- Hierarchy of control
- The ranked order for managing risk: eliminate, substitute, isolate, engineer, administer, then PPE. Higher controls are more reliable and must be considered first.
- Dangerous incident notification
- A serious near miss such as a collapse, electrical contact or gas leak must be reported to the WHS regulator immediately by phone, with written notice within 48 hours.
- Confined space entry
- Entry requires a permit, gas testing for oxygen and contaminants, a standby person outside, continuous communication, and a rescue plan before anyone enters.
- Waste hierarchy
- The preferred order for managing waste: avoid, reduce, reuse, recycle, recover energy, then dispose. Plumbers apply it to offcuts, packaging, spoil and wash water.
- Silt fence purpose
- A sediment control barrier placed downslope of disturbed ground to trap soil before runoff reaches stormwater. It is inspected after rain and removed only after stabilisation.
- Backflow prevention device
- A testable fitting such as a reduced pressure zone device that stops contaminated water reversing into potable supply. It is tested annually by an accredited tester.
- Pipe volume formula
- Volume equals pi times radius squared times length. A 100 mm diameter pipe holds about 7.85 litres per metre, useful for test water and dosing calculations.
- Calculating drain fall
- Fall in millimetres equals pipe length in millimetres divided by the gradient ratio. A 1 in 60 fall over 12 metres gives 200 mm of fall.
- BSP thread
- The British Standard Pipe thread used on Australian plumbing fittings. A 15 mm (half inch) size has about 14 threads per inch and seals with tape or paste.
- PN and SN pipe ratings
- PN is the pressure rating of pressure pipe (PN12, PN15). SN is the stiffness rating of non-pressure sewer pipe (SN4, SN8) used for buried drainage.
- Height of instrument
- The reduced level of a known benchmark plus the backsight reading on that point. Subtracting a foresight from it gives the level of a new point.
- Invert level
- The level of the lowest inside surface of a pipe or pit. Cover level minus invert level gives the depth of the pipe below the surface.
- Fixture unit method
- A sizing method where each fixture is given a discharge unit value; the total load determines the required drain and vent diameters.
- Trap seal depth
- The water depth in a fixture trap that stops sewer gas entering the building. It is normally 25 to 50 mm and must be protected by a vent.
- Drainage water test
- The pipe section is sealed, filled with water to the highest point and held for at least 15 minutes to prove the joints are watertight before backfilling.
- Static pressure from head
- Pressure in kilopascals equals about 10 times the height of water in metres. A tank 10 metres above a fixture delivers roughly 100 kPa static pressure.
- Roof catchment flow
- Rainfall intensity in millimetres per hour multiplied by roof area in square metres gives litres per hour; divide by 3600 to convert to litres per second.
- First flush diverter
- A device that discards the first rainwater off a roof, which carries dust and bird droppings, before the cleaner water enters the storage tank.
- LP gas density
- Liquefied petroleum gas is heavier than air, with a specific gravity of about 1.5 to 2.0, so leaks settle in pits, trenches and low areas.
- Gas leakage test
- New gas pipework is pressure-tested with air or inert gas, usually at 1.5 times maximum operating pressure, and must hold with no pressure drop.
- Gas pipe joint restriction
- Gas pipe joints must be accessible for testing and repair. Concealed joints in wall cavities, slabs or inaccessible ducts are not permitted.
- Sensible versus latent heat
- Sensible heat changes a substance's temperature; latent heat changes its state without a temperature change, such as boiling water into steam.
- Vapour compression cycle
- The compressor raises refrigerant pressure and temperature, the condenser rejects heat, the expansion device drops pressure, and the evaporator absorbs heat.
- Refrigerant recovery
- Refrigerant must be recovered into approved cylinders and never vented to atmosphere. Handling requires a refrigerant licence and correct cylinder identification.
- Trench shoring requirement
- A trench 1.5 metres or deeper requires shoring, benching or a shield, and a competent person inspects it daily and after rain before work resumes.
- Dial before you dig
- A free service that supplies plans of underground assets before excavation. Plans must be confirmed by potholing near live services.
- Pipe bedding
- A prepared granular layer under and around a buried pipe that spreads load and protects the pipe. It is compacted before the pipe is laid to grade.
- Brazing temperature
- Brazing uses filler metal and occurs above 450 degrees Celsius, while soldering occurs below that temperature. Capillary action fills the joint.
- Flashback arrestor
- A safety device fitted to oxy-acetylene regulators and torches that stops a flame travelling back into the hose or cylinder.
- Solvent cement jointing
- PVC joints are made by cleaning, applying solvent cement to both surfaces, pushing fully home, holding briefly and wiping the bead before curing.
- Active listening
- A communication technique using paraphrasing, open questions and summarising to confirm the customer's meaning and reduce misunderstandings and callbacks.
- Variation record
- A written, signed record of a change to the agreed scope, price or program. It protects both parties and supports later claims and invoicing.