32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Galvanic anode driving voltage
The difference between the anode open-circuit potential and the structure polarized potential; it is the electromotive force that drives protective current in a sacrificial system.
Anode current capacity
Total charge an anode can deliver over its life, computed from net mass, theoretical capacity, current efficiency, and utilization factor divided by design life.
Anode resistance formula
For a vertical rod anode in homogeneous soil, R = (ρ/2πL)[ln(4L/d) − 1], where ρ is soil resistivity, L is length, and d is diameter.
100 mV polarization criterion
A protection criterion requiring at least a 100 mV negative shift of structure potential from its native potential, measured after IR drop is removed.
Zinc anode limitation
Zinc anodes can passivate in low-resistivity, high-pH, or sulfate-rich soils, reducing current output; magnesium is preferred in such environments.
Anode utilization factor
Fraction of anode mass actually consumed before the anode reaches end of life; typically about 0.5 for slender anodes and 0.85 for compact anodes.
Sacrificial anode spacing
Anode placement determined by current distribution needs, coating damage locations, and geometry; spacing controls how evenly protection reaches the structure.
Seawater protection criterion
In seawater, -0.80 V versus Ag/AgCl is a common protection criterion for steel, distinct from the -0.85 V versus Cu/CuSO4 soil criterion.
Impressed current rectifier sizing
Rectifier DC voltage must exceed circuit resistance times design current plus back-EMF; current rating includes margin for coating degradation and seasonal changes.
Total circuit resistance
Sum of anode-to-electrolyte resistance, structure-to-electrolyte resistance, and cable/connection resistance; it sets the rectifier voltage needed for a given current.
MMO anode
Mixed metal oxide coated titanium anode used in impressed current systems; low consumption rate and high current density capability make it long-lived.
Coke breeze backfill
Carbonaceous backfill around impressed current anodes that lowers anode resistance, extends anode life, and improves current distribution into the electrolyte.
High-silicon cast iron anode
Impressed current anode material suited to soil and freshwater; consumption rate and current density limits depend on environment and backfill.
Coating breakdown factor
Multiplier applied to coated area current density to account for coating degradation over time; it raises design current as the coating ages.
Stray current interference
Current from a CP system or other DC source that enters a nearby metallic structure and discharges elsewhere, causing accelerated corrosion; mitigated by bonds or shielding.
Graphite anode
Impressed current anode material with low consumption rate in many soils; requires backfill and careful current density control to avoid damage.
Rectifier transformer taps
Adjustable taps on the rectifier transformer that allow output voltage to be set to match actual circuit resistance and seasonal soil resistivity changes.
Current demand calculation
Design current equals protected area times current density times coating breakdown factor; coating quality strongly reduces required current and rectifier size.
Platinum-niobium anode
Impressed current anode used in seawater and other aggressive environments; the platinum coating provides low consumption and high current density capability.
Attenuation coefficient
α = sqrt(r/R), where r is longitudinal resistance per unit length and R is coating leakage resistance to earth per unit length; it controls how potential decays with distance.
Attenuation equation
Potential at distance x along a protected structure is E(x) = E0 × exp(−αx), where E0 is the potential at the drain point and α is the attenuation coefficient.
Longitudinal resistance
Resistance per unit length of the pipe or structure metal; higher longitudinal resistance increases attenuation and shortens the effective protection distance.
Coating leakage resistance
Resistance per unit length between structure and electrolyte through the coating; better coatings give higher R, larger α, and shorter attenuation distance.
Wenner four-pin method
Field method for measuring soil resistivity using four equally spaced pins; resistivity = 2πaR, where a is pin spacing and R is measured resistance.
Polarization definition
The negative shift of structure potential from its free-corrosion potential toward the protection potential; it measures CP effectiveness rather than current alone.
IR drop
Voltage error in potential measurements caused by current flowing through electrolyte resistance; removed by instant-off readings to reveal true polarized potential.
Current density criterion
Design current per unit area of protected surface; typical values are 10-25 mA/m² for coated steel in soil, with higher values for bare steel.
Reference electrode types
Cu/CuSO4 for soils, Ag/AgCl for seawater, and saturated calomel (SCE) in laboratory work; each has a defined potential offset used to compare readings.
Ohm's law in CP
V = I × R; current output equals driving potential divided by total circuit resistance, linking anode resistance, soil resistivity, and rectifier voltage.
Protection distance
Distance along a structure over which potential remains at or beyond the protection criterion; governed by attenuation coefficient and drain point potential.
Coating conductance
Per-unit-length leakage conductance (1/R) between structure and electrolyte; damaged or bare coating raises conductance and current demand.
Native potential
The free-corrosion potential of a structure before CP is applied; it is the baseline from which polarization shift and the 100 mV criterion are measured.