ARRT Cardiac-Interventional Radiography flashcards
ARRT Cardiac-Interventional Radiography · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Left anterior descending territory
- Supplies the anterior LV wall, the anterior two-thirds of the interventricular septum, and the apex; occlusion produces an anterior infarct with changes in V1–V4.
- Right coronary artery supply
- Supplies the right ventricle and inferior LV wall and gives the SA node branch in about 60% and the AV node branch in about 90% of people.
- Coronary dominance
- Determined by which artery gives rise to the posterior descending artery; right dominant in about 85%, left dominant in 8%, and codominant in 7%.
- Normal ejection fraction
- The fraction of LV end-diastolic volume ejected per beat, calculated as (EDV − ESV)/EDV; normal is 55–70%, and values below 40% indicate reduced systolic function.
- Cardiac output formula
- Cardiac output equals heart rate multiplied by stroke volume, normally 4–8 L/min; cardiac index divides output by body surface area, normal 2.5–4.0 L/min/m².
- Coronary perfusion timing
- Left coronary artery flow occurs predominantly during diastole; the subendocardium is most vulnerable to ischemia because tachycardia shortens the diastolic perfusion period.
- Heart sound origins
- S1 is produced by closure of the mitral and tricuspid valves at the onset of systole; S2 by closure of the aortic and pulmonic valves at end-systole.
- Aortic stenosis severity
- Severe aortic stenosis is defined by valve area under 1.0 cm², mean gradient of 40 mmHg or more, or peak velocity of 4 m/s or greater.
- French catheter sizing
- One French equals one-third of a millimeter; diagnostic coronary catheters are usually 4–6 Fr, while guide catheters used for intervention are 5–8 Fr.
- Judkins catheter curves
- Judkins left and right preformed curves engage the coronary ostia in a normal aorta; Amplatz curves are selected for dilated or tortuous ascending aortas.
- Significant stenosis criteria
- Angiographically, a 70% or greater diameter narrowing in a major epicardial artery, or 50% or greater in the left main, is considered flow-limiting.
- FFR threshold
- Fractional flow reserve of 0.80 or less across a stenosis indicates hemodynamic significance and benefit from revascularization; a value above 0.80 supports deferring intervention.
- ACT target during PCI
- Activated clotting time should reach 250–300 seconds with unfractionated heparin during PCI, or 200–250 seconds when a glycoprotein IIb/IIIa inhibitor is used.
- TIMI flow grades
- Grade 0 is no flow, 1 is faint penetration, 2 is partial filling, and 3 is normal brisk flow; TIMI 3 is the desired result after PCI.
- Balloon inflation pressures
- Percutaneous transluminal coronary angioplasty balloons are typically inflated to 8–14 atm; stents are deployed at manufacturer nominal pressure and post-dilated for malapposition.
- Transradial access advantage
- Radial artery catheterization reduces access-site bleeding and allows early ambulation; radial spasm is prevented with intra-arterial vasodilators such as nitroglycerin or verapamil.
- Cine frame acquisition rate
- Coronary cineangiography is usually acquired at 15 frames per second, with 30 frames per second reserved for rapid motion; pulsed fluoroscopy runs 7.5–15 frames per second.
- LAO cranial projection
- This view demonstrates the mid and distal left anterior descending artery and its diagonal branches, with the vessel lengthened and less foreshortened.
- Foreshortening effect
- A vessel appears shortened when it is not perpendicular to the x-ray beam; optimal projections place the segment of interest perpendicular to the central ray.
- Magnification and dose
- Reducing field of view from 20 cm to 15 cm magnifies the image but increases patient dose roughly in proportion to the square of the magnification factor.
- Pixel size calculation
- Pixel size equals field-of-view width divided by matrix width; a 20 cm field of view with a 1024 matrix yields pixels of approximately 0.2 mm.
- Quantum mottle
- Speckled image noise caused by too few x-ray photons reaching the detector; it is worsened by low dose and large patient thickness and reduced by higher detector dose.
- Roadmap misregistration artifact
- Roadmapping subtracts a stored mask from contrast-enhanced frames; patient, cardiac, or table motion between mask and contrast frames produces misregistration artifact.
- Last image hold
- The final fluoroscopic frame is retained on the monitor after exposure stops, allowing review and reducing total fluoroscopy time and radiation dose.
- Occupational dose limits
- NCRP annual limits are 50 mSv whole body, 150 mSv lens of the eye, and 500 mSv extremities; ICRP recommends a stricter 20 mSv annual lens limit.
- Inverse square law
- Scatter intensity decreases with the square of the distance from the patient; doubling the distance from the patient reduces operator dose to one quarter.
- Typical angiographic effective dose
- Diagnostic coronary angiography delivers roughly 3–10 mSv effective dose, while complex percutaneous coronary intervention may exceed 15 mSv.
- Lead apron attenuation
- A 0.5 mm lead-equivalent apron attenuates approximately 90–95% of scattered photons at typical fluoroscopic energies; lighter 0.35 mm aprons are used when justified.
- Fluoroscopy dose reduction
- Pulsed fluoroscopy, tight collimation, last image hold, avoidance of magnification, and keeping the detector close to the patient all lower patient and staff dose.
- Radiation skin injury threshold
- Transient erythema may appear at about 2 Gy absorbed skin dose and epilation at about 3–5 Gy, so cumulative dose should be tracked in prolonged procedures.
- Contrast premedication regimen
- For prior contrast reaction, elective premedication is prednisone 50 mg orally at 13, 7, and 1 hour before the procedure plus diphenhydramine 50 mg.
- Declared pregnant worker limit
- NCRP recommends a conceptus dose limit of 0.5 mSv per month and 5 mSv over the entire gestation for a declared pregnant radiation worker.