API TES study materials
API TES study resources

API TES cheat sheet

API TES · Keep the key ideas within reach.

Quick reference

Tank Entry Supervision

  • A confined space entry permit is valid only for the specific tank, task, and time window named on it; conditions changing outside that scope void the permit.

  • Atmospheric testing order is oxygen first, then flammables (LEL), then toxics (e.g., H2S); each result must be recorded with time and instrument ID.

  • Acceptable entry atmosphere: oxygen 19.5-23.5% by volume; flammable gas/vapor below 10% LEL; toxics below the applicable exposure limit.

  • The attendant (hole watch) remains outside the tank at the entry point at all times during occupancy and never enters to rescue.

  • Entry supervisor verifies permit conditions, isolation, and atmospheric results before authorizing entry, and cancels the permit when the job ends or conditions change.

  • Rescue plan must be in place before entry: trained rescuers, retrieval equipment, and summoning method; non-entry retrieval is preferred.

  • Continuous or periodic atmospheric monitoring is required when conditions can change (residue, sludge disturbance, adjacent operations); intermittent testing alone is insufficient.

  • Communication between entrant and attendant is maintained continuously; loss of contact triggers evacuation of the entrant.

  • Isolation for entry includes blanking/blinding or double block-and-bleed of all lines, plus lockout/tagout of mixers and other energy sources.

Quick reference

Tank Cleaning and Entry Safety Practices

  • Tank cleaning sequence: isolate, drain, purge/ventilate, test atmosphere, then enter; cleaning must not begin inside until the atmosphere passes.

  • Mechanical ventilation is used to maintain a safe atmosphere; pure oxygen must never be used for ventilation or purging.

  • Sludge and scale can release trapped hydrocarbons or H2S when disturbed, so testing is repeated after agitation or cleaning begins.

  • Lifelines and retrieval systems are rigged before entry so a non-breathing entrant can be removed without a rescuer entering.

  • Intrinsically safe or appropriately rated lighting and tools are used; voltage and equipment class must suit the flammable atmosphere.

  • Water washing and steam cleaning of tanks that contained flammables require bonding/grounding considerations and control of static and hot surfaces.

  • Entrants wear PPE specified by the hazard assessment (e.g., chemical-resistant clothing, respiratory protection, harness); respirators do not substitute for ventilation.

  • A standby rescue team and equipment are staged when non-entry retrieval is not feasible; the attendant never performs entry rescue alone.