ASSE 12080 key terms
ASSE 12080 · Get comfortable with the vocabulary.
- Legionella pneumophila
- Related: Legionnaires' disease, Biofilm, Aerosolization
A gram-negative bacterium and the species most often linked to human legionellosis; it multiplies inside protozoa and biofilms in engineered water systems and reaches people through inhaled aerosols.
- Legionnaires' disease
- Related: Pontiac fever, Legionella pneumophila, Aerosolization
A severe form of pneumonia caused by Legionella bacteria, typically appearing 2 to 14 days after exposure to contaminated aerosols; older adults, smokers, and immunocompromised people are at highest risk.
- Pontiac fever
- Related: Legionnaires' disease, Legionella pneumophila
A mild, self-limiting flu-like illness caused by Legionella exposure that usually resolves within a few days without treatment and does not progress to pneumonia.
- Aerosolization
- Related: Legionella pneumophila, Legionnaires' disease, Biofilm
The formation and release of fine water droplets or mist that can carry Legionella bacteria into the air and be inhaled deep into the lungs.
- Biofilm
- Related: Protozoan host, Legionella pneumophila, Biocide
A community of microorganisms attached to a surface and embedded in a self-produced matrix; biofilm shields Legionella from disinfectants, heat, and shear forces and acts as a persistent reservoir.
- Protozoan host
- Related: Biofilm, Legionella pneumophila
A free-living amoeba or other single-celled organism that Legionella can infect and multiply inside; this relationship protects the bacteria from treatment and helps them persist in water systems.
- Incubation period
- Related: Legionnaires' disease, Pontiac fever
The time between exposure to Legionella and the onset of symptoms, commonly 2 to 14 days for Legionnaires' disease and shorter for Pontiac fever.
- Immunocompromised host
- Related: Legionnaires' disease, Risk assessment
A person whose immune defenses are weakened by illness, medication, or age, making them much more likely to develop severe Legionnaires' disease after exposure.
- ASHRAE Standard 188
- Related: Water management program, Hazard analysis
A consensus standard that sets minimum requirements for a building water management program to prevent legionellosis, including hazard analysis, control measures, and documentation.
- Hazard analysis
- Related: Risk assessment, Process flow diagram, Control point
A structured review of a water system to identify where Legionella could grow, multiply, or be aerosolized, and to decide which conditions need control.
- Process flow diagram
- Related: Water system survey, Hazard analysis
A schematic showing how water enters, moves through, and leaves a building system, including treatment, storage, and points of use; it supports hazard identification and control planning.
- Water system survey
- Related: Process flow diagram, Dead leg
A walk-through inspection and inventory of all water systems, equipment, and uses in a building, used to map hazards and confirm that drawings match actual conditions.
- Dead leg
- Related: Stagnation, Flushing
A section of pipe with no regular flow, allowing water to stagnate and temperatures to drift into the range that supports Legionella growth.
- Stagnation
- Related: Water age, Dead leg, Temperature stratification
Low or no water flow in a system, which lets disinfectant residuals decay, sediments accumulate, and temperatures reach levels favorable for Legionella.
- Water age
- Related: Stagnation, Temperature stratification
The length of time water resides in a system or storage tank; older water tends to lose disinfectant and warm toward growth-promoting temperatures.
- Temperature stratification
- Related: Hot water temperature control, Water age
Layering of water at different temperatures within a tank or system, which can create warm zones where Legionella grows even when bulk water appears adequately hot or cold.
- Risk assessment
- Related: Hazard analysis, Control measure
The process of evaluating the likelihood and severity of Legionella exposure at each part of a water system and prioritizing controls where risk is highest.
- Control point
- Related: Hazard analysis, Control measure, Monitoring
A point, step, or procedure where a control measure can be applied to prevent, eliminate, or reduce a Legionella hazard to an acceptable level.
- Water management program
- Related: ASHRAE Standard 188, Water management team, Program documentation
A documented, site-specific system of policies, procedures, and controls designed to prevent Legionella growth and transmission across all building water systems and devices.
- Water management team
- Related: Program manager, Water management program
A multidisciplinary group responsible for developing, implementing, and maintaining the water management program, typically including facility, engineering, maintenance, infection control, and safety representatives.
- Program manager
- Related: Water management team, Program documentation
The designated individual accountable for day-to-day coordination of the water management program, including assigning tasks, tracking monitoring, and escalating problems.
- Standard operating procedure (SOP)
- Related: Program documentation, Monitoring, Flushing
A written, step-by-step instruction describing how a task is performed consistently, such as flushing, sampling, or disinfectant dosing, including who does it and when.
- Program documentation
- Related: Water management program, Verification
Records, drawings, procedures, and logs that demonstrate the water management program is designed, implemented, and maintained as intended.
- Commissioning
- Related: Flushing, Water management program
The process of verifying that a new or modified water system is designed, installed, and operating according to specifications before it is placed into service.
- Control measure
- Related: Control point, Corrective action, Monitoring
A specific action, treatment, or design feature applied to prevent Legionella growth, reduce exposure, or keep a water system within established limits.
- Hot water temperature control
- Related: Temperature stratification, Control measure
Maintaining hot water storage at 60°C (140°F) or higher and return water at 51°C (124°F) or higher to limit Legionella growth, while managing scalding risk at points of use.
- Biocide
- Related: Hyperchlorination, Copper-silver ionization
A chemical agent such as chlorine or monochloramine used to kill or inhibit Legionella and other microorganisms in water systems.
- Hyperchlorination
- Related: Biocide, Corrective action
Temporary or targeted dosing of chlorine at elevated concentrations to disinfect a system, often used for remediation after contamination or during commissioning.
- Copper-silver ionization
- Related: Biocide, Monitoring
A water treatment method that releases copper and silver ions to inactivate Legionella; effectiveness depends on water chemistry, contact time, and regular monitoring.
- Point-of-use filter
- Related: Control measure, Corrective action
A filter installed at a fixture or showerhead to remove Legionella and sediment immediately before water is used, often used as a temporary or supplemental control.
- Flushing
- Related: Stagnation, Dead leg, Control measure
Opening outlets or drains to move fresh water through piping, reducing stagnation, biofilm, and warm water conditions that support Legionella growth.
- Corrective action
- Related: Alert limit and response limit, Monitoring
The step taken to fix a deviation, such as retreatment, repair, or flushing, and to prevent the problem from recurring when monitoring shows a limit was exceeded.
- Monitoring
- Related: Verification, Alert limit and response limit, Trend analysis
Routine measurement or observation of control parameters, such as temperature, disinfectant residual, or flow, to confirm that controls are operating within specified limits.
- Validation
- Related: Verification, Water management program
Evidence-based confirmation that the water management program, as designed and implemented, actually prevents or controls Legionella hazards under real building conditions.
- Verification
- Related: Monitoring, Validation, Program audit
Periodic checks, such as record review, sampling, or audits, that confirm the program is being followed and that control measures are achieving their intended results.
- Alert limit and response limit
- Related: Monitoring, Corrective action
Predetermined parameter values that trigger investigation or corrective action; an alert limit signals a trend toward loss of control, while a response limit requires immediate action.
- Heterotrophic plate count (HPC)
- Related: Legionella culture, Trend analysis
A general test of culturable bacteria in water that can indicate overall water quality and biofilm conditions, though it does not measure Legionella specifically.
- Legionella culture
- Related: Heterotrophic plate count (HPC), Monitoring
A laboratory method that grows Legionella from water samples on selective media, providing confirmation and quantification but requiring days to weeks for results.
- Trend analysis
- Related: Monitoring, Alert limit and response limit
Reviewing monitoring data over time to detect gradual changes, such as rising water age or falling disinfectant residual, before they become compliance failures.
- Program audit
- Related: Verification, Program documentation
A structured review of the water management program against its own procedures and applicable standards to identify gaps and drive improvement.