Quick reference

Metallurgy

  • Carbon equivalent (IIW): CE = C + Mn/6 + (Cr+Mo+V)/5 + (Ni+Cu)/15; CE above ~0.40 raises weld cracking risk in carbon steels.

  • Galvanic series ranks alloys by corrosion potential in seawater; the more active (anodic) member of a couple corrodes, and potential separation drives the rate.

  • Pitting resistance equivalent number: PREN = Cr + 3.3(Mo) + 16(N); values above ~40 indicate high resistance to chloride pitting in stainless steels.

  • Sensitization of austenitic stainless occurs when chromium carbides precipitate at grain boundaries (roughly 425-815 C), depleting adjacent chromium below ~12 percent.

  • Anodic polarization curves showing an active-passive transition identify alloys capable of passivation; the passive current density indicates the maintenance current needed.

  • Austenitic stainlesses are generally not susceptible to hydrogen embrittlement but are prone to chloride stress corrosion cracking above ~60 C.

  • Carbon steel corrosion rate roughly doubles per 10 C rise in temperature up to ~80 C, after which oxygen solubility decline can reduce rates.

  • Hardness above ~22 HRC in carbon and low-alloy steels increases sulfide stress cracking susceptibility per NACE MR0175/ISO 15156.

Quick reference

Chemical Treatment

  • Corrosion inhibitor efficiency: %E = (CR_blank - CR_inhibited)/CR_blank x 100; measured by weight loss, LPR, or RCE.

  • Film-forming amine inhibitors partition to the metal surface; their performance depends on continuous or intermittent injection to maintain a persistent film.

  • Oxygen scavengers (sulfite, hydrazine, DEHA) remove dissolved O2; sulfite is unsuitable above ~150 C due to breakdown to sulfide.

  • pH control targets: cooling water typically 7.5-9.0; boiler water coordinated phosphate programs maintain pH 9.5-10.5 to prevent caustic and acidic attack.

  • Scale inhibitors (phosphonates, polyacrylates) work by threshold inhibition and crystal distortion; over-dosing can cause precipitation of the inhibitor itself.

  • Biocide programs alternate oxidizing (hypochlorite, chlorine dioxide) and non-oxidizing (quaternary amines, glutaraldehyde) agents to limit resistance.

  • Residual monitoring (e.g., 1-5 ppm sulfite, 0.1-0.5 ppm amine) confirms chemical delivery; treat residuals as a leading indicator of treatment efficacy.

Quick reference

Coating Systems

  • Coating resistance: R = rho * t / A, where rho is resistivity, t is dry film thickness, and A is area; thicker films increase resistance.

  • Surface preparation per SSPC-SP 10 (Near-White) or SP 5 (White Metal) is required for immersion service; residual chloride below ~3-5 ug/cm2 is a common acceptance limit.

  • Anchor profile typically 1.5-3.5 mils (38-89 um) for high-performance systems; excessive profile can leave peaks uncoated.

  • Holiday (pinhole) detection uses high-voltage spark testers; voltage is set by dry film thickness per manufacturer (commonly ~100 V per mil).

  • Cathodic disbondment resistance is critical for coatings on cathodically protected structures; test per ASTM G8 or G95.

  • Fusion-bonded epoxy (FBE) and three-layer polyolefin are standard for buried pipelines; FBE thickness is typically 350-500 um.

  • Coating adhesion is measured by pull-off (ASTM D4541) or knife/tape tests; failure mode (adhesive vs cohesive) guides remediation.

Quick reference

Internal Corrosion

  • CO2 corrosion (sweet) prediction uses models such as NORSOK M-506 or de Waard-Milliams; corrosion rate increases with CO2 partial pressure and temperature.

  • H2S partial pressure above 0.05 psi (0.0035 bar) triggers sulfide stress cracking considerations for susceptible steels per NACE MR0175.

  • Flow regime matters: slug and annular flow increase wall shear stress and can strip inhibitor films; stratified flow promotes water wetting.

  • Water wetting is the prerequisite for internal corrosion; oil-wet surfaces may be protected even without chemical treatment.

  • Erosion-corrosion threshold often approximated by API RP 14E: V_e = C / sqrt(rho_m), with C = 100 (continuous) or 125-200 (intermittent).

  • Pigging and batch treatment are used to distribute inhibitors and remove solids; intelligent pigging (ILI) detects metal loss with MFL or UT tools.

  • Inhibitor residual and coupon/LPR monitoring confirm treatment; corrosion coupons give time-averaged rates, ER probes give real-time trends.

Quick reference

Cathodic Protection

  • Criterion: -850 mV (Cu/CuSO4) polarized potential or 100 mV polarization shift; native (IR-free) potentials are used to avoid IR drop error.

  • CP current requirement: I = A * i * (1 - E), where A is coated area, i is bare current density, and E is coating efficiency (fraction).

  • Anode resistance (vertical rod, Dwight formula): R = (rho / (2piL)) * (ln(4L/d) - 1), where rho is soil resistivity, L length, d diameter.

  • Sacrificial anodes: magnesium for high-resistivity soils (<~3000 ohm-cm), zinc for low-resistivity/seawater, aluminum for offshore.

  • ICCP rectifier output is set to maintain protection; current increases as coating degrades, and a rising current trend signals coating failure.

  • Close-interval surveys (CIS) with a moving reference electrode locate coating defects and confirm protection along a pipeline.

  • Stray current corrosion occurs where DC current leaves a structure to earth; mitigation uses drainage bonds or sacrificial anodes at the discharge point.

Quick reference

Safety Planning

  • Confined space entry requires atmospheric testing for O2 (19.5-23.5 percent), LEL (<10 percent), and H2S (<10 ppm or site limit) before and during entry.

  • Hot work near coatings or tanks requires gas testing; LEL readings above 10 percent prohibit hot work, and continuous monitoring is required.

  • Job Safety Analysis (JSA) identifies hazards, controls, and responsibilities before work; it is reviewed with the crew and updated when conditions change.

  • Cathodic protection rectifiers are DC hazards; lockout/tagout and voltage verification precede work on rectifier circuits.

  • Chemical handling requires SDS review, PPE selection, and spill response planning; incompatible chemicals (acids and hypochlorite) must be segregated.

  • Lifting and rigging plans govern anode and pipe handling; load charts, tag lines, and exclusion zones are documented in the lift plan.

  • Emergency response includes muster points, communication, and rescue plans for confined space and elevated work; rescue equipment must be staged before entry.