ARRT Radiography flashcards
ARRT Radiography · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Normal adult heart rate
- The typical resting heart rate for an adult is 60 to 100 beats per minute; below 60 is bradycardia and above 100 is tachycardia.
- Nasal cannula oxygen flow
- A nasal cannula delivers oxygen at 1 to 6 liters per minute, producing an inspired oxygen concentration of approximately 24% to 44%.
- Sterile field border rule
- The outer 1-inch (2.5 cm) border of a sterile drape is considered non-sterile, and any item touching it or held below table level is contaminated.
- Airborne precautions requirements
- Airborne precautions require a negative-pressure room with a closed door and an N95 respirator for staff, and are used for tuberculosis, measles, and varicella.
- Contrast premedication schedule
- A patient with a prior contrast reaction typically receives prednisone 50 mg by mouth at 13, 7, and 1 hour before, plus diphenhydramine 50 mg one hour before.
- Extravasation first response
- When contrast extravasates, stop the injection, disconnect the tubing, elevate the limb, apply a compress per policy, and document and monitor the site.
- Fifteen percent rule
- Increasing kVp by 15% doubles receptor exposure, so mAs is halved; decreasing kVp by 15% halves exposure, so mAs must be doubled.
- Density maintenance formula
- The relationship mAs1 divided by mAs2 equals (SID2 divided by SID1) squared keeps receptor exposure constant when the source-to-image distance changes.
- Heat unit calculation
- Heat units equal kVp times mA times seconds times a waveform factor of 1.0 for single-phase full-wave and high-frequency generators, and about 1.35 to 1.41 for three-phase.
- Grid conversion factors
- To maintain exposure when adding a grid, multiply mAs by 2 for 5:1, 3 for 6:1, 4 for 8:1, 5 for 12:1, and 6 for 16:1.
- Anode heel effect
- X-ray intensity is lower on the anode side of the beam, so the thicker portion of the anatomy should be placed toward the cathode side.
- Magnification factor formula
- Magnification equals source-to-image distance divided by source-to-object distance; increasing object-to-image distance or decreasing SID increases magnification and reduces detail.
- Minimum total filtration
- X-ray tubes operating above 70 kVp require at least 2.5 mm aluminum equivalent total filtration, while units limited to 70 kVp require 0.5 to 1.5 mm.
- Deviation index formula
- The deviation index equals ten times the base-ten logarithm of exposure index divided by target exposure index; values within plus or minus three are acceptable.
- Quantum mottle cause
- A grainy, mottled appearance results from too few x-ray photons reaching the receptor, usually from insufficient mAs, excessive filtration, or a high speed class.
- Brightness versus receptor exposure
- Brightness is the luminance displayed on a digital monitor and is adjusted at the workstation, unlike film density, which was controlled by the exposure reaching the film.
- Subject contrast determinants
- Subject contrast depends on the thickness, density, and atomic number of the tissues being imaged, along with kVp and the presence of contrast medium.
- Rotation on PA chest
- Equidistant clavicular heads and symmetric sternoclavicular joints indicate no rotation, while asymmetry between the two sides indicates patient rotation.
- Spatial resolution definition
- Spatial resolution is the ability to image small objects that have high subject contrast, improved by small focal spots, short object-to-image distance, and no motion.
- Sternal angle landmark
- The sternal angle, or angle of Louis, lies at the T4–T5 level at the carina and is used for centering thoracic spine and chest projections.
- Iliac crest landmark
- The iliac crest corresponds to the L4–L5 level, which is also approximately the level of the umbilicus and is used to center lumbar spine and abdominal studies.
- Barium contraindication
- Barium sulfate is contraindicated when bowel perforation or obstruction is suspected; a water-soluble iodinated agent such as Gastrografin is used instead.
- PA chest positioning
- The PA chest is performed at 72 inches SID with the patient upright, chin elevated, and shoulders rolled forward to move the scapulae off the lung fields.
- Double-contrast barium enema
- Barium plus air distends the colon and coats the mucosa so small polyps can be seen; it is contraindicated in toxic megacolon and suspected perforation.
- Orbitomeatal line definition
- The orbitomeatal line runs from the outer canthus of the eye to the external auditory meatus, and the infraorbitomeatal line runs from the infraorbital margin to the meatus.
- Nonionic contrast advantage
- Nonionic, low-osmolar iodinated contrast produces fewer osmolality-related side effects and less chemotoxicity than ionic agents, but it costs more.
- Occupational dose limit
- The annual effective dose limit for radiation workers is 50 mSv (5 rem), with a lens-of-eye limit of 150 mSv and a skin and extremity limit of 500 mSv.
- Public dose limit
- The annual effective dose limit for the general public is 1 mSv (0.1 rem), and the limit for an embryo-fetus of a declared pregnant worker is 0.5 mSv per month.
- ALARA principle
- ALARA means keeping exposures as low as reasonably achievable, balancing every dose reduction measure against the image quality required for an accurate diagnosis.
- Inverse square law distance
- Radiation intensity is inversely proportional to the square of the distance from the source, so doubling the distance reduces the dose rate to one quarter.
- Dosimeter placement
- A whole-body personnel dosimeter is worn at collar level outside the lead apron, and a second badge may be worn beneath the apron to estimate dose to shielded tissues.
- Fluoroscopy cumulative timer
- Fluoroscopic equipment must signal the operator after 5 minutes of cumulative fluoroscopic exposure during a procedure so that dose can be assessed and limited.