ALOA CAL study materials
ALOA CAL study resources

ALOA CAL cheat sheet

ALOA CAL · Keep the key ideas within reach.

Quick reference

General Locksmithing Knowledge

  • Pin tumbler lock: driver pins sit in the bible above the shear line; key pins sit in the plug below it; the plug rotates only when all pin splits align at the shear line.

  • Warded locks use fixed projections (wards) that block all but a matching key; they offer no pin-tumbler security and are bypassed by skeleton keys.

  • Lever tumbler locks gate on lever height: each lever must be lifted to the fence height set by its own cut before the bolt can retract.

  • Disc/detainer locks (e.g., Wafer and Abloy-style) rotate or lift rotating discs; the sidebar releases only when all discs align to a gate.

  • Standard pin-tumbler keyway designations (Kwikset KW1, Schlage SC1, Yale Y1) identify blade profile, not pinning; pinning is set by the key bitting chart.

  • Backset is the distance from the door edge (face plate) to the center of the spindle or cylinder bore; common residential backsets are 2-3/8 in and 2-3/4 in.

  • A deadbolt throws a bolt with no spring latch; a latchbolt has a spring-loaded beveled bolt that retracts on contact with the strike.

  • ANSI/BHMA grade (1, 2, 3) rates cycle endurance and security; Grade 1 is the highest commercial rating, Grade 3 the lowest residential tier.

Quick reference

Mechanical and Electronic Lock Servicing

  • Shear line = the boundary between plug and shell; pin stacks must split exactly there or the plug will not turn; a single overlong driver pin binds the whole cylinder.

  • Binding order is set by manufacturing tolerance: the first pin to bind is the one with the tightest bore fit, so pick tension reveals the binding sequence, not the cut depth.

  • Cylinder pinning math: bottom pin + master wafer + driver pin must equal the chamber depth at the shear line for every shear combination.

  • Electronic access control: fail-safe locks unlock on power loss (life-safety egress); fail-secure locks stay locked on power loss (asset protection).

  • Request-to-exit (REX) devices and crash bars must release egress hardware independent of the access-control decision; code requires free egress at all times.

  • Electric strike types: fail-secure strikes stay locked without power; fail-safe strikes release without power; voltage (12/24 VDC) and duty rating must match the controller.

  • Battery-powered electronic locks degrade first at the motor/clutch; low-battery lockout is a designed behavior, not a fault, and should be tested on a schedule.

  • Lubrication rule: graphite is for dry pin-tumbler cylinders; oil and grease attract dust and gum up springs; silicone spray is preferred for sliding and plastic parts.

  • Door closer sweep and latch speeds are adjusted by separate valves; backcheck controls opening speed and must be set before sweep/latch tuning.

Quick reference

Keying

  • Key bitting depth is measured from the blade shoulder or tip per the manufacturer's spec; spacing is the distance between cut centers along the blade.

  • Root depth vs. shallowest cut: each key cut must be deep enough to clear the bottom pin yet shallow enough to lift the driver pin above the shear line.

  • A key's bitting is read tip-to-bow or bow-to-tip depending on the system; always confirm the direction against the manufacturer's bitting chart before cutting.

  • Macs (maximum adjacent cut specification) limit the depth difference between neighboring cuts so the key will not hang up on the pin stack.

  • First key / last key rules define the highest and lowest legal cuts in a system; any bitting outside that envelope is invalid.

  • Key duplication by code requires the original bitting record; duplicating by tracing an unknown key loses the code and risks an out-of-spec copy.

  • Blanks must match keyway profile and thickness; a blank that is too thick binds in the keyway; too thin causes wobble and wear.

  • Cutting a key: zero the machine on the blank shoulder, cut from the highest (shallowest) cut to the lowest, and deburr the blade before testing in the cylinder.

Quick reference

Master Keying

  • Master keying uses two-level pinning: each chamber holds a bottom pin, a master wafer, and a driver pin so the change key and master key each reach the shear line.

  • Total stack height (bottom + wafer + driver) must equal the chamber depth for every shear combination; if it does not, the cylinder will not key.

  • A master key system has levels: change keys (lowest), sub-master, master, grand master; each level must open its own set and all below it.

  • Cross-keying is when one change key opens another change's lock; it is a defect, not a feature, and must be eliminated during pinning.

  • Number of usable levels is limited by the number of pin depths and chamber count; two-level systems need at least two depths per chamber that do not conflict.

  • A master key bitting must be a valid key under the system's macs and first/last key rules for every lock it opens, not just the master cylinder.

  • Progression charts assign each change a unique bitting; a master key system must be documented so future changes do not collide.

  • Pinning a master cylinder: install bottom pin, then master wafer, then driver; verify with change key, master key, and a non-master key that should fail.

Quick reference

Professional Practices, Ethics, and Safety

  • Verify authority before opening: photo ID plus proof of occupancy (lease, utility bill, or work order) for the address; document the interaction.

  • Never pick or bypass a lock for a customer who cannot prove ownership or authorized access; refer to the property owner or management.

  • Locksmiths are generally required to be licensed or registered in many jurisdictions; confirm local licensing before performing work.

  • Keep a service record: date, address, customer, work performed, parts used, and signature; this protects against liability and disputes.

  • Safety: eye protection when cutting keys or drilling; gloves when handling sharp burrs; do not disable egress hardware even temporarily without a plan to restore it.

  • Fire and life-safety codes require free egress; never install a lock or strike that prevents exit from the inside, regardless of customer request.

  • Customer data (key codes, access codes, alarm codes) is confidential; store it securely and never disclose it to third parties without authorization.

  • Charge and quote in writing; disclose parts, labor, and trip charges before work begins to avoid disputes and comply with consumer-protection rules.