Source Water and Water Quality Characteristics

  • A public water system provides water for human consumption through pipes to at least 15 service connections or regularly serves at least 25 people for at least 60 days per year.

  • Surface water sources require filtration and disinfection; groundwater under the direct influence of surface water (GWUDI) is generally treated and monitored as surface water.

  • Turbidity measures suspended particles that scatter light; high turbidity can shield pathogens from disinfection and increases chlorine demand.

  • Federal MCLs include nitrate 10 mg/L as N, nitrite 1 mg/L as N, arsenic 0.010 mg/L, lead action level 0.015 mg/L, and copper action level 1.3 mg/L.

  • Alkalinity and pH affect coagulation and corrosion control; low pH and high chloride-to-sulfate ratio can increase lead and copper release.

  • Watershed and wellhead protection programs reduce source contamination; source water assessments identify susceptibility to contamination.

  • Reservoir stratification and turnover can bring low-oxygen water with elevated iron, manganese, and taste-and-odor compounds to intakes.

  • E. coli in source water indicates fecal contamination; total coliforms are used as indicator organisms for treatment and distribution integrity.

Quick reference

Treatment Processes (Coagulation, Flocculation, Sedimentation, Filtration)

  • Coagulation destabilizes particles by neutralizing negative surface charge; common coagulants include alum, ferric chloride, ferric sulfate, and polyaluminum chloride.

  • Alum reacts with natural alkalinity and lowers pH; if alkalinity is insufficient, add lime or soda ash to maintain effective coagulation.

  • Jar tests determine the optimum coagulant dose and pH by simulating coagulation, flocculation, and settling at bench scale.

  • Flocculation is gentle, tapered mixing that grows small particles into settleable floc; typical detention is about 15 to 45 minutes.

  • Sedimentation design uses surface overflow rate (flow divided by surface area), commonly about 0.3 to 1.0 gpm/ft², with detention often 2 to 4 hours.

  • Tube and plate settlers increase effective settling area and improve particle removal in sedimentation basins.

  • Conventional rapid sand filters commonly operate at about 2 to 4 gpm/ft²; backwash typically uses 15 to 20 gpm/ft² with sufficient bed expansion.

  • Filter turbidity limits: combined filter effluent must be 0.3 NTU or less in at least 95% of monthly measurements, and no individual filter may exceed 1.0 NTU.

  • Backwash recycle can return solids and pathogens to the plant; manage recycle flow and turbidity to avoid treatment spikes.

Quick reference

Disinfection and Residual Maintenance

  • CT is disinfectant concentration in mg/L multiplied by contact time in minutes; required CT depends on disinfectant, target pathogen, pH, and temperature.

  • Chlorine demand equals applied dose minus residual after contact; free chlorine reacts with organics, ammonia, iron, and manganese.

  • Breakpoint chlorination occurs when chlorine addition exceeds demand and converts ammonia to chloramines before free chlorine persists; the breakpoint is roughly 7.6 lb Cl2 per lb ammonia-N.

  • Free chlorine is a stronger disinfectant; combined chlorine (chloramine) is weaker but more persistent and typically forms fewer regulated disinfection byproducts.

  • The MRDL for chlorine and chloramine is 4.0 mg/L as Cl2 in the distribution system; minimum entry-point residuals commonly are 0.2 mg/L free or 0.5 mg/L combined.

  • Maintain a detectable disinfectant residual throughout distribution; record the lowest residual and investigate areas with low residual or high water age.

  • UV disinfection credit depends on validated dose in mJ/cm²; UV inactivates pathogens but leaves no persistent residual.

  • Ozone is a powerful oxidant and disinfectant; in bromide-containing water it can form bromate, a regulated disinfection byproduct.

  • Chlorine dioxide is an effective disinfectant but forms chlorite and chlorate; the chlorite MCL is 1.0 mg/L.

Quick reference

Pumps, Storage, and Distribution System Operations

  • Total dynamic head (TDH) equals static head plus friction and minor losses plus velocity head, expressed in feet of water.

  • Water horsepower = gpm × head (ft) ÷ 3960; brake horsepower = water horsepower ÷ pump efficiency.

  • Affinity laws for a centrifugal pump at constant impeller diameter: flow varies with speed, head with speed squared, and power with speed cubed.

  • Cavitation occurs when local pressure falls below vapor pressure; prevent it by keeping NPSH available above NPSH required.

  • Distribution systems commonly maintain at least 20 psi under normal conditions to prevent backflow and contamination; fire flow may require higher pressure.

  • Storage tanks provide equalization, fire flow, and emergency supply; poor turnover increases water age and can reduce chlorine residual.

  • An air gap is a physical separation between the potable water outlet and the flood level of a receiving vessel and is the highest level of backflow protection.

  • Reduced-pressure-zone (RPZ) assemblies protect against high-hazard backflow and must be tested and maintained according to the primacy agency's requirements.

  • Water hammer from sudden valve closure is controlled with slow-closing valves, surge tanks, air valves, and proper pipeline design.

Quick reference

Regulations, Monitoring, Reporting, Safety, and Calculations

  • The Alabama Department of Environmental Management administers the Safe Drinking Water Act in Alabama and enforces public water system regulations in Alabama Administrative Code Chapter 335-7.

  • Federal MCLs include nitrate 10 mg/L, nitrite 1 mg/L, arsenic 0.010 mg/L, TTHM 80 µg/L, and HAA5 60 µg/L.

  • A positive E. coli result in distribution is an acute risk: notify the primacy agency promptly, issue Tier 1 public notice, and complete corrective actions.

  • Community water systems must deliver a Consumer Confidence Report to customers by July 1 each year covering the previous calendar year.

  • Public notification tiers: Tier 1 is immediate (24 hours) for acute health risk, Tier 2 is within 30 days, and Tier 3 is within 90 days.

  • Alabama operator certification has grades I through IV; higher grades are required for larger or more complex systems, and continuing education is required for renewal.

  • Chlorine gas safety requires gas detection, respiratory protection, emergency shutdown, and trained personnel; sodium hypochlorite degrades with heat and light and can off-gas.

  • Confined space entry requires a permit, atmospheric testing for oxygen, flammables, hydrogen sulfide, and carbon monoxide, plus ventilation, an attendant, and retrieval equipment.

  • Calculations: lb/day = mg/L × 8.34 × MGD; MGD = gpm × 0.00144; dose (mg/L) = lb/day ÷ (8.34 × MGD); detention time = volume ÷ flow using matching units.