standpipe
A vertical pipe that receives the discharge from an appliance such as a clothes washer and connects to a trapped drain.
Roof drain
A drain installed on a roof to collect storm water and convey it to a storm drainage system, separate from the sanitary sewer.
Storm drainage separation
The rule that storm water from roofs, yards, and foundations must not connect to the sanitary sewer system.
Permit requirement
A permit must be obtained from the authority having jurisdiction before installing or altering plumbing, with minor repairs exempt.
Authority having jurisdiction
The official or agency responsible for enforcing the plumbing code and approving installations, materials, and inspections.
Rough-in inspection
An inspection performed after piping is installed but before it is concealed, to verify code compliance of drains, vents, and supplies.
Slope conversion
A 1/4 inch per foot slope equals about 2.08 percent grade, calculated as rise divided by run times 100.
Trench protection
Excavations 5 feet or deeper require shoring, sloping, or shielding, and a competent person must inspect the trench daily.
Confined space entry
Entry into tanks, vaults, or sewers requires atmospheric testing, ventilation, and a trained attendant standing by outside.
Utility locating
The practice of calling the locating service before digging to mark underground utilities and prevent strikes and injuries.
Water service burial depth
A water service pipe must be buried below the local frost line to prevent freezing and loss of service.
Drainage pipe support
Horizontal drainage piping must be supported at intervals not exceeding 4 feet, and vertical stacks at each floor.