Compressor function
The compressor raises refrigerant pressure and temperature, moving heat from the evaporator to the condenser so the A/C system can reject heat outside.
Condenser function
The condenser receives high-pressure refrigerant vapor and transfers heat to outside air, causing the refrigerant to condense into liquid.
Evaporator function
The evaporator absorbs heat from cabin air as low-pressure liquid refrigerant boils into vapor inside the evaporator core.
Expansion device function
The expansion valve or orifice tube drops refrigerant pressure and controls flow into the evaporator, separating high-side and low-side pressures.
Receiver-drier purpose
A receiver-drier on TXV systems stores liquid refrigerant and removes moisture and debris before refrigerant reaches the expansion valve.
Accumulator purpose
An accumulator on orifice-tube systems stores excess liquid refrigerant and prevents liquid from entering the compressor.
Superheat formula
Superheat equals evaporator outlet temperature minus evaporator saturation temperature; it indicates how much vapor is above boiling point.
Subcooling formula
Subcooling equals condenser saturation temperature minus liquid-line temperature; it shows how far liquid refrigerant is below condensing temperature.
Saturation pressure relationship
For a specific refrigerant, saturation pressure corresponds to one saturation temperature; changing pressure changes boiling and condensing temperature.
TXV operation
A thermostatic expansion valve modulates refrigerant flow to maintain evaporator superheat, responding to evaporator outlet temperature and pressure.
Orifice tube system control
An orifice-tube system uses a fixed restriction and cycles the compressor clutch to control evaporator temperature and prevent freeze-up.
PAG oil use
PAG oil is specified for R-134a and R-1234yf automotive systems; it circulates with refrigerant and must match the system and refrigerant.
Heater core operation
The heater core transfers heat from engine coolant to cabin air; airflow through the core determines how much heat reaches the passenger compartment.
Thermostat function
The thermostat regulates coolant flow to the radiator, helping the engine reach and maintain proper operating temperature for heating and efficiency.
Pressure cap function
The radiator pressure cap raises the cooling system boiling point and releases pressure if it exceeds the specified cap rating.
Coolant mixture purpose
A coolant mixture provides freeze protection, boil-over protection, corrosion inhibition, and heat transfer; the ratio must match manufacturer specifications.
Blend door function
The blend door varies airflow through and around the heater core, controlling cabin air temperature in manual and automatic HVAC systems.
Thermistor behavior
A thermistor changes resistance with temperature; most automotive HVAC temperature sensors are negative temperature coefficient, so resistance drops as temperature rises.
Blower resistor function
A blower resistor adds resistance in series with the blower motor to provide lower fan speeds and reduce motor voltage.
PWM blower controller
A pulse-width-modulated blower controller varies motor speed by rapidly switching power on and off, avoiding the heat of a resistor.
A/C pressure switch role
An A/C pressure switch can disable the compressor clutch or control cooling fans based on refrigerant pressure to protect the system.
Automatic climate inputs
Automatic climate control uses ambient, interior, evaporator, sunload, and sometimes humidity sensors to adjust temperature, blower, and airflow mode.
Section 609 certification
Section 609 certification is required for technicians who service motor vehicle air-conditioning refrigerant; it covers refrigerant handling and venting prohibitions.
Refrigerant recovery rule
Refrigerant must be recovered from an A/C system before opening it; venting refrigerant to the atmosphere is prohibited.
Refrigerant identification
Identify refrigerant by system label or refrigerant analyzer before recovery; mixed or unknown refrigerant requires special handling and cannot be reused as specified.
Evacuation purpose
Evacuation removes air and moisture from a sealed A/C system; achieving and holding the specified vacuum verifies readiness and helps find leaks.
Charge by weight
Charging by weight uses a scale and the manufacturer-specified refrigerant amount; this is more accurate than charging only by gauge pressure.
Performance test setup
A performance test sets engine speed, blower speed, temperature controls, and cabin conditions as specified, then compares vent temperature and pressures.
Low charge pressure sign
Low refrigerant charge commonly shows low suction and low discharge pressures, along with weak cooling and possible compressor short-cycling.
Poor condenser airflow sign
Restricted condenser airflow or overcharge commonly raises high-side pressure and can increase low-side pressure, reducing cooling performance.
Blower high-speed-only fault
If the blower runs only on high speed, suspect an open blower resistor or faulty blower controller in the lower-speed circuit.
No-heat diagnosis
No cabin heat can result from low coolant, stuck-open thermostat, clogged heater core, failed blend door, or closed water valve.