FPAS Fire Safety Assessment (FSA) flashcards
FPAS Fire Safety Assessment (FSA) · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- FPAS FSA scope
- Accreditation for assessing existing buildings and their fire protection systems against the BCA/NCC fire safety provisions and referenced Australian Standards, producing a documented assessment report.
- Assessment report mandatory content
- Scope of assessment, BCA/NCC edition applied, standards referenced, methods used, limitations, findings with evidence, and clear conclusions or recommendations for each identified non-compliance.
- Conflict of interest disclosure
- The assessor must disclose any relationship with the owner, designer, installer, or certifier that could compromise objectivity, and manage or decline the engagement where independence is affected.
- Competence boundary rule
- Matters outside the assessor's competence, such as structural adequacy or complex fire engineering, must be identified in the report and referred to a suitably qualified practitioner.
- CPD record keeping
- Maintaining a log of continuing professional development with dates, hours, topics, and relevance to fire safety assessment, available for audit by the accreditation body.
- Evidence traceability
- Recording inspection dates, attendees, instruments and calibration status, photographs, and document references so each conclusion in the report can be independently verified.
- Confidentiality obligation
- Client and building security information is not disclosed without consent, except where required by law or by the accreditation body's audit or disciplinary process.
- Peer review purpose
- Independent technical review of an assessment report to confirm methodology, evidence sufficiency, and the consistency of conclusions with the cited code provisions and standards.
- BCA fire safety Performance Requirements
- The eight mandatory outcomes CP1 to CP8 covering structural stability, fire spread between and within buildings, exits, brigade access and equipment, evacuation, and fire system reliability.
- Deemed-to-Satisfy provisions
- Prescriptive BCA rules for building class, rise in storeys, and construction that, if fully met, are deemed to satisfy the relevant Performance Requirements without further analysis.
- Performance Solution
- A design or assessment route that demonstrates compliance with Performance Requirements by analysis or comparison, requiring documented verification methods and acceptance criteria.
- Fire-resistance level
- An FRL expressed as structural adequacy, integrity, and insulation in minutes, applied to building elements to limit fire spread and maintain structural stability for the required period.
- Fire compartment
- A space enclosed by fire-resisting construction that limits fire and smoke spread to a defined area for a specified period, protecting exits and adjacent occupancies.
- Fire door verification
- Check the door's fire rating matches the opening, that it self-closes and latches fully, and that hold-open devices release on alarm or smoke detection.
- Penetration sealing
- Fire-rated seals around pipes, cables, and ducts passing through fire-resisting elements, verified for correct system, installation, and recorded certification.
- Automatic fire detection
- Smoke, heat, or other detectors linked to an alarm system that provides early warning to occupants and can initiate suppression, smoke control, or door release.
- Sprinkler system verification
- Confirm coverage matches the hazard class, heads are unobstructed and correctly spaced, control valves are open and monitored, and the system is maintained under AS 1851.
- Hydrant and hose reel check
- Verify hydrant coverage, booster location and access, hose reel reach and condition, and that flow and pressure testing records demonstrate the system performs as designed.
- Exit travel distance
- The maximum permitted distance from any point on a floor to a required exit, set by the DTS provisions according to building class and whether the path is sprinkler protected.
- Number of required exits
- Determined by occupant number, floor area, and building class under the DTS provisions, with each exit providing an alternative path not compromised by a single fire event.
- Exit width calculation
- Required aggregate exit width is derived from occupant capacity using the DTS per-person allowances, adjusted for stairways and level surfaces, and checked for obstructions.
- Fire-isolated stair
- A stairway enclosed in fire-resisting construction with protected discharge, providing a safe egress route that resists smoke and fire ingress for the required period.
- Smoke control system
- A smoke exhaust or pressure differential system that maintains tenable conditions in escape routes by removing smoke or holding back smoke with pressure and airflow.
- Emergency lighting
- Battery-backed lighting that maintains illumination of exits and paths of travel for the specified duration when normal supply fails, verified by discharge testing records.
- Exit signage
- Illuminated and directional signs identifying exits and the direction of travel, verified for visibility, correct pictograms, and operation on emergency power.
- Building classification
- Class 1 to 9 categorisation by use and occupancy, such as residential, commercial, industrial, or assembly, which determines the applicable DTS fire safety requirements.
- Rise in storeys
- A defined count of storeys used with building class to set construction requirements, fire resistance, and egress provisions under the DTS provisions.
- AS 1851 maintenance
- The Australian Standard setting routine servicing frequencies and records for fire protection systems, used to verify ongoing reliability of installed systems.
- Fire brigade access
- Vehicular access, hardstand, and hydrant booster arrangements that allow the fire service to reach and supply the building, verified against DTS provisions.
- Fire control panel location
- The fire indicator panel and controls must be located, identified, and accessible as required so the fire service can confirm and manage system status on arrival.
- Passive versus active systems
- Passive systems resist fire through construction such as FRLs and compartmentation; active systems detect, suppress, or control smoke and require power and maintenance.
- Occupant capacity check
- Verifying the permitted number of occupants against floor area and egress capacity so that exits, stairs, and discharge paths can accommodate the assessed population.