- Stroke volume
- The volume of blood ejected by one ventricle per beat; typically 60–100 mL at rest and equal to end-diastolic minus end-systolic volume.
- Cardiac output formula
- Cardiac output equals heart rate multiplied by stroke volume; normal resting value is roughly 4–8 liters per minute in adults.
- SA node rate
- The sinoatrial node is the dominant pacemaker, firing intrinsically at 60–100 impulses per minute and setting normal sinus rhythm.
- AV node function
- Delays conduction between atria and ventricles, allowing ventricular filling; its intrinsic escape rate is 40–60 beats per minute.
- Purkinje fibers
- Specialized conduction fibers that rapidly distribute impulses through ventricular myocardium; intrinsic firing rate is only 20–40 beats per minute.
- Coronary artery origins
- The right and left coronary arteries arise from the aortic root just above the aortic valve cusps and supply the myocardium.
- Papillary muscles
- Ventricular muscles attached to valve leaflets via chordae tendineae; they prevent mitral and tricuspid prolapse during systole.
- Small box duration
- At standard 25 mm/s paper speed, one small ECG box represents 0.04 seconds and one large box represents 0.20 seconds.
- Rate from large boxes
- For regular rhythms, divide 300 by the number of large boxes between R waves to estimate the heart rate in beats per minute.
- Six-second strip rate
- Count the number of QRS complexes in a six-second strip and multiply by ten to estimate rate, useful for irregular rhythms.
- Normal PR interval
- The PR interval measures from P-wave onset to QRS onset; normal is 0.12–0.20 seconds, prolonged in first-degree AV block.
- Atrial fibrillation
- An irregularly irregular rhythm with no discrete P waves and a fibrillatory baseline; ventricular response varies with AV conduction.
- Ventricular tachycardia
- A wide-complex rhythm over 0.12 seconds with rate typically above 100 bpm; may be pulseless and requires immediate assessment.
- Ventricular fibrillation
- Chaotic, disorganized ventricular electrical activity with no identifiable QRS complexes and no effective cardiac output; treated with defibrillation.
- Mobitz II block
- Second-degree AV block with a constant PR interval and intermittent dropped QRS complexes; considered high risk for progression to complete block.
- Asystole confirmation
- A flat-line rhythm with no electrical activity; verify leads, gain, and connections in a second lead before beginning treatment.
- V1 electrode position
- Placed at the fourth intercostal space at the right sternal border; reflects right ventricular and septal electrical activity.
- V4 electrode position
- Placed at the fifth intercostal space in the midclavicular line; V3 sits midway between V2 and V4.
- Target heart rate
- For exercise stress testing, commonly calculated as 85% of age-predicted maximum, where maximum equals 220 minus age.
- Holter monitor
- A portable device recording continuous ECG for 24–48 hours, used to correlate symptoms with rhythm during daily activity.
- Ejection fraction
- The percentage of ventricular end-diastolic volume ejected per beat; normal is approximately 55–70% by echocardiography.
- Troponin
- A cardiac biomarker released with myocardial injury; rises within hours of damage and remains elevated for several days.
- BNP
- B-type natriuretic peptide released by stretched ventricular myocardium; elevated levels support a diagnosis of heart failure.
- Synchronized cardioversion
- A shock timed to the R wave, used for unstable tachycardias with a pulse to avoid delivering energy during repolarization.
- Defibrillation energy
- For ventricular fibrillation or pulseless VT, typical biphasic energy is 120–200 joules; monophasic devices use up to 360 joules.
- Clear before shock
- Verbally announce and visually confirm that no one is touching the patient, bed, or equipment before delivering a defibrillation shock.
- Standard paddle placement
- One pad right infraclavicular near the sternum and one left lateral at the midaxillary line, forming a vector across the heart.
- Hand hygiene
- Perform before and after every patient contact and after glove removal; the primary measure for preventing healthcare-associated infection.
- Calibration standard
- ECG machines are calibrated so a 1 mV signal produces a 10 mm deflection at standard gain and 25 mm/s speed.
- Baseline wander artifact
- Slow undulation of the ECG baseline caused by respiration, patient movement, or poor electrode contact; corrected by stabilizing the patient.
- 60-Hz interference
- High-frequency artifact appearing as thickened baseline from nearby electrical equipment; reduced by checking cables and grounding.
- Lead reversal sign
- Reversed arm leads invert the P wave and QRS in lead I; precordial misplacement disrupts normal R-wave progression.
- Defibrillator checks
- Verify battery charge, self-test results, cable and paddle integrity, and documented energy output on a scheduled basis.