ANS CNP study materials
ANS CNP study resources

ANS CNP cheat sheet

ANS CNP · Keep the key ideas within reach.

Quick reference

Nuclear Physics and Reactor Theory

  • Fission of U-235 by a thermal neutron releases about 200 MeV, roughly 2.5 prompt neutrons, and energy split among fission fragments, neutrons, gamma rays, and neutrinos.

  • Six-factor formula: k_eff = epsilon * p * f * eta * P_FNL * P_TNL, where epsilon is fast fission factor, p resonance escape probability, f thermal utilization, eta reproduction factor, and the last two are non-leakage terms.

  • Criticality condition is k_eff = 1; k_eff < 1 is subcritical and k_eff > 1 is supercritical. Reactivity rho = (k_eff - 1)/k_eff, often expressed in pcm (1 pcm = 1e-5).

  • Prompt neutron lifetime in a thermal reactor is on the order of 1e-4 s, which is why delayed neutrons (about 0.65% of total in U-235) are essential for controllability.

  • Delayed neutron fraction beta for U-235 is about 0.0065; the reactor is prompt critical when reactivity exceeds beta.

  • Inhour equation relates stable reactor period T to reactivity through the six delayed neutron groups; for small positive reactivity, T is approximately (l* + sum(beta_i/(lambda_i - 1/T)))/rho.

  • Four-factor formula for an infinite thermal reactor: k_inf = epsilon * p * f * eta; leakage is added by the non-leakage probabilities from the buckling and migration area.

  • Xenon-135 has a thermal absorption cross section near 2.6 million barns and produces post-shutdown reactivity transients; samarium-149 is a stable, slow-saturating fission product poison.

Quick reference

Reactor Operations and Control

  • Control rods are withdrawn to add positive reactivity; rod worth is greatest where the neutron flux is highest, so differential worth curves peak near the core midplane.

  • The startup rate (SUR) in decades per minute relates to reactor period by SUR = 26.06 / T, with T in seconds.

  • A reactor period of 30 s corresponds to about 0.87 decades per minute; operators typically limit positive periods to avoid rapid power escalation.

  • Axial flux shape is affected by xenon redistribution; flux tilting can occur when local xenon burnout or buildup shifts the power distribution.

  • The moderator temperature coefficient is typically negative in PWRs because water density decreases with temperature, reducing moderation; void coefficient behavior varies by design.

  • Boration adds negative reactivity by increasing thermal neutron absorption; dilution adds positive reactivity. Boron letdown and makeup must be controlled by procedure.

  • Approach to criticality uses the inverse-counts (1/M) plot; a plot trending toward zero at the critical point indicates a valid approach.

  • Surveillance testing of reactor trip breakers and rod drop times verifies scram capability; rod drop time from full out to dashpot entry is typically under 2 s for PWRs.

Quick reference

Nuclear Safety and Regulatory Compliance

  • Defense in depth uses multiple independent barriers and levels of protection: fuel matrix, cladding, primary pressure boundary, containment, and emergency systems.

  • The general design criteria in 10 CFR Part 50 Appendix A establish requirements such as single-failure criteria and protection against anticipated operational occurrences.

  • Design-basis accidents (DBAs) include loss-of-coolant accidents, rod ejection, steam line breaks, and main feedwater line breaks; they bound the safety analysis.

  • Emergency core cooling system acceptance criteria in 10 CFR 50.46 limit peak cladding temperature to 2200 F and local cladding oxidation to 17% of the initial wall thickness.

  • Technical specifications define limiting conditions for operation, surveillance requirements, and action statements; exceeding an LCO requires prompt action per the action statement.

  • The safety limit is the boundary that must not be exceeded to protect the public and fuel; it is more restrictive than the design basis and is enforced by reactor protection setpoints.

  • 10 CFR Part 20 establishes occupational dose limits; 10 CFR Part 50 and Part 100 govern reactor site criteria and radiological emergency planning.

  • Event reporting under 10 CFR 50.72 and 50.73 requires notification of specified events within 1, 4, or 8 hours depending on severity.

Quick reference

Radiation Protection and Health Physics

  • Occupational whole-body dose limit is 5 rem (50 mSv) per year; the lens of the eye limit is 15 rem (150 mSv) per year; extremity and skin limit is 50 rem (500 mSv) per year.

  • ALARA means keeping doses as low as reasonably achievable, considering social and economic factors; the three protective principles are time, distance, and shielding.

  • Inverse square law: dose rate from a point source varies as 1/r^2, so doubling distance reduces dose rate by a factor of four.

  • Half-value layer (HVL) is the thickness of material that reduces gamma intensity by half; intensity I = I0 * (1/2)^(x/HVL).

  • Annual public dose limit is 100 mrem (1 mSv) from licensed facilities; the dose constraint for a single source is typically a small fraction of this.

  • Derived air concentration (DAC) and annual limit on intake (ALI) are used to control internal exposure; DAC is the concentration in air that would give an ALI over a working year.

  • Committed effective dose equivalent (CEDE) accounts for internal uptake over 50 years; tritium and iodine-131 are common internal dose contributors in nuclear facilities.

  • Personnel dosimetry uses TLDs, OSLs, or film badges; dosimeters are worn at the collar or torso and must be processed and records maintained per 10 CFR Part 20.

Quick reference

Nuclear Fuel Cycle and Waste Management

  • The front end of the fuel cycle includes uranium mining, conversion to UF6, enrichment, and fuel fabrication; the back end includes storage, reprocessing, and disposal.

  • Enrichment increases the U-235 fraction; natural uranium is about 0.711% U-235, and typical power reactor fuel is enriched to 3-5% U-235.

  • Spent fuel is highly radioactive and thermally hot; it is stored in pools for cooling and shielding before dry cask storage or disposal.

  • High-level waste includes spent fuel and reprocessing raffinate; low-level waste includes contaminated tools, clothing, and resins; transuranic waste is defined by activity above 100 nCi/g of alpha-emitting transuranics with half-life over 20 years.

  • The once-through cycle treats spent fuel as waste; a closed cycle reprocesses fuel to recover uranium and plutonium, reducing waste volume but raising proliferation concerns.

  • Waste classification and disposal requirements are in 10 CFR Part 61 for low-level waste and 10 CFR Part 60/63 for high-level waste geologic disposal.

  • Decay heat from spent fuel decreases over time; after about 5 years, heat output drops enough that forced cooling requirements can be reduced for some storage designs.

  • Waste package acceptance criteria and transportation are governed by 10 CFR Part 71 and DOT regulations; Type B casks are designed for severe accident conditions.

Quick reference

Nuclear Security and Safeguards

  • Physical protection of nuclear facilities is governed by 10 CFR Part 73; it requires a security plan, access controls, and protection against design-basis threats.

  • The IAEA safeguards system uses nuclear material accountancy, containment and surveillance, and inspections to verify that material is not diverted.

  • The Nuclear Non-Proliferation Treaty (NPT) requires non-nuclear-weapon states to accept IAEA safeguards on all nuclear material; the Additional Protocol strengthens verification.

  • Material control and accounting (MC&A) uses item and bulk measurement, material balances, and anomaly investigation to detect diversion.

  • Category I special nuclear material (Pu and U-235 above specified quantities) requires the highest physical protection; Category II and III have progressively lower requirements.

  • Two-person rule and access authorization programs are required for access to vital areas; background checks and fitness-for-duty programs support insider threat mitigation.

  • Security event reporting and drills are required; the design-basis threat defines the adversary capabilities against which the facility must be protected.

  • Cyber security for nuclear facilities is addressed under 10 CFR 73.54, requiring protection of digital computer and communication systems from cyber attacks.

Quick reference

Professional Ethics and Conduct

  • Engineers must hold public safety paramount; when safety and production conflict, safety governs and the conflict must be escalated through the chain of command.

  • The duty to report safety concerns includes internal reporting and, where required, reporting to regulators; retaliation for good-faith reporting is prohibited.

  • Falsification of records, test results, or operator logs is a serious violation that can lead to license action and criminal liability under 18 U.S.C. 1001.

  • Operators must follow the plant technical specifications and procedures; deviations require documented justification and approval, not informal shortcuts.

  • Conflicts of interest must be disclosed; engineers should avoid accepting gifts or favors that could influence technical judgment.

  • Professional competence requires maintaining qualifications, completing required training, and self-assessing before performing safety-related tasks.

  • Whistleblower protections exist under federal law and 10 CFR 50.7; discrimination against employees for raising safety concerns is prohibited.

  • Ethical decision-making in nuclear settings uses stepwise reasoning: identify the issue, gather facts, evaluate options against codes and regulations, decide, and document.

Quick reference

Nuclear Physics and Reactor Theory

  • Fission of U-235 by a thermal neutron releases about 200 MeV, roughly 2.5 prompt neutrons, and energy split among fission fragments, neutrons, gamma rays, and neutrinos.

  • Six-factor formula: k_eff = epsilon * p * f * eta * P_FNL * P_TNL, where epsilon is fast fission factor, p resonance escape probability, f thermal utilization, eta reproduction factor, and the last two are non-leakage terms.

  • Criticality condition is k_eff = 1; k_eff < 1 is subcritical and k_eff > 1 is supercritical. Reactivity rho = (k_eff - 1)/k_eff, often expressed in pcm (1 pcm = 1e-5).

  • Prompt neutron lifetime in a thermal reactor is on the order of 1e-4 s, which is why delayed neutrons (about 0.65% of total in U-235) are essential for controllability.

  • Delayed neutron fraction beta for U-235 is about 0.0065; the reactor is prompt critical when reactivity exceeds beta.

  • Inhour equation relates stable reactor period T to reactivity through the six delayed neutron groups; for small positive reactivity, T is approximately (l* + sum(beta_i/(lambda_i - 1/T)))/rho.

  • Four-factor formula for an infinite thermal reactor: k_inf = epsilon * p * f * eta; leakage is added by the non-leakage probabilities from the buckling and migration area.

  • Xenon-135 has a thermal absorption cross section near 2.6 million barns and produces post-shutdown reactivity transients; samarium-149 is a stable, slow-saturating fission product poison.

Quick reference

Reactor Operations and Control

  • Control rods are withdrawn to add positive reactivity; rod worth is greatest where the neutron flux is highest, so differential worth curves peak near the core midplane.

  • The startup rate (SUR) in decades per minute relates to reactor period by SUR = 26.06 / T, with T in seconds.

  • A reactor period of 30 s corresponds to about 0.87 decades per minute; operators typically limit positive periods to avoid rapid power escalation.

  • Axial flux shape is affected by xenon redistribution; flux tilting can occur when local xenon burnout or buildup shifts the power distribution.

  • The moderator temperature coefficient is typically negative in PWRs because water density decreases with temperature, reducing moderation; void coefficient behavior varies by design.

  • Boration adds negative reactivity by increasing thermal neutron absorption; dilution adds positive reactivity. Boron letdown and makeup must be controlled by procedure.

  • Approach to criticality uses the inverse-counts (1/M) plot; a plot trending toward zero at the critical point indicates a valid approach.

  • Surveillance testing of reactor trip breakers and rod drop times verifies scram capability; rod drop time from full out to dashpot entry is typically under 2 s for PWRs.

Quick reference

Nuclear Safety and Regulatory Compliance

  • Defense in depth uses multiple independent barriers and levels of protection: fuel matrix, cladding, primary pressure boundary, containment, and emergency systems.

  • The general design criteria in 10 CFR Part 50 Appendix A establish requirements such as single-failure criteria and protection against anticipated operational occurrences.

  • Design-basis accidents (DBAs) include loss-of-coolant accidents, rod ejection, steam line breaks, and main feedwater line breaks; they bound the safety analysis.

  • Emergency core cooling system acceptance criteria in 10 CFR 50.46 limit peak cladding temperature to 2200 F and local cladding oxidation to 17% of the initial wall thickness.

  • Technical specifications define limiting conditions for operation, surveillance requirements, and action statements; exceeding an LCO requires prompt action per the action statement.

  • The safety limit is the boundary that must not be exceeded to protect the public and fuel; it is more restrictive than the design basis and is enforced by reactor protection setpoints.

  • 10 CFR Part 20 establishes occupational dose limits; 10 CFR Part 50 and Part 100 govern reactor site criteria and radiological emergency planning.

  • Event reporting under 10 CFR 50.72 and 50.73 requires notification of specified events within 1, 4, or 8 hours depending on severity.

Quick reference

Radiation Protection and Health Physics

  • Occupational whole-body dose limit is 5 rem (50 mSv) per year; the lens of the eye limit is 15 rem (150 mSv) per year; extremity and skin limit is 50 rem (500 mSv) per year.

  • ALARA means keeping doses as low as reasonably achievable, considering social and economic factors; the three protective principles are time, distance, and shielding.

  • Inverse square law: dose rate from a point source varies as 1/r^2, so doubling distance reduces dose rate by a factor of four.

  • Half-value layer (HVL) is the thickness of material that reduces gamma intensity by half; intensity I = I0 * (1/2)^(x/HVL).

  • Annual public dose limit is 100 mrem (1 mSv) from licensed facilities; the dose constraint for a single source is typically a small fraction of this.

  • Derived air concentration (DAC) and annual limit on intake (ALI) are used to control internal exposure; DAC is the concentration in air that would give an ALI over a working year.

  • Committed effective dose equivalent (CEDE) accounts for internal uptake over 50 years; tritium and iodine-131 are common internal dose contributors in nuclear facilities.

  • Personnel dosimetry uses TLDs, OSLs, or film badges; dosimeters are worn at the collar or torso and must be processed and records maintained per 10 CFR Part 20.

Quick reference

Nuclear Fuel Cycle and Waste Management

  • The front end of the fuel cycle includes uranium mining, conversion to UF6, enrichment, and fuel fabrication; the back end includes storage, reprocessing, and disposal.

  • Enrichment increases the U-235 fraction; natural uranium is about 0.711% U-235, and typical power reactor fuel is enriched to 3-5% U-235.

  • Spent fuel is highly radioactive and thermally hot; it is stored in pools for cooling and shielding before dry cask storage or disposal.

  • High-level waste includes spent fuel and reprocessing raffinate; low-level waste includes contaminated tools, clothing, and resins; transuranic waste is defined by activity above 100 nCi/g of alpha-emitting transuranics with half-life over 20 years.

  • The once-through cycle treats spent fuel as waste; a closed cycle reprocesses fuel to recover uranium and plutonium, reducing waste volume but raising proliferation concerns.

  • Waste classification and disposal requirements are in 10 CFR Part 61 for low-level waste and 10 CFR Part 60/63 for high-level waste geologic disposal.

  • Decay heat from spent fuel decreases over time; after about 5 years, heat output drops enough that forced cooling requirements can be reduced for some storage designs.

  • Waste package acceptance criteria and transportation are governed by 10 CFR Part 71 and DOT regulations; Type B casks are designed for severe accident conditions.

Quick reference

Nuclear Security and Safeguards

  • Physical protection of nuclear facilities is governed by 10 CFR Part 73; it requires a security plan, access controls, and protection against design-basis threats.

  • The IAEA safeguards system uses nuclear material accountancy, containment and surveillance, and inspections to verify that material is not diverted.

  • The Nuclear Non-Proliferation Treaty (NPT) requires non-nuclear-weapon states to accept IAEA safeguards on all nuclear material; the Additional Protocol strengthens verification.

  • Material control and accounting (MC&A) uses item and bulk measurement, material balances, and anomaly investigation to detect diversion.

  • Category I special nuclear material (Pu and U-235 above specified quantities) requires the highest physical protection; Category II and III have progressively lower requirements.

  • Two-person rule and access authorization programs are required for access to vital areas; background checks and fitness-for-duty programs support insider threat mitigation.

  • Security event reporting and drills are required; the design-basis threat defines the adversary capabilities against which the facility must be protected.

  • Cyber security for nuclear facilities is addressed under 10 CFR 73.54, requiring protection of digital computer and communication systems from cyber attacks.

Quick reference

Professional Ethics and Conduct

  • Engineers must hold public safety paramount; when safety and production conflict, safety governs and the conflict must be escalated through the chain of command.

  • The duty to report safety concerns includes internal reporting and, where required, reporting to regulators; retaliation for good-faith reporting is prohibited.

  • Falsification of records, test results, or operator logs is a serious violation that can lead to license action and criminal liability under 18 U.S.C. 1001.

  • Operators must follow the plant technical specifications and procedures; deviations require documented justification and approval, not informal shortcuts.

  • Conflicts of interest must be disclosed; engineers should avoid accepting gifts or favors that could influence technical judgment.

  • Professional competence requires maintaining qualifications, completing required training, and self-assessing before performing safety-related tasks.

  • Whistleblower protections exist under federal law and 10 CFR 50.7; discrimination against employees for raising safety concerns is prohibited.

  • Ethical decision-making in nuclear settings uses stepwise reasoning: identify the issue, gather facts, evaluate options against codes and regulations, decide, and document.