ASNT NDT III RT flashcards
ASNT NDT III RT · Build recall with a focused review session.
31 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Inverse square law
- Radiation intensity from a point source decreases with the square of distance. Doubling source-to-film distance quarters intensity, so exposure time must increase fourfold to maintain density.
- Geometric unsharpness formula
- Ug = F*t/d, where F is focal-spot size, t is object-to-detector distance, and d is source-to-object distance. Smaller focal spot or larger d reduces blur.
- Film density definition
- Density D = log10(I0/It), the logarithm of incident-to-transmitted light ratio. Density 2.0 transmits one percent of incident light through the film.
- Half-value layer
- The absorber thickness that reduces radiation intensity by half. After n half-value layers, remaining intensity equals I0 times (1/2)^n.
- Linear attenuation coefficient
- The constant mu in I = I0*e^(-mu*x) describing how strongly a material attenuates radiation per unit thickness; divided by density it becomes the mass attenuation coefficient.
- Ir-192 half-life
- Iridium-192 has a half-life of about 74 days, so source strength decays noticeably within months and exposure charts must be corrected for decay.
- Co-60 half-life
- Cobalt-60 has a half-life of about 5.3 years and emits high-energy gamma rays, giving greater penetration than Ir-192 for thick steel sections.
- Photoelectric absorption
- A low-energy interaction where a photon ejects an inner-shell electron. It dominates at low kV and produces high subject contrast in thin or low-density materials.
- Compton scattering
- Photon interaction with an outer electron that reduces energy and changes direction. It dominates at higher energies and increases scattered radiation, lowering image contrast.
- Film latitude
- The range of exposures producing acceptable density. High-latitude films show gradual density change and tolerate exposure variation but require longer exposures.
- Image quality indicator
- A penetrameter with wires or holes of known size placed on the part to verify radiographic sensitivity; the required wire or hole must be visible at the specified density.
- Lead screens purpose
- Lead foil screens absorb scattered radiation and emit secondary electrons that enhance film exposure, improving contrast and reducing exposure time.
- Source-to-film distance rule
- Increasing source-to-film distance reduces geometric unsharpness and increases the irradiated area, but requires longer exposure due to the inverse square law.
- Film characteristic curve
- A plot of density versus log exposure. Its slope (film gamma) indicates contrast; steeper slopes give higher contrast but narrower latitude.
- Scattered radiation control
- Collimation, lead screens, and backscatter shielding reduce scattered radiation reaching the film, improving contrast and image quality.
- Se-75 half-life
- Selenium-75 has a half-life of about 120 days and is used for thin-section radiography where lower energy improves contrast compared with Ir-192.
- Discontinuity versus defect
- A discontinuity is any interruption in material homogeneity; it becomes a defect only when it exceeds the acceptance criteria of the applicable code.
- Sensitivity versus resolution
- Sensitivity is the smallest discontinuity detectable; resolution is the ability to distinguish two closely spaced features as separate indications.
- Probability of detection
- The likelihood that a discontinuity of a given size is detected. POD increases with discontinuity size and depends on method, procedure, and inspector.
- SNT-TC-1A certification
- An employer-based recommended practice for qualifying and certifying NDT personnel in Levels I, II, and III; the employer's written practice governs certification.
- CP-189 certification
- ANSI/ASNT CP-189 is a standard requiring an accredited certification body; it is more stringent than SNT-TC-1A and includes additional requirements.
- Level III responsibilities
- Level III personnel develop and approve procedures, interpret codes and standards, establish acceptance criteria, and may certify other personnel.
- ALARA principle
- As Low As Reasonably Achievable: radiation exposure is minimized through time, distance, and shielding while still accomplishing the inspection.
- Occupational dose limit
- In the US, the annual whole-body occupational dose limit is typically 5 rem (50 mSv); dosimeters such as TLDs monitor cumulative exposure.
- Calibration versus standardization
- Calibration compares instrument response to a known reference traceable to a national standard; standardization checks response against a reference before use.
- UT physical principle
- Ultrasonic testing relies on reflection of high-frequency sound at interfaces where acoustic impedance differs, detecting internal discontinuities.
- MT physical principle
- Magnetic particle testing uses magnetic flux leakage at surface or near-surface discontinuities in ferromagnetic materials, revealed by applied particles.
- PT physical principle
- Penetrant testing relies on capillary action drawing penetrant into surface-breaking discontinuities, then bleed-out after developer application.
- ET physical principle
- Eddy current testing uses electromagnetic induction to generate currents in conductive materials; discontinuities alter coil impedance and signal.
- Method selection factors
- Choice among RT, UT, MT, PT, ET, VT depends on material, geometry, discontinuity type and orientation, and code requirements.
- Traceability requirement
- Measurement and calibration references must be traceable to national standards so that inspection results are reliable and comparable over time.