AR Water Operator flashcards
AR Water Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT value
- Product of disinfectant residual concentration in mg/L and contact time in minutes, used to demonstrate required pathogen inactivation credit.
- Turbidity combined filter effluent
- Surface water rule limit of 0.3 NTU in at least 95 percent of monthly measurements, with no single reading above 1 NTU.
- Jar test purpose
- Laboratory procedure that simulates coagulation and flocculation to determine optimum coagulant dose and pH for a given raw water.
- Langelier Saturation Index
- Difference between measured pH and saturation pH; negative values indicate corrosive tendency, positive values indicate scale-forming tendency.
- Alum alkalinity demand
- Alum consumes natural alkalinity during coagulation, so low-alkalinity source waters may require lime or caustic addition to maintain pH.
- Cryptosporidium disinfection resistance
- Oocysts are highly resistant to free chlorine; control typically relies on physical removal plus UV or ozone disinfection.
- Minimum distribution pressure
- Distribution systems must maintain positive pressure, commonly a minimum of 20 psi, to prevent backflow and contamination intrusion.
- Water hammer cause
- Sudden velocity change from rapid valve closure or pump trip creates pressure surges; mitigated by slow closure, surge tanks, and air valves.
- Air gap backflow protection
- Physical separation between a potable supply and a receiving vessel; the highest-level and most reliable form of cross-connection protection.
- Unidirectional flushing
- Flushing method sequencing valves to move water at high velocity in one direction, scouring sediment and biofilm from mains.
- Hazen-Williams equation
- Empirical formula relating head loss to flow, pipe diameter, length, and roughness coefficient C; widely used for distribution main design.
- Storage tank turnover
- Regular cycling of stored volume prevents stagnation, residual loss, and water quality degradation in distribution storage facilities.
- Pipe flow velocity
- Velocity equals flow divided by cross-sectional area; design values of roughly 2 to 5 ft/s limit head loss and pipe erosion.
- Membrane filtration coliform method
- Sample is filtered through a membrane, incubated on selective medium, and colonies counted and reported as CFU per 100 mL.
- DPD chlorine method
- Colorimetric test measuring free and total chlorine; combined chlorine is estimated as total minus free chlorine residual.
- Turbidity units
- Nephelometric turbidity is reported in NTU and instruments are calibrated with formazin or approved polymer primary standards.
- Bacteriological holding time
- Collected samples must be chilled and reach the laboratory within a short window, commonly six to eight hours, per state rule.
- Grab versus composite sample
- Grab samples represent one moment in time; composite samples combine flow- or time-proportioned aliquots for loading calculations.
- Method detection limit
- Statistically derived lowest concentration distinguishable from zero; differs from the reporting limit, which is the lowest routinely quantifiable value.
- Chain of custody
- Documentation tracking sample possession, collector, date and time, requested analyses, and each transfer between handlers.
- TTHM MCL
- Stage 2 rule locational running annual average limit of 80 micrograms per liter for total trihalomethanes in distribution systems.
- HAA5 MCL
- Stage 2 rule locational running annual average limit of 60 micrograms per liter for the five regulated haloacetic acids.
- Lead action level
- Ninetyth percentile lead concentration of 0.015 mg/L; exceedance triggers corrosion control treatment, monitoring, and public education.
- Nitrate MCL
- Maximum contaminant level of 10 mg/L expressed as nitrogen; nitrite is limited to 1 mg/L as nitrogen.
- Consumer Confidence Report
- Annual report delivered to customers by July 1 describing source water, detected contaminants, and compliance status of the system.
- Tier 1 public notice
- Immediate notification required within 24 hours for acute violations such as an E. coli MCL exceedance or nitrate exceedance.
- Chlorine gas leak response
- Chlorine is heavier than air; respond from upwind using self-contained breathing apparatus, never a cartridge respirator or dust mask.
- Confined space oxygen range
- Acceptable entry atmosphere is 19.5 to 23.5 percent oxygen; testing for flammables and toxics is also required before entry.
- Hypochlorite and acid mixing
- Combining sodium hypochlorite with acid releases chlorine gas; these chemicals must be stored and fed separately.
- Trench protective system threshold
- Excavations 5 feet or deeper require a protective system; spoils and heavy equipment stay at least 2 feet from the edge.
- Water loss percentage
- Calculated as system input volume minus authorized consumption, divided by system input volume, multiplied by 100.
- Sanitary survey
- Primacy agency inspection of source, treatment, distribution, and management; identified significant deficiencies require corrective action on a schedule.